Insulation Water Damp Heat Test Chamber

The Insulation Water Damp Heat Test Chamber generates saturated steam by heating water to create a constant temperature and humidity environment in an enclosed space. The chamber body is constructed of stainless steel to prevent corrosion. Test samples are exposed to high temperature and high humidity conditions to observe changes in the performance of insulation materials. It is primarily used for moisture resistance testing of electrical and electronic products and circuit boards, simulating the effects of humid climates on insulation layers.
Selection
When selecting, consider matching the working chamber size to the sample volume, with a temperature range covering 40-100℃ and a fluctuation of ±0.5℃. The humidity range should be at least 20-98% RH, with a uniformity of ±3% RH. The inner chamber must be made of 304 stainless steel and include functions for water shortage protection and condensation drainage. The control system should display real-time temperature and humidity curves and comply with basic standards such as GB/T2423.3.

Terms

Standards

Instruments

Adopt high temperature fan and special air duct to ensure temperature uniformity, equipped with low speed turntable; Temperature range RT + 10~ 200 ℃, uniformity +/- 2 ℃, support 3-100 times/h ventilation volume adjustment.

$ 6044.00

Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable and hot air circulation system to ensure stable and uniform temperature in the working room.

$ 8045.00

The use of high temperature fan and special air duct to achieve uniform heating, equipped with low-speed turntable to ensure uniform heating of the sample, Temperature Fluctuation control within +/- 0.5 ℃, ventilation can be adjusted within the range of 3-100 times/hour.

$ 6560.00

Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable, support 3~ 100 times/h ventilation volume adjustment, to meet a variety of aging test needs.

$ 4463.00

150W Philips infrared lamp, peak wavelength 950nm, temperature measurement accuracy +/- 0.5 ° C, insulation accuracy +/- 2%, can quickly compare the insulation performance of different materials, the test time is only 1 minute.

$ 264.00

6-Channel design supports multi-directional temperature monitoring, can work for 60 minutes in a 500 ° C environment, using nano-aerospace environmentally friendly heat insulation materials, K-type Thermocouple ensures +/- 0.3 ° C High Accuracy measurement, effectively solving color difference and curing problems.

$ 1451.00

The heat sealing performance was determined by hot pressing sealing method, the temperature control accuracy was +/- 0.2 ℃, the heat sealing time was 0.1~ 999.9s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured safety.

$ 1603.00

The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.

$ 1200.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.

$ 3015.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, independent temperature control of upper and lower heat sealing heads, good thermal conduction effect of brass heat sealing knife, double-decked thermal insulation design to ensure safe use.

$ 1764.00

Adopt stainless steel liner and hot air circulation system, Temperature Uniformity +/- 2 ℃, ventilation time 3min-100h adjustable, equipped with low speed turntable and multiple safety protection devices.

$ 4850.00

150W Philips infrared lamp, double lamp temperature non-uniformity of 2C °, unilateral temperature Measurement accuracy +/- 0.5 ° C, can compare the heat insulation effect of two materials at the same time and display the temperature difference in real time.

$ 248.00

It is compacted by 14,000 tons of hydraulic press, with a density of 1.5-1 g/cm ³ and a flexural strength of air drying ≥ 21Mpa. It has A-class non-combustibility, sound insulation and heat insulation, water resistance and moisture resistance performance, convenient construction and green environmental protection.

$ 180.00

Adopt stainless steel mirror liner and ultra-fine fiberglass insulation, Temperature Fluctuation ≤ +/- 0.5 ℃, uniformity ≤ +/- 2 ℃, equipped with large screen Touchscreen and automatic calculation function, improve temperature and humidity control accuracy and operation convenience.

$ 8820.00

Adopt stainless steel mirror liner and ultra-fine fiberglass insulation cotton, equipped with French Taikang fully enclosed Compressor, Temperature Fluctuation ≤ +/- 0.5 ℃, support 100 sets of program editing and RS-232/485 communication, improve test stability and convenience.

$ 6560.00