Wireless Bluetooth Silver Ion Meter

The wireless Bluetooth silver ion meter detects the concentration of silver ions in a solution using a silver ion-selective electrode, converts electrical signals into digital data, and transmits them via Bluetooth to a mobile phone or computer. It is used to monitor silver content in fields such as water quality, electroplating solutions, and photosensitive materials, facilitating on-site rapid detection and recording.
Selection
When selecting, consider that the measurement range should cover the actual sample concentration, the precision should meet the detection requirements, Bluetooth compatibility with common devices, electrode lifespan and calibration frequency affect usage costs, the protection rating should suit the operating environment, and the data export function should align with recording needs.

Terms

Standards

Instruments

Supports wireless Bluetooth connection to mobile devices, provides 5 Ion concentration Measuring methods, Measurement accuracy +/- 1% F. S, with 2 to 5 point calibrating and manual temperature compensation function to ensure accurate and reliable data.

$ 733.00

Support wireless Bluetooth connection to Android devices, provide 5 point calibrating and 8 calibrating liquid selection, Measurement accuracy of +/- 0.5% F. S, with automatic end point locking and temperature compensation functions to ensure stable and reliable data.

$ 733.00

Support 0.00001~ 1mol/L wide range measurement, accuracy of +/- 0.5% F. S, with 5 point calibrating, ElectRode management and manual temperature compensation functions, can connect Bluetooth devices to achieve Multi-ParaMeter measurement.

$ 733.00

Supports 5 Ion concentration Measuring methods, providing 2 to 5 point calibrating and 8 concentration calibrating points optional, Measurement range 0.0000001~ 1mol/L, with automatic end point locking and manual temperature compensation function.

$ 733.00

Measurement accuracy of +/- 1% F. S, support 5 point calibrating and manual temperature compensation, with automatic end point locking and limit alarm functions, can be connected to a variety of ion selective ElectRode.

$ 733.00

Measurement accuracy of +/- 1% F. S, 5 point calibrated and a variety of Ion concentration units, ElectRode management and temperature compensation functions ensure stable and reliable measurement.

$ 733.00

Supports 5 Ion concentration Measuring methods, Measurement accuracy of +/- 1% F. S, 2 to 5 point calibrating and manual temperature compensation functions to ensure accurate and reliable measurement data.

$ 733.00

Effective transmission distance of 10 Meters, using Bluetooth wireless transmission technology, equipped with RS-232 software CD, to achieve wireless data communication between measurement equipment and computer.

$ 122.00

Measurement range 0.000005~ 1mol/L, accuracy +/- 0.5% F.S. ElectRode management, temperature compensation and automatic end point locking function ensure stable and reliable measurement.

$ 733.00

The mobile sleeve liquid fluid design, equipped with silver ion trapping trap, Glass film resistance is less than 50MΩ, and the shell is made of lead-free Glass to ensure stable measurement and durability.

$ 469.00

The pRoduct concentration 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy.

$ 135.00

Split design, tablet PC control, Bluetooth 4.0 wireless communication, Measurement range Ra 025-12.5 μm, support for a variety of Sensors and auxiliary clamping devices, compact body to adapt to complex working conditions.

$ 1332.00

Support 5 point calibrating and 8 kinds of calibrating liquid, Measurement range 0.00000001~ 0.1mol/L, ElectRode management and manual temperature compensation function to ensure measurement Stability.

$ 733.00

Designed with a ceramic liquid complex section and equipped with silver ion trap technology, the membrane resistance is less than 50MΩ, and the lead-free Glass housing ensures durability for wide temperature range measurement.

$ 296.00

Using mobile sleeve liquid complex and silver ion trap structure, the film resistance is less than 50MΩ, Measurement range covers 0-11pH, temperature tolerance 0-80 ℃, to ensure stable and accurate PH detection.

$ 296.00

Articles

Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
The coating machine applies a conductive layer (silver nanowires) for flexible display screens onto a PET substrate.
This article introduces the technique of coating a silver nanowire conductive layer on PET substrates using a film applicator. Silver
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Key operational points for determining chloride ion content in water using automatic potentiometric titrators
This article introduces a method for measuring chloride ions in water using an automatic potentiometric titrator. It is based on silver nitrate titration, where the endpoint is automatically determined by a sharp change in electrode potential, offering greater accuracy and higher automation compared to traditional methods.
Preparation of silver nanowire transparent conductive films by the wire bar coating method
The preparation of silver nanowire transparent conductive films using a coating method is an efficient and scalable production process. This article systematically elaborates on the technology from aspects such as principles, materials, processes, performance characterization, and standards.
How to achieve high uniformity in silver nanowire transparent conductive films through wire rod coating
This article introduces how to prepare uniform silver nanowire transparent conductive films using the wire rod coating technique. These films, which use silver nanowires as the conductive material, exhibit high transparency and conductivity, making them suitable for applications such as touch panels.