Automatic Drawing Inspection Instrument

The pull-off adhesion tester measures the adhesion value between the coating and the substrate by clamping the sample and applying a vertical pulling force. It is used to evaluate the bonding strength of coatings and inks on surfaces such as metal and plastic, commonly employed in quality inspection and research and development processes.
Selection
When selecting, consider the type of material being tested and the range of coating thickness to match the instrument's measurement range and fixture specifications. Ensure the equipment complies with standards such as ASTM D4541 and ISO 4624, check the sensor accuracy and software data export capabilities, and refer to the stability of actual sample testing.

Terms

Standards

Instruments

The device uses mechatronics design, weight only 3.5kg easy to carry; equipped with High Accuracy S type Sensor, accuracy of 0.5% F.S; support 0.1-50 mm/min adjustable drawing speed, built-in lithium battery for outdoor use.

$ 1824.00

Electric Circle-drawing is used to ensure uniform speed and constant strength, Travel 20-80mm adjustable, Rotation speed 10-120 +/- 1 rpm adjustable, equipped with automatic judgment prompts and precision dual rail system to improve test Repeatability and data accuracy.

$ 1397.00

Contains 12 types of tie Rods and adapters from M6 to M30, suitable for a wide range of bolt sizes, providing comprehensive inspection coverage.

$ 211.00

Hollow self-resetting hydraulic cylinder structure, maximum pulling force 500kN, Indication Error ≤ +/- 1% F. S; with 240 * 320 color Touchscreen, support automatic data storage and drawing force-time Linear dispersion display function.

$ 1192.00

Maximum pulling force 50kN, hollow self-reset structure, digital pressure Gauge with automatic calculation, backlight, peak holding function, manual pump maximum Operating Pressure 63MPa, compact and portable structure.

$ 475.00

Adopt photoelectric detection and microcomputer servo system, High Sensitivity, Measurement range +/- 45 °, Minimum reading +/- 0.001 °, Repeatability ≤ 0.002 °, LED display and membrane switch operation for easy reading, Cast aluminum base to ensure Stability.

$ 1372.00

Adopting manual sprocket drive structure, Working Travel ≥ 80mm, equipped with four weight combinations, accurate drawing is achieved through replaceable 808 stylus, and different diaMeter graphics are supported.

$ 325.00

2 samples can be measured at the same time, using platinum temperature sensor and digital Optical inspection sensor, temperature control accuracy 0.1 ℃, heating rate 0.1-10 ℃/min, automatic recording of the experimental process.

$ 2913.00

The steel stylus is used for precision drawing, the diaMeter range is 0-10.5 mm, and it is equipped with multiple sets of weights to achieve accurate loading.

$ 332.00

Hollow self-resetting hydraulic cylinder design, center aperture 18mm, with peak holding and automatic shutdown functions, manual pump pressurization, suitable for laboratory and field use.

$ 690.00

Adopt cold Illuminant narrow-band interference Optical inspection system, Optical inspection stability is less than 0.002A/20min, support room temperature to 180 ℃ stepless temperature control, anti-chlorine interference up to 2000mg/L, batch processing of 20 water samples, easy to operate without changing pipes.

$ 1564.00

The CMOS integrated circuit is used to ensure stable counting, and the 7W energy-saving ring lamp side-shot illumination makes the colony contrast clear. The counter capacity is 0-999 to meet the needs of conventional detection. The probe pen marking function is avoided, and the repeability count is performed.

$ 151.00

Hollow self-resetting hydraulic cylinder design, maximum pulling force 30kN, center aperture 18mm, with peak holding and automatic shutdown function, simple operation suitable for on-site use.

$ 779.00

The pressure-sensitive element is used for automatic counting, the diaMeter of the culture dish supports ≤ Φ 90 mm, and it is equipped with dark deep background and annular fluorescent side-shot lighting. The colony contrast is clear, and the counting is fast and reliable.

$ 228.00

The four-pin design is equipped with four sizes of scribing needles, which can automatically draw a circular track with a diaMeter of 100mm, support three cycle modes of 6/12/24 hours, and the measurement error is controlled within +/- 0.5%.

$ 219.00

Articles

Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Application of Automatic Film Coating Machine in Waterproof Coating Finishing of Textiles
Automatic film coating machines are used for waterproof coating finishing on textiles, enabling precise control of coating thickness, improving uniformity and production efficiency.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium Battery Separators
This article introduces the application of automatic coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional
Application of Automatic Film Coating Machines in the Preparation of Uniform Coatings in Laboratories
This article introduces the application of automatic film applicators in preparing uniform coatings in laboratories. Traditional manual coating methods are influenced by the operator's experience, making it difficult to ensure coating consistency.
Pull-off Adhesion Tester for Quantitative Measurement of Varnish Adhesion.
The pull-off adhesion tester quantitatively measures the adhesion strength between a varnish coating and the substrate by vertically pulling off a test column. It is essential to ensure proper substrate preparation, complete curing of the coating, and the use of a suitable adhesive during testing.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Key operational points for determining the acid value of oils and fats using potentiometric titration.
This article introduces the key operational points for determining the acid value of oils and fats using potentiometric titration. The method principle involves dissolving the oil or fat sample, titrating it with a standard alkaline solution, automatically determining the endpoint based on the potential jump, and then calculating the acid value using the formula.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Key Points for Wet Film Thickness Control in the Preparation of Fluorocarbon Coatings for Photovoltaic Backsheets Using Automatic Film Coating Machines
This article introduces the key points of controlling wet film thickness in the preparation of fluorocarbon coatings for photovoltaic backsheets using an automatic coating machine. Wet film thickness directly affects the performance and uniformity of the coating after curing, making its control crucial.
Alignment Accuracy Control Method for Four-Sided Preparator When Used with Automatic Coating Machine
This article explores the alignment accuracy control when using a four-sided preparator in conjunction with an automatic coating machine. Alignment accuracy directly affects the uniformity of the coating and the reliability of detection.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Programmable Automatic Film Coating Machine: Application Techniques of Multi-Speed Function in Gradient Coating Preparation
This article introduces how the multi-segment variable speed function of a programmable automatic film applicator can be used to prepare gradient coatings.