Powder Moisture Tester

The powder moisture analyzer works by heating the sample to evaporate moisture and calculating the water content through weight loss. It is used to detect the moisture content of materials such as powders and granules and is applied in production and quality control across industries including chemical, food, and pharmaceutical sectors.
Selection
When selecting a powder moisture analyzer, factors such as sample characteristics, measurement range, accuracy requirements, heating method, and ease of operation should be considered. Choose the appropriate model based on the actual application scenario, and pay attention to the instrument's stability and maintenance costs.

Terms

Standards

Instruments

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Can test flowability, Angle of Peace and Loose Bulk Density, equipped with 30ml stainless steel measuringflask and double powder plate, funnel diaMeter can be selected 5mm or 2.5mm, for precise control of powder mass.

$ 993.00

Double pulse Back flushing automatic powder cleaning, Laminating filter accuracy of 0.3 microns, powder gas separation efficiency, stainless steel material is durable, color change operation is simple, improve dust recovery efficiency.

$ 1655.00

Using fixed funnel method to measure powder flowability, equipped with 10mm inner through Glass funnel and 0-100mm scale struts, can accurately measure cone height, meet the requirements of Pharmacopoeia and ISO standards.

$ 535.00

Standard funnel method for metal powder flowability measurement, equipped with 2.5mm and 5mm pore diaMeter stainless steel funnel, can accurately measure 50g powder flow time to +/- 0.01s, suitable for powder testing such as cemented carbide.

$ 525.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

The stainless steel funnel is used to ensure that the surface is smooth and free of static electricity. It is equipped with two specifications of funnel, which are suitable for free-flowing powder and caking trend powder respectively. The receiver volume is 500ml, and the sampling volume is 510-550ml, which meets the standard test requirements.

$ 875.00

Four 25 ° inclined quartz Glass baffles are used to guide the powder flow and are equipped with a 25 +/- 0.05ml standard cylindrical Cup to achieve a loose powder state through natural gravity, ensuring the accuracy and Repeatability of density testing.

$ 687.00

The injection limited bottom surface method is used to directly measure the angle of repose, the funnel taper is 60 ° +/- 0.5 °, and the outflow diaMeter is 5mm, which is suitable for powder flowability analysis of different particle sizes and shapes.

$ 545.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.

$ 359.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Moisture Analyzer Combined with Karl Fischer Method for Measuring Moisture Content in Resin Solvents.
This article introduces the use of the Karl Fischer method in conjunction with a moisture analyzer to measure the water content in resin solvents.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
Application of Coulometric Moisture Titrator in Moisture Detection of Electronic Components
Coulometric moisture titrators operate based on the principle of electrolysis, directly calculating the moisture content in samples by measuring the electrolytic charge without the need for calibration. In the field of electronic components, moisture can lead to issues such as corrosion and reduced insulation, making its detection critically important.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.