Powder Particle Detection and Analysis System

Powder particle analyzers measure particle size distribution through laser diffraction or image analysis. They are used to control powder quality, monitor the fineness of raw materials in the pharmaceutical and coating industries, and ensure product consistency.
Selection
Select laser or imaging method based on sample characteristics; ensure the measurement range covers the actual particle size; evaluate whether dry or wet sample processing is required; confirm that the software meets industry-standard data output requirements.
Optical inspection principle
test principle
Special purpose

Terms

Standards

Instruments

Measurement range 0.5-3000 μm, maximum resolution 0.1μm, support more than 30 image analysis functions, Particle size distribution and morphology analysis.

$ 5237.00

The image method is used to analyze the particle morphology and particle size, the test range is 1~ 3500 μ m, the system magnification is 4000 times, the automatic segmentation success rate exceeds 93%, and paraMeters such as length-diaMeter ratio and sphericity can be counted.

$ 5366.00

Test range 0.5~ 3000μm, Maximum magnification 4000 times, can analyze the number of particles, area, circumference, diaMeter, aspect ratio and other distribution data, support a variety of formats of test report output.

$ 6205.00

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

The image method is used for particle morphology analysis, the measurement range is 0.1~ 3000μm, the total magnification is 8000 times, and the automatic segmentation and measurement of various geometric paraMeters are supported, and the operation is efficient.

$ 8949.00

The image method is used for particle morphology analysis, the measurement range is 0.1~ 3000 μ m, the total magnification is 8000 times, and it has the functions of automatic segmentation and measurement of various geometric paraMeters.

$ 12176.00

The injection limited bottom surface method is used to directly measure the angle of repose, the funnel taper is 60 ° +/- 0.5 °, and the outflow diaMeter is 5mm, which is suitable for powder flowability analysis of different particle sizes and shapes.

$ 545.00

100L/min Sampling flow rate and six particle size channel detection, equipped with long life laser Illuminant and imported air pump, support Touchscreen operation and USB data export function.

$ 10578.00

Image segmentation technology is used to process overlapping dust and maintain particle prototype; Measurement range is 0.1~ 3000μm, repeatability error ≤ +/- 1%; support custom particle size classification and various image processing methods.

$ 9998.00

With six-channel particle size detection and 2.83L/min Sampling flow rate, using laser Illuminant life of over 30,000 hours, support UCL calculation and Built-in Printer, AC-DC dual-use can work continuously for more than 6 hours.

$ 848.00

Using 50L/min Sampling flow rate and six particle size channel synchronous detection, equipped with semiconductor laser Illuminant and Touchscreen control, built-in thermal printer supports real-time data output, Continuous Operating Time up to 5 hours.

$ 8461.00

With 3000 times/min and 6000 times/min two vibration frequencies, the amplitude can be continuously adjusted between 0mm and 3mm, supporting three modes of subtle vibration, intermittent vibration and continuous vibration, suitable for ≤ 325 mesh material analysis.

$ 811.00

With 6-channel synchronous detection capability, maximum sampling concentration of 35000 pcs/L, using semiconductor laser Illuminant life of 10 years, built-in battery life of more than 5 hours and support data export printing.

$ 1501.00

It can simultaneously measure more than 10 physical paraMeters such as angle of repose and tap density. The vibration frequency is 300 rpm, and the repeatability error is ≤ 3%. It supports a variety of national standard test methods to meet the needs of comprehensive characteristic analysis of powder.

$ 5528.00

Can test flowability, Angle of Peace and Loose Bulk Density, equipped with 30ml stainless steel measuringflask and double powder plate, funnel diaMeter can be selected 5mm or 2.5mm, for precise control of powder mass.

$ 993.00

Articles

How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
Blue-style grinder achieves efficient grinding of ink fineness.
The basket mill is a type of wet grinding equipment used in fine chemical fields such as ink production. It utilizes a high-speed rotating impeller to drive grinding media, generating shear and impact forces on the slurry, thereby dispersing pigment particles and reducing their fineness.
Application of High-Speed Disperser in the Preparation of Water-Based Inks
This article introduces the application of a high-speed disperser in the preparation of water-based inks. It first explains the working principle of the equipment, which involves generating shear forces through high-speed rotation to disperse particles.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.
Which is more accurate for measurement: the scattering method or the transmission method in turbidimeters?
The article compares two methods for measuring turbidity: the scattering method and the transmission method. The choice of method depends on the turbidity range of the sample, particle characteristics, and measurement standards. Both methods have their respective applicable scenarios, and accuracy depends on the actual application conditions.
Core Differences and Selection Guide for Pulpers and Refiners
Both the beater and the refiner are equipment for processing materials, but their core functions differ. When selecting the appropriate machine, it should be based on the characteristics of the material: choose a beater for fiber treatment and a refiner for particle refinement, while also taking into account process requirements and operational costs.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Porosity Control in the Preparation of Porous Coatings During the Blade Coating Process
Doctor blade coating is a wet coating technique widely used for preparing functional coatings, which involves uniformly applying a slurry containing solid particles (such as ceramics, polymers, or metal oxides) onto a substrate, followed by drying and heat treatment to form the coating.
The Key Role of Apparent Density Meters in Assessing Powder Flowability.
This article discusses how a bulk density tester is used to evaluate the flowability of powders. Powder flowability is crucial in production. The instrument measures the bulk density and tapped density, then calculates the compressibility index and Hausner ratio. These two parameters directly reflect the quality of powder flow.
The main issue with using a Ubbelohde viscometer is that 90% of capillary blockages are caused by inadequate sample filtration.
More than 90% of capillary blockage in Ubbelohde viscometers during measurement is due to inadequate sample filtration. Minute particles or gels in the sample tend to adhere to or become trapped when flowing through the narrow capillary, leading to abnormal flow rates and affecting measurement accuracy.
The combination of bulk density tester and angle of repose tester provides a one-stop solution for powder flowability testing.
This article introduces a method for comprehensively evaluating powder flowability in powder engineering by combining the use of an apparent density tester and an angle of repose tester. Apparent density reflects the packing characteristics of the powder, while the angle of repose indicates its ease of flow.
An article tells you how to choose a fineness gauge.
This article introduces how to select and use a grind gauge. It is a tool for measuring particle size in coatings and inks. When selecting one, the first step is to choose the appropriate range based on the estimated fineness of the sample (commonly 0-50 µm or 0-100 µm).