Flame Retardant Tester

The flame retardancy tester simulates flame contact with materials to detect their burning time, spread rate, and self-extinguishing properties. It is used to evaluate the flame retardant characteristics of materials such as plastics and textiles, ensuring that products comply with safety standards.

Instruments

The equipment adopts stainless steel structure to resist corrosion, equipped with automatic ignition and Timing function, combustion time 0~ 99.99 seconds, gas lamp Nozzle inner diaMeter 9.5mm, to ensure accurate and reliable testing.

$ 670.00

1KW standard blowtorch, flame height 170-190mm, support 0.1-999 seconds holding time setting, with automatic timing and high voltage ignition function, suitable for flame retardant performance testing of various cable materials.

$ 1219.00

Using dual-channel proportional value display, knob type operation is easy, flame size can be pre-selected, equipped with flameout protection device. Detection limit K ≤ 0.004mmol/L, Na ≤ 0.008mmol/L, Response Time < 8S, high stability.

$ 820.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Five elements can be combined with any combination at the same time, automatic ignition and flame monitoring, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.

$ 2655.00

Using PLC Control system and Touchscreen operation, equipped with K-type Thermocouple and intelligent PID temperature control Meter, Heating time 54s +/- 2s from 100 ℃ to 700 ℃, Interior volume ≥ 4.0m ³, to ensure accurate and efficient testing.

$ 6205.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, the passband is narrow, and the Sensitivity is high; the five elements can be combined with any combination of direct reading measurement at the same time, the Response Time is less than 8 seconds, and the relative change of Stability in 15 seconds does not exceed 2%.

$ 2655.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, flexible and convenient; Internal standard channel can correct the signal to ensure stable and reliable performance.

$ 2171.00

Dual-channel proportional value shows that the sample suction and spray volume is less than 6mL/min, the Response Time is less than 8 seconds, and it has a flameout protection device, which is easy, stable and reliable to operate.

$ 946.00

Dual channel LED digital display, Measurement accuracy, sodium detection limit ≤ 0.008mmol/L, support lithium calcium detection, using silicon Photocells, photovoltaic cells and liquefied petroleum gas fuel, sample volume is small and Sensitivity is high.

$ 1493.00

Using dual Sensor temperature measurement system, the maximum operating temperature is 380 ℃, Temperature range environment temperature to 380 ℃, support continuous work, large heating area and no open flame design.

$ 140.00

Dual channel LED digital display ensures clear reading, using silicon Photocell, photovoltaic cell detection to make the measurement results accurate and stable, Response Time is less than 8 seconds and has flameout protection function, safe and reliable operation.

$ 1332.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Support any combination of five elements direct reading measurement, Response Time is less than 8 seconds, Stability relative change within 15 seconds ≤ 2%.

$ 3543.00

Using concave Holographic grating design, Light spectrum pure and accurate, narrow passband, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, Response Time is less than 8 seconds, Stability relative change within 15 seconds does not exceed 2%.

$ 3543.00

Using concave Holographic grating design, Light spectrum is pure, narrow passband, Sensitivity is high, linearity is better; Support any combination of five elements while direct reading measurement, automatic ignition and flameout protection function to ensure safety.

$ 3543.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, narrow passband, high Sensitivity, good linearity; supports any combination of five elements for direct reading measurement, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.

$ 4430.00

Articles

How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.