Tape Viscosity Tester

The tape viscosity tester evaluates adhesive performance by measuring the force required to peel the tape from a standard surface. The instrument evenly adheres the tape to the test plate, peels it at a constant speed, and records the peeling force curve via a sensor. It is used for quality inspection of tape stickiness, controlling coating processes, and comparing the performance of different tapes.
Selection
When selecting, consider the peel speed and angle required by the test standards. Match the sensor range according to the tape viscosity range. A temperature and humidity control function is needed to adapt to the test environment. The test board material should match the actual application surface. The instrument requires regular calibration to ensure data accuracy.
Tilt angle

Terms

Standards

Instruments

Equipped with 10-station synchronous test capability, 1000g weight and 1-999999 minute Timer, using SUS #304 steel plate to ensure test accuracy, and automatically recording tape peeling time.

$ 748.00

The adhesive force of the tape is 4.3N/cm, and the principle of cross-cut method is adopted, which is suitable for adhesion testing. The performance is stable and non-degumming, and the test results are accurate and reliable.

$ 166.00

11/16 inch standard width paper tape, capable of completing approximately 1800 cycles of testing per roll, must be stored at 23 +/- 2 ° C and 50 +/- 10% Humidity to ensure Stability.

$ 377.00

Adopt replica tape method to measure surface roughness, Peak Measurement range 20~ 115μm, accuracy +/- 5μm, with automatic subtracting substrate function, High Protection Rating, anti-solvent and water dust.

$ 935.00

Measured value 500N, suitable for tape, PCB, adhesive tape and other materials disbonding force test, supporting the Force Gauge test bench.

$ 89.00

Using 2000g +/- 5g roller load and 300mm/min rolling speed to ensure that the adhesive tape sample is flat and evenly adhered to the standard substrate, in line with CNS-11888 and PSTC-8 design standards.

$ 524.00

The equipment tests the initial Tack by short contact between steel ball and adhesive tape sample at a small pressure, adjustable tilt angle 0~ 60 °, rolling ball range 1/32 inch to 1 inch, suitable for a variety of material adhesion evaluation.

$ 240.00

Tack is good and non-degumming, adhesion reaches 7.6 N/cm, mass performance is stable, suitable for cross-cut adhesion testing, to ensure accurate film integrity assessment.

$ 174.00

Equipped with 1000g weight and 1~ 999999 minute Timer, using SUS #304 steel plate to ensure test accuracy and meet a number of national standards.

$ 414.00

With a 5/10 station design and room temperature range, multiple samples can be tested simultaneously, and the adhesion and durability performance can be accurately evaluated through the suspension weight measurement of the displacement or complete disengagement time.

$ 427.00

The width is 11/16inch, and each roll can be tested for about 1800 turns. It needs to be stored at a temperature of 23 +/- 2 ° C and a Humidity of 50 +/- 10% environment to ensure test Stability and Repeatability.

$ 81.00

Support 10 groups of samples synchronized testing and independent timing, temperature control range from room temperature to 70 ℃, hot air circulation to ensure Temperature uniformity, meet a variety of standard testing requirements.

$ 1380.00

10 station design can carry out multiple sets of tests at the same time. Temperature range RT +~ 250 ℃, hot air circulation to ensure uniform temperature. With over-temperature and electric overload automatic power-off protection, improve operation safety.

$ 1390.00

With 5 groups of independent testing capabilities, the temperature control range is from room temperature to 70 ° C, and the hot air circulation method is used to ensure Temperature uniformity.

$ 1284.00

500Ml capacity S6 viscosity standard oil, 20 ℃ viscosity 8.911mPa · s, 25 ℃ viscosity 7.498mPa · s, traceable to national standards, compatible with a variety of test equipment calibrating requirements.

$ 472.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.