Atmospheric Environment Monitoring Instrument

The atmospheric environment monitor collects data on particulate matter and gas concentrations in the air through sensors, processes the signals via circuits, and displays the readings. It is used for real-time monitoring of air quality and recording pollution levels in areas such as factory emissions and urban environments.
Selection
When selecting, consider the matching of monitoring parameters with requirements, sensor accuracy and anti-interference capability, equipment protection level suitability for the installation environment, compatibility of data output interfaces with existing systems, and alignment of maintenance cycles and consumable costs with usage conditions.

Terms

Standards

Instruments

Maximum temperature of 1700 ℃, Furnace volume of 12 liters, using silicon molybdenum Rod heating and aluminum oxide fiber Furnace to ensure uniform heating and durability, support inert or reducing gas environment, suitable for high temperature material processing.

$ 5979.00

Operating temperature up to 1700 ℃, Furnace volume 80L, aluminum oxide fiber Furnace and double chill down system, support inert and reducing atmosphere environment material sintering treatment.

$ 7867.00

Using 525nm LED Illuminant, Measurement range 0.0-30 ppm, accuracy +/- 1.0ppm, based on amino acid method to achieve high Sensitivity phosphoric acid salt detection, suitable for a variety of water quality environments.

$ 215.00

Adopting double-decked Vacuum Reinforced Glass observation window and SUS304 stainless steel inner box, the temperature control accuracy reaches +/- 0.5 ℃, supports program test and Data storage function, and meets the strict environment Reliability verification requirements.

$ 3333.00

Using memory metal alloy material, temperature measurement range -20~ 50 ℃, humidity measurement range 0~ 99% RH, aging resistance and accurate Measurement, suitable for a variety of environment monitoring needs.

$ 94.00

Measurement range 0.0-15 ppm, accuracy +/- 0.3ppm +/- 5% reading, using LED@525nm Illuminant, based on amino acid method for rapid detection of phosphoric acid salts, easy to operate and suitable for laboratory and field.

$ 209.00

Vacuum environment significantly reduces the boiling point of liquid, suitable for heat-sensitive substances; drying Temperature range RT + 50~ 200 ℃, Vacuum Level < 133Pa; inert conditions prevent oxide explosion, powder sample stability does not move.

$ 1003.00

The highest temperature is 1400 ℃, the Furnace volume is 4.5L, and the aluminum oxide fiber Furnace and silicon carbon Rod heating elements are used to support the inert gas environment and ensure the uniform and stable sintering of the material.

$ 3720.00

Using double-decked Vacuum Glass observation window and SUS304 stainless steel inner box, temperature control accuracy +/- 0.5 ℃, support programmed test and multi-stage programming, with Data storage and communication functions to meet the demanding environment testing needs.

$ 3220.00

Maximum temperature up to 1700 ℃, Furnace volume 36L, using aluminum oxide fiber material and silicon molybdenum Rod heating element, equipped with a chill down system to ensure sealing performance, support inert or reducing gas environment sintering.

$ 6851.00

It can be tested in the sewage environment, the speed range is 0.01-10 m/s, the error is less than or equal to 1.5%, the measuring Rod positioning measurement method is adopted, the structure is simple and light, the Degree of automation is high and stable and reliable.

$ 612.00

Using environmentally friendly refrigerant, Temperature Uniformity +/- 1 ℃, humidity fluctuation +/- 5% RH, equipped with intelligent Touchscreen controller and ultrasonic humidifier, supports programmable control and remote monitoring interface to ensure stable and reliable experimental environment.

$ 5529.00

Non-contact Sensor with long life and two Measurement ranges (100 to 55000 μS/cm). The enclosure is made of Acetal Resin, which is resistant to seawater corrosion and supports monthly on-site calibrating for accuracy, with a maximum operating depth of 70 Meters.

$ 1719.00

Operating temperature of 1400 ℃, Furnace volume of 36 liters, aluminum oxide fiber Furnace and double chill down system, support material sintering process in inert gas environment.

$ 4914.00

Adopt cascade refrigeration system, Temperature range -40~ 150 ℃, humidity control range 20~ 98% RH, with 1000 segment program capacity and automatic calculation function, support PC link and network monitoring.

$ 6593.00

Articles

How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Transverse Burst Strength Tester for the Evaluation of Impact Resistance of Corrugated Cardboard
This article explains how a lateral bursting strength tester is used to evaluate the impact resistance of corrugated cardboard. It measures the energy absorbed by the cardboard at the point of rupture using the pendulum impact principle, requiring the preparation of specimens according to standards and the control of environmental conditions during testing.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
Application of Coating Rate Cardboard in the Determination of Coating Rate for Architectural Coatings
Coating rate card paper is a standardized substrate used to determine the spreading rate of architectural coatings. It features a smooth surface and stable parameters, which help minimize the influence of substrate variations and environmental factors associated with traditional methods.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Ozone Aging Test Chamber Evaluates Crack Resistance of Rubber
This article introduces how an ozone aging test chamber is used to evaluate the crack resistance of rubber. Ozone is a common factor that causes rubber aging. The test chamber simulates an ozone-containing environment, applies strain to rubber samples, and accelerates their aging process.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.