Small Circulation Corrosion Test Chamber

The small-cycle corrosion test chamber accelerates the corrosion of samples under alternating conditions by simulating changes in environmental factors such as temperature, humidity, and salt spray. It is used to evaluate the corrosion resistance of materials in dynamic environments and is commonly employed in quality testing for products such as metal coatings and electronic components.
Selection
When selecting, consider the box dimensions to match sample requirements, the temperature range to cover testing standards, the control system for ease of operation, corrosion-resistant materials with good sealing, reliable after-sales service from the brand, and a price that fits the budget.

Terms

Standards

Instruments

Adopt 8mm thickness PVC reinforced rigid plastic plate shell, sulfur dioxide concentration 10~ 30ppm adjustable, equipped with corrosion-resistant silicone airway and alkali solution exhaust gas treatment system, Temperature Uniformity ≤ +/- 2 ℃.

$ 15581.00

8Mm thick PVC reinforced rigid plastic plate box, sulfur dioxide concentration adjustment range of 600~ 10000ppm, equipped with corrosion-resistant silicone airway and alkali solution exhaust gas treatment system, temperature control accuracy +/- 0.5 ℃.

$ 15823.00

Using corrosion-resistant PVC material and titanium alloy heating tube, Temperature Uniformity ≤ +/- 2 ℃, equipped with sulfur dioxide flowMeter and alkali waste gas treatment system to ensure test accuracy and environment safety.

$ 15823.00

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

Adopt hot air circulation system to ensure uniform temperature, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 2%. Inner Chamber dimensions 750 * 600 * 500mm, stainless steel liner corrosion resistance, shelf height adjustable for easy sample access.

$ 651.00

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

The adapter adopts stainless steel sample Chamber removable cleaning, the temperature control accuracy of water Bath jacket reaches 0.1 ℃, the sample volume is only 2-16 ml, and the Measurement range covers 2-26600000MPas/cp.

$ 2300.00

Adopt ALLCOLD equilibrate refrigeration technology to support automatic defrosting and continuous operation; ALLFLOW air circulation system ensures rapid temperature recovery and stability; light intensity is adjustable from 0 to 15000Lx, Temperature Fluctuation +/- 1 ℃, to meet the needs of multi-stage programming control.

$ 3974.00

Suitable for laboratory sampling test, high corrosion resistance, can measure a variety of material density, with sampling test type for liquid special anti-corrosion accessories.

$ 123.00

PTFE material pump head and composite diaphragm, strong corrosion resistance, maximum Flow rate 35L/min, Ultimate vacuum degree 15-20mbar, no pollution and maintenance, low noise operation, suitable for corrosion environment.

$ 1066.00

The equipment adopts white water circulation system, equipped with electric sizing and aeRodynamic bubble homogenizing functions, the diaMeter of the extraction cylinder is 200mm and the capacity is 8 liters. It supports external vacuum suction, and the volume is small and easy to move.

$ 1493.00

Brushless DC motor with strong magnet, strong stirring force; Maximum stirring capacity of 3 liters, Speed range up to 1500 rpm; Corrosion resistant shell and stainless steel face to ensure long-term stable operation.

$ 162.00

Inner Chamber dimensions 500 * 600 * 750mm, Volume 225L, Temperature Fluctuation +/- 0.5 ℃, using air duct circulation system to automatically discharge water vapor, improve Temperature uniformity, support RS485 interface connection recorder.

$ 1069.00

PTFE material pump head and composite diaphragm, Maximum Flow rate 20L/min, Ultimate vacuum degree 15-20mbar, with anti-corrosion, low noise, overheating protection function, suitable for corrosion environment.

$ 916.00

Adopt 4mm small diaMeter design, suitable for surface or small area measurement; Repeatability Delta E * ab < 0.05 to ensure Measurement accuracy; Horizontal structure is small in size, comfortable and stable to hold.

$ 1203.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.