Fully Automatic Thickness Meter

The fully automatic thickness gauge measures material thickness by emitting signals through non-contact sensors and receiving reflected waves. It is used in production lines for coatings, plastics, and other materials to monitor thickness in real time, ensuring product uniformity and reducing manual errors.

Instruments

Using positive pressure test principle, Measurement range 0~ 1.6MPa, fully automatic operation, support three test modes, built-in calibrating program, suitable for quantitative measurement of various sealing performance indicators.

$ 1332.00

The fully automatic electronically controlled hydraulic pump provides smooth and continuous pulling force with +/- 1% accuracy, built-in rechargeable battery supports 200 tests, and IP65 Protection Rating ensures durability.

$ 4212.00

Pneumatic fixture to achieve automatic clamping, no manual operation; Measurement range covers 10~ 16000mN, support a variety of sheet material Tear strength detection, equipped with 3.2 inch LCD display and thermal printer.

$ 2308.00

Fully enclosed metal Furnace body to enhance Baseline Stability, with imported alloy Sensor to enhance corrosion resistance; Temperature range covering room temperature to 600 ℃, support 0.1~ 100 ℃/min program temperature control, with 0.001 ℃ resolution and Automatic calibration function.

$ 3672.00

Featuring a Cotex-M4 ARM processor, it employs pneumatic sample clamping and an integrated weighing mechanism to achieve fully automated measurement. The oscillation frequency is adjustable from 50 to 200 times per minute, with a weighing resolution of up to 0.001g.

$ 3059.00

Using 7-inch true color Touchscreen and 32-bit microprocessor, Temperature range RT +~ 400 ℃, with automatic atmospheric pressure compensation and over-temperature protection function, the test process is fully automated.

$ 5399.00

Adopt a new generation of High Accuracy Sensor to ensure stable and reliable weighing, with a reaction time of less than 2 seconds, a fully automatic internal calibration function triggered by time and temperature, and support for a variety of weighing units.

$ 935.00

Using three-axis automatic precision control, the maximum cutting section of 200 * 150mm, with intelligent cutting function can change the amount of feed according to the hardness of materials, fully enclosed structure to ensure safe operation, mobile magnetic filtrate circulating water Tank to improve the cutting mass.

$ 37930.00

Measurement accuracy of +/- (0.05 mils + 1%) with 90 ° right angle design for low headroom area measurement, fully waterproof structure for underwater operation, stainless steel sealing Probe for durability.

$ 895.00

Temperature range -40~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using imported Air-Cooled fully enclosed refrigeration Compressor, with grounding protection, over-temperature protection, refrigerator overpressure overload protection and other functions.

$ 5187.00

Using high-performance MCS-51 single chip microprocessor control, weighing range 0-110g, accuracy 1mg, with RS232C output interface and automatic correction function to ensure high weighing results Accuracy.

$ 412.00

High Accuracy Displacement Sensor, Measurement range 0~ 6mm, resolution 0.001mm, with automatic calculation of tightness function, built-in thermal printer, suitable for a variety of material thickness detection.

$ 1945.00

Adopt fully enclosed and environmentally friendly Compressor refrigeration system, Temperature Uniformity +/- 0.05 ℃, can directly start refrigeration at 200 ℃ high temperature, equipped with multiple Safety protection devices to ensure stable and reliable operation.

$ 3478.00

Adopt 32-bit ARM processor to improve data processing speed, equipped with 5-inch true color Touchscreen to simplify the operation process, support one-click whiteness and chroma testing, Repeatability color coordinates ≤ 0.0003.

$ 3026.00

Spreader accuracy of +/- 0.003mm, Spreader thickness 0~ 10mm adjustable, using integrated drawdown blade design and automatic feeding system, support Vacuum chuck and heating function, ensure Spreader uniform and efficient.

$ 13306.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.