Fast sterilizing in ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, the built-in over-temperature protection device, and the stainless steel liner container ensures safety and durability.
Capacity 1000ul, Minimum Encasement 500 pcs/pack, Sterile design to ensure experimental accuracy, suitable for a variety of Pipette use.
The 10ul capacity specification is used with the standard Pipette, and each pack of 1000 packs meets the needs of batch experiments. The transparent material is convenient for observing the liquid level.
Capacity 10ml, minimum Encasement 100 pcs/pack, sterile independent Encasement to ensure experimental cleanliness, conical design to ensure airtightness, suitable for a variety of brands Pipette use.
Range 1-5ml, accuracy error +/- 0.50%, nozzle ejector removable and high temperature and high voltage disinfection, easy to clean and maintain, light operation.
Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, 3 minutes to quickly restore the set concentration; equipped with high temperature heating and humidity sterilizing function, effectively eliminate microbial contamination, circulating fan automatic speed control to protect the sample.
Imported Infrared Sensor, CO2 concentration control accuracy of +/- 0.1%, restore the set concentration within 3 minutes after opening the door; equipped with high temperature heating and humidity sterilizing system, can completely eliminate microbial pollution, circulating fan speed automatic adjustment to avoid sample volatilization.
Using Infrared Sensor to control CO2 concentration, it can be restored to 5% set value within 3 minutes after opening the door for 30 seconds; equipped with 90 ℃ high temperature heating and humidity sterilizing system, fully sterilized for 18 hours; HEPA Filter makes the air mass in the box reach 100 clean level.
Using Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, equipped with high temperature heating and humidity sterilizing function, CO2 concentration is restored within 3 minutes after opening the door, and the circulating fan automatically adjusts the speed to avoid sample volatilization.
The 15-hole design is suitable for 10ml suction heads, which are specially matched for HYD-1WB Pipette to ensure accurate and stable pipetting process and improve experimental operation efficiency.
The range is 0.5~ 10 μL, the accuracy error is as low as +/- 1.00%, the nozzle ejector can be removed and supports high temperature and high voltage disinfection, which is easy to clean and maintain, and the operation is light and the reading is clear.
Continuously adjustable micro-pipetting, range 10-100ul, accuracy error +/- 0.80%, nozzle ejector removable for high temperature and high voltage disinfection cleaning and maintenance.
The 96-hole design is suitable for a variety of Pipette models, and the 200ul capacity meets the needs of routine experiments to ensure that the suction heads are neatly stored and easy to use.
The 96-hole design is adopted, with a capacity of 10ul, and it is suitable for HYD-0.1B/0.5B Pipette to ensure stable placement and quick access of the suction head, which improves the efficiency and accuracy of the experiment.
The 60-hole design is suitable for 1ml suction heads, which are specially optimized for HYD-100B Pipette to ensure stable storage and quick access of the suction heads, and improve the experimental efficiency.