Calcium Ion concentration 1000ppm, PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy.
With manual and automatic temperature compensation functions, PCa Measurement range 0.00-6, resolution up to 0.01 pCa, lightweight and portable only 1.5kg, while displaying pF value and calcium Ion concentration value.
With 1% F. S Measurement accuracy and automatic temperature compensation function, it supports 500 sets of Data storage and a variety of Ion concentration unit selection, equipped with large screen backlight display and automatic ElectRode diagnostic system.
Measurement range 200-600ppm, accuracy +/- 6% reading, LED Illuminant 610nm, automatic shutdown function, suitable for seawater calcium Ion concentration detection.
ElectRode filling solution suitable for ammonia Gas sensing electRode maintenance, capacity 480mL, calcium ion type design to ensure measurement accuracy, prolong ElectRode life.
Optimized for calcium ion detection, 250ml Encasement meets the needs of routine use, ensures ElectRode Response Stability by adjusting the ion strength, and improves the Reliability of detection data.
Designed for Calcium Composite ElectRode, 250ml Standard Encasement is provided to ensure ElectRode calibrating accuracy and long-term Stability for a variety of analytical scenarios.
Measurement accuracy of +/- 1% F. S with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation to ensure measurement Stability and accuracy.
Specially optimized for fluorocalcium ion composite ElectRode, providing stable reference potential, 250ml Encasement meets long-term use requirements, suitable for a variety of ion detection scenarios.
Using composite ElectRode design, equipped with 60mL reference filling solution and calibrated solution, BNC interface compatibility, Measurement range, suitable for a variety of water quality analysis scenarios.
Dual channel LED digital display, using silicon Photocell, photovoltaic cell detection, measurement Repeatability relative standard deviation ≤ 2%, can simultaneously detect various elements of potassium, sodium, lithium, calcium and barium, the sample amount is small and Sensitivity is high.
Colorimetric measurement using calcite method, Calcium Hardness Measurement range of 0.00~ 2.70 mg/L, providing 100 tests, compatible with a variety of Photometers.
Silicon Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium detection limit of 0.004mmol/L and 0.008mmol/L, support lithium calcium detection function, small sample and Sensitivity.
Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium detection limit of 0.004mmol/L and 0.008mmol/L, Response Time is less than 8 seconds, support lithium calcium detection function.
Silicon Photocell, photovoltaic cell detection to ensure accurate and stable measurement, can simultaneously detect potassium, sodium, lithium, calcium and barium elements, small sample Sensitivity, with automatic ignition and flameout protection function safe and reliable.