Air Constant Temperature Oscillator

The air constant temperature oscillator heats the air through an electric heating wire, uses a fan to circulate and maintain uniform temperature inside the chamber, and drives the tray to oscillate reciprocally via a motor. It is used for constant temperature mixing, dissolution, or reaction of samples, commonly applied in microbial culture, chemical synthesis, and sample pretreatment.
Selection
When selecting, consider that the temperature range and fluctuation should match the sample requirements, the oscillation frequency and amplitude should suit the container type, the tray size and load capacity should align with the experimental scale, the material's corrosion resistance should correspond to the usage environment, and the timing function and safety features should meet operational standards.

Terms

Instruments

The use of air circulation heating makes the temperature distribution uniform, the temperature fluctuation is less than 0.5 ℃, the internal non-uniformity is about 1.0 ℃, equipped with brushed stainless steel liner for easy cleaning, and supports thermostatic timing function.

$ 1816.00

The transparent vacuum chamber is sturdy and durable, and the automatic constant pressure air supply ensures the stability of the preset Vacuum Level. The range of Vacuum Level is 0~ -90KPa, and the test process is automatically completed with one-click operation, without the need for an external vacuum pump.

$ 877.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.

$ 740.00

The use of air circulation heating makes the temperature distribution uniform, the temperature fluctuation range is less than 0.5 ° C, the internal non-uniformity is about 1.0 ° C. It has PID adjustment and thermostatic timing functions, and the temperature control is accurate and stable.

$ 2333.00

Adopting PID adjustment technology implementation temperature fluctuation is less than 0.5 ℃, internal non-uniformity is about 1.0 ℃, equipped with air circulation system to ensure uniform temperature distribution, and with exhaust holes for gas discharge.

$ 4576.00

Using dry constant temperature Bath heating source, heat transfer uniform and fast, temperature control accuracy ≤ +/- 0.3 ℃. 12-hole independent blow pipe design to avoid cross-contamination, with its own air source, Flow rate 0-36L/min, compact and portable.

$ 251.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, temperature control accuracy of +/- 1.0 ℃, turbine centrifugal fan blade with the drum design, fan speed adjustable, studio mirror stainless steel easy to clean.

$ 1248.00

Elliptical trajectory vertical vibration design, vibration Frequency 660 times/min, maximum load 30KG, equipped with automatic cooling down system to maintain sample temperature stability, closed structure to reduce noise and pollution risk.

$ 14806.00

Temperature uniformity is ensured by centrifugal turbine forced air supply, temperature distribution accuracy +/- 1 ℃, Humidity Control Range 45% -90% RH, support 30-stage program control and power failure protection function.

$ 2203.00

Using dry constant temperature Bath heating source, uniform and fast heat transfer, 12-hole independent blow pipe to avoid cross-contamination, temperature control accuracy +/- 0.3 ℃, with small air source, suitable for rapid condensing in any environment.

$ 251.00

Mirror stainless steel liner and high-efficiency air circulation system, Temperature range -5~ 80 ℃, Humidity deviation +/- 3% R.H., support 99 cycle programs to ensure experimental Stability and uniformity.

$ 3402.00

Vertical double air duct air sleeve structure with turbine centrifugal forced air supply, Temperature Uniformity +/- 1.0 ℃, Fluctuation +/- 0.5 ℃, support speed regulating fan to adapt to lightweight samples, low water level alarm and forced heat dissipation to ensure safe operation.

$ 1248.00

Equipment Vibration Frequency 660 times/min, maximum load 30KG, elliptical trajectory movement to ensure that the sample test conditions independent equality, equipped with automatic chill down system to maintain temperature stability.

$ 18195.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Large diaMeter centrifugal wind wheel and optimized air supply circulation duct, heat flow evenly, Temperature Fluctuation +/- 2%, Temperature range RT + 5~ 250 ℃, can work continuously for a long time, high stoving efficiency.

$ 762.00