Using circulating water as the working fluid, the maximum Vacuum Level is -0.098Mpa, the pumping rate is 80L/min, the special fluid muffler reduces the noise, the double tap design can be used alone or in combination, and the ABS engineering plastic shell is resistant to corrosion.
Circular rotation synergistic vortex flow, completely discharged bubbles; American technology ST vacuum pump noise low Vacuum Level high; 8 groups of 5-stage formula can be memorized; Touchscreen easy to operate; Safety protection complete.
Using circulating water as the working fluid, the jet generates negative pressure, the pumping rate is 80L/min, the maximum Vacuum Level is -0.098Mpa, the double tap design can be used alone or in combination, and the special fluid muffler reduces the noise.
Vertical oscillation mode with 280rpm frequency, smooth operation and low noise, stainless steel spring universal fixture, can be adapted to a variety of test bottles, to meet a variety of mixing needs.
The equipment Oscillation Frequency 0~ 260rpm stepless adjustable, pendulum amplitude 20mm, smooth operation and low noise, the use of stainless steel spring universal fixture, can be adapted to a variety of bottles, to meet a variety of mixing needs.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with six safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, temperature control accuracy +/- 0.5 ℃, with low water level protection, temperature runaway alarm and other multiple safety functions to ensure the stable operation of the experiment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure the stability and reliability of the experimental process.
Oscillation Frequency 0~ 260rpm, pendulum amplitude 20mm, smooth operation and low noise, support swirling, up and down, left and right oscillation mode, to meet the needs of different samples mixing.
Oscillation Frequency 0-300rpm adjustable, pendulum amplitude 20mm horizontal reciprocating, equipped with 0-120 minutes timing function, motor power 40W, low noise and smooth operation.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
The equipment supports reciprocating oscillation, the frequency reaches 320rpm, the swing amplitude is 20mm, the operation is stable and the noise is small, and it can be adapted to a variety of test bottles for mixing operation.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure stable and reliable operation.
Two-stage pump structure is equipped with PTFE material pump head, strong corrosion resistance, maximum Flow rate 125L/min, Ultimate vacuum degree 15-20mbar, no pollution and maintenance, low noise and low temperature rise.
With circulating pump monitoring and peristaltic pump dosing system, pH Measurement accuracy +/- 0.05pH, ORP accuracy +/- 5mV, support automatic temperature compensation and data recording functions.