Powder Molding Machine

The powder former compresses loose powders into blocks of specified shapes by applying pressure, facilitating subsequent testing or usage. It utilizes molds and a pressure system to complete the forming process and is applied in sample preparation for industries such as coatings and plastics.
Selection
When selecting a powder compactor, consider the sample characteristics, the required pressure range for forming, and the compatibility of mold dimensions with testing requirements. Pay attention to the pressure accuracy and control method of the equipment to ensure operational safety and maintenance convenience.

Terms

Standards

Instruments

The extrusion molding process is used to ensure continuous wire, the film thickness is precisely controlled by 20μm, the application width is 250mm to meet various needs, and the 304 stainless steel material is durable and easy to clean.

$ 157.00

Adopt integrated injection molding measurement frame and transparent water Tank, anti-corrosion and drop resistance; density readability 0.001g/cm ³, Capacity 300g; support a variety of liquid media, rapid testing suitable for field applications.

$ 348.00

Suitable for high voltage molding sand test, compression stroke 2.50mm, load 1500g, with average calculation and MAX Maximum latch function, support USB and Bluetooth data communication.

$ 328.00

Can test flowability, Angle of Peace and Loose Bulk Density, equipped with 30ml stainless steel measuringflask and double powder plate, funnel diaMeter can be selected 5mm or 2.5mm, for precise control of powder mass.

$ 993.00

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

Standard funnel method for metal powder flowability measurement, equipped with 2.5mm and 5mm pore diaMeter stainless steel funnel, can accurately measure 50g powder flow time to +/- 0.01s, suitable for powder testing such as cemented carbide.

$ 525.00

Four 25 ° inclined quartz Glass baffles are used to guide the powder flow and are equipped with a 25 +/- 0.05ml standard cylindrical Cup to achieve a loose powder state through natural gravity, ensuring the accuracy and Repeatability of density testing.

$ 687.00

The injection limited bottom surface method is used to directly measure the angle of repose, the funnel taper is 60 ° +/- 0.5 °, and the outflow diaMeter is 5mm, which is suitable for powder flowability analysis of different particle sizes and shapes.

$ 545.00

Double pulse Back flushing automatic powder cleaning, Laminating filter accuracy of 0.3 microns, powder gas separation efficiency, stainless steel material is durable, color change operation is simple, improve dust recovery efficiency.

$ 1655.00

Using fixed funnel method to measure powder flowability, equipped with 10mm inner through Glass funnel and 0-100mm scale struts, can accurately measure cone height, meet the requirements of Pharmacopoeia and ISO standards.

$ 535.00

Using high frequency principle, Measurement range 0-99.9%, resolution 0.1/0, Response Time 1 second, probe type Sensor can penetrate deep into the material internal measurement, backlight LCD display clear and low consumption.

$ 233.00

Rotation speed control is accurate and synchronization performance is good; the height of the casting roller can be adjusted to adapt to different solution strength materials; the surface finish of the hard chrome-plated mirror roller is high, and it is equipped with a circulating water chilling down system. Temperature control accuracy +/- 1 ℃.

$ 24279.00

The stainless steel funnel is used to ensure that the surface is smooth and free of static electricity. It is equipped with two specifications of funnel, which are suitable for free-flowing powder and caking trend powder respectively. The receiver volume is 500ml, and the sampling volume is 510-550ml, which meets the standard test requirements.

$ 875.00

Using Kempf measurement method, the probe pressure range is 50-250N, the accuracy is +/- 10%, and it is equipped with φ 40mm rubber probe, which can accurately evaluate the degree of coating chalking.

$ 393.00

Constant pressure ensures uniform sampling, suitable for a variety of powder material testing, implementation of GB9087-88 and other standards, improve sampling accuracy and conformity.

$ 222.00

Articles

High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Hall flowmeter measures the flowability of spray powder
This article introduces how a Hall flowmeter measures the flowability of spray powder. It uses a standard funnel to measure the time required for a certain mass of powder to flow out under gravity—the shorter the time, the better the flowability.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Sand Falling Test Apparatus for Measuring the Wear Resistance of Powder Coatings
The sand falling test instrument determines the wear resistance of powder coatings by simulating sand particle impact. During the test, abrasive material falls vertically from a specified height, continuously scouring the coating until the substrate is exposed. The wear resistance is evaluated based on the mass of abrasive material consumed.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.
Pendulum hardness tester measures the damping hardness of powder coatings.
This article introduces the method of testing the damping hardness of powder coatings using a pendulum hardness tester. The test is based on the principle of energy attenuation, where the hardness is reflected by the time it takes for the amplitude of the pendulum to decay as it swings on the coating surface, with a longer time indicating a harder coating.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.