Zinc Electrolysis Thickness Tester

The zinc electrolytic thickness gauge measures the thickness by electrolytically dissolving the zinc layer and calculating it based on the dissolution time and current. It is used to detect the thickness of zinc coatings on galvanized sheets, zinc alloys, and other surfaces, and is applied in metal corrosion protection and quality inspection.

Instruments

With 60V DC voltage and 25A current output to meet the needs of large area samples; equipped with electrolysis liquid circulation and chill down device to ensure polishing conformity and Stability.

$ 5286.00

Using magnetic Induction and eddy Current dual principle, it can simultaneously measure paints and zinc layer thickness. Measurement range is 0-1500 μm, accuracy is +/- 1%, suitable for composite coating system inspection.

$ 1387.00

Using pre-pressure technology to ensure stable exudation of electrolysis in viscous samples, equipped with Protelyte oily electrolysis solution to avoid protein reaction, membrane Impedance < 500MΩ, Temperature range 0~ 130 ℃, suitable for high temperature and high voltage environment.

$ 425.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

Pre-pressurization technology is used to ensure stable exudation of electrolysis solution in viscous samples, equipped with 3 ceramic core liquid network parts and Protelyte oily electrolysis solution, membrane Impedance < 200MΩ, effectively prevent protein settling blockage, suitable for high temperature and high voltage environment.

$ 243.00

Pre-pressurization technology is used to prevent clogging of viscous samples, Protelyte oily electrolysis solution avoids protein reaction, ceramic core liquid network design, Temperature range -5~ 100 ℃, Membrane Impedance < 150MΩ.

$ 469.00

Pre-pressurization technology is used to prevent clogging of viscous samples, Protelyte oily electrolysis solution avoids protein reaction, three ceramic core liquid network design, Temperature range 0~ 130 ℃, Membrane Impedance < 200MΩ.

$ 469.00

Using imported cold light source and narrow-band interference technology, the detection limit is 0.05mg/L, supports continuous measurement and standard Measurement mode, and the built-in large-capacity lithium battery can store 4000 sets of data.

$ 816.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Imported long-life Illuminant and narrowband filter system, Optical inspection stability is less than 0.002A/20min, measurement range 0.2~ 5.00mg/L, support long-term data storage and user self-calibration Linear dispersion.

$ 499.00

Using eddy Current thickness measurement principle, Measurement range 0-1000μm, resolution 0.1μm, minimum measurable convex curvature 3mm, with automatic shutdown and low voltage prompt function.

$ 267.00

Operating temperature range 0-70 ° C, temperature sensor, multi-pin connector support, maximum pressure 0.2 bar.

$ 215.00

Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.

$ 296.00

Pre-pressurization technology is used to ensure stable exudation of electrolysis in viscous samples, equipped with a three-ceramic core liquid network structure to reduce the risk of clogging, Protelyte oily electrolysis solution avoids reaction with proteins, membrane Impedance is less than 200MΩ, suitable for -5~ 100 ℃ Temperature range.

$ 275.00

Measurement range 200-600ppm, accuracy +/- 6% reading, LED Illuminant 610nm, automatic shutdown function, suitable for seawater calcium Ion concentration detection.

$ 215.00

Articles

Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Copper nanowire and zinc oxide thin film preparation coater
The coating machine is a key device for preparing copper nanowires and zinc oxide thin films, which uniformly coats slurry onto a substrate through methods such as blade coating to form a thin film.
Selection of Coating Thickness Measurement Methods: Coulometry vs. Dissolution in Electrolytic Thickness Gauges.
This article compares two techniques in electrolytic thickness gauges: the coulometric method and the dissolution method. The coulometric method measures coating thickness through electrochemical dissolution, making it suitable for single-layer metal coatings with simple operation and high accuracy. The dissolution method, on the other hand, measures thickness via chemical dissolution, making it more appropriate for multilayer or complex coatings.