Copper foil dyne pen

The dyne pen for copper foil applies a specific tension liquid through its tip and observes whether the liquid contracts or spreads on the copper foil surface to determine the surface energy. It is used to evaluate the surface treatment effectiveness and coating adhesion of copper foil, as well as to detect cleanliness and wettability during the production of copper-clad laminates and pretreatment for printed circuit boards.
Selection
When selecting, consider the common surface tension range of copper foil to match the measurement range of the dyne pen; choose fast-drying or slow-drying test fluid based on the humidity of the testing environment; the pen tip material should be wear-resistant and ensure uniform fluid discharge; verify the manufacturer's calibration certificate to ensure accuracy; a portable design is suitable for quick random inspections in the workshop.

Terms

Instruments

The stamping sampling method is accurate and fast, the limit cutting thickness range is 0.0045~ 0.1mm, and the sampling error is only +/- 0.01mm. The special treatment die blade is used, and it can be used for 2 years without replacement. It is suitable for high-fiber paper, metal foil and other materials.

$ 1848.00

Fiber wear-resistant pen tip design to ensure smooth and durable ink, accuracy of +/- 0.5 dyne, can quickly detect a variety of materials Surface Energy, sealing pen cap extended shelf life.

$ 99.00

Fiber wear-resistant pen design, Test accuracy of +/- 0.5 dyne, 15ML large capacity can be tested multiple times, 2-4 seconds to quickly obtain results, suitable for a variety of materials Surface Energy testing.

$ 99.00

Can accurately test whether the surface tension of the material is up to standard, support a variety of Color and pen customization, suitable for Plastic film, metal foil and other substrate detection.

$ 87.00

Using fiber wear-resistant pen design, width 5mm, Test accuracy +/- 0.5 dyne, ink smooth and detection only 4 seconds, suitable for a variety of materials surface tension test.

$ 99.00

The fiber wear-resistant pen tip is not easy to deform, and the writing is smooth; it can be accurate to +/- 0.5 dyne, and the test is accurate; 15ML large capacity, long shelf life; 38 dyne models are complete to meet various needs.

$ 99.00

Using fiber wear-resistant pen design, the accuracy can reach +/- 0.5 dyne, the results can be displayed 2-4 seconds after the test, equipped with 15ml large-capacity ink, support 28-70 kinds of tension value test requirements.

$ 99.00

The test results are fast without waiting, the full sealing pen cover has a long environmental protection life, is small in size and easy to carry, can accurately test the surface force Dyne Level, and the writing width is 7mm and the capacity is 7ml.

$ 89.00

Test results are fast, a wipe is available; full sealing pen design, long life and environmental protection; compact and portable, easy to disassemble and install; accurate test, can accurately determine the surface tension Dyne Level.

$ 89.00

The test results are fast without waiting, the full sealing pen cover has a long environmental protection life, is small in size and easy to carry, can accurately test the surface tension Dyne Level, and the writing width is 7mm and the capacity is 7ml.

$ 89.00

Adopt fiber wear-resistant pen head design, ink smooth and not easy to deform, Test accuracy of +/- 0.5, provide 38 dyne models to choose from, sealing pen cap to prevent volatilization, long service life and easy operation.

$ 99.00

Using fiber wear-resistant pen tip, ink smooth and not easy to deform, Test accuracy of +/- 0.5 dyne, 2-4 seconds after drawing the line to observe the results, suitable for a variety of substrates Surface Energy detection.

$ 99.00

The use of fiber wear-resistant pen to ensure smooth testing, Accuracy of +/- 0.5 dyne, 2-4 seconds after line film formation quickly display results, bright colors easy to observe details.

$ 99.00

No need to wait for a wipe to get the result, full sealing pen cover to ensure environmental protection and long life, 7ml capacity design portable and practical, can accurately test the surface tension Dyne Level, suitable for a variety of material detection.

$ 89.00

The fiber wear-resistant pen tip is used to ensure smooth ink output, the 15ml large-capacity design supports long-term use, and the Accuracy is up to +/- 0.5 dyne. A total of 38 models from 28 to 70 are provided to meet various testing needs, and the operation is simple and fast.

$ 99.00

Articles

Dyne Pen Selection, Surface Energy Test Range, and Pen Tip Lifespan
The dyne pen is used to evaluate the wettability of material surfaces, reflecting the effectiveness of treatments by measuring surface energy.
The film coater achieves controllable coating of lithium-ion battery anode slurry on copper foil.
This article explores how coating machines control the application process of the negative electrode slurry onto copper foil in the manufacturing of lithium-ion batteries.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
The coating machine in the laboratory ensures a more stable functional layer on the surface of copper and aluminum foils.
The laboratory coating machine is used to apply functional layers on the surfaces of copper foil and aluminum foil. By precisely controlling parameters such as coating speed, slurry viscosity, and drying temperature, it enhances the uniformity and adhesion of the coatings.
Application of Tensile Testing Machine in Coating Peel Strength Testing of Silicon-Carbon Anode Materials
This article introduces how to use a tensile testing machine to measure the bonding strength between silicon-carbon anode material coatings and copper foil substrates in lithium-ion battery research and development. During the test, the coating is peeled off using the 180-degree peel method at a constant speed, and the force variations throughout the peeling process are recorded.