Standard Sample Preparation Device

The standard sample preparer uniformly combines the sample with a carrier through mechanical mixing, coating, or calendaring to create reference specimens with standard thickness or concentration. It is used for laboratory instrument calibration and quality control, and in the coatings and inks industry, it can prepare test samples such as color panels and thin films.
Selection
When selecting, consider matching the sample viscosity with the applicator specifications. Metal scrapers offer good wear resistance, and the adjustment mechanism should have a fine-tuning function. Choose the working width based on the substrate size, while also paying attention to ease of cleaning and compatibility with accessories.

Terms

Instruments

The hydraulic pump provides 16Mpa pressure to ensure the sample is tight, and the water chilling down system is equipped to speed up the sample preparation. The unique swirl/spin lock design simplifies the operation, and the program control realizes the heating to 180 ° C and the adjustable holding time, and the performance is stable and reliable.

$ 4600.00

The stamping design can cut the 15mm width sample, the parallelism of the two sides of the sampling is less than or equal to 0.025mm, and the width error is +/- 0.1mm, which meets the accurate sampling requirements of various physical performance tests of paper and Cardboard.

$ 1153.00

The accessory offers 15 well positions, each with a capacity of 2.0ml, and is designed as standard to ensure compatibility, facilitating efficient sample separation and stable storage.

$ 127.00

Bar and drawdown blade double coating method, coating speed 1-300mm/s stepless speed regulation, meyer Rod coating accuracy +/- 0.001mm, clamshell drawdown blade design is easy to clean, Touchscreen control operation is simple.

$ 2494.00

Using meyer Rod coating accuracy of +/- 0.001mm and Blade Coating accuracy of +/- 0.003mm, clamshell Drawdown blade for easy cleaning, Spreader speed 1~ 300mm/s stepless speed, support a variety of substrate material coating.

$ 2817.00

Support 100 ° C high temperature treatment, compatible with 96-well 0.2ml standard board design, can be matched with a variety of centrifuge tube modules, to achieve flexible experimental configuration and efficient Sample Handling.

$ 148.00

Standard HX-D module, support 35 2.0ml centrifuge tubes, withstand 100 ℃ high temperature, adapt to a variety of modules to meet the needs of multi-sample thermostatic treatment.

$ 148.00

The extrusion process ensures accurate 16 micron wet film thickness, the stainless steel is durable and provides 300 mm application width for efficient sample preparation.

$ 160.00

Fixed cut 15mm wide sample, sampling width error +/- 0.1mm, parallelism on both sides ≤ 0.1mm, suitable for a variety of paper test items.

$ 315.00

Using automatic mechanical pressurization and heating technology, the inlay process is completed automatically, the Heating power is 650W, and the mold sleeve specification is 25mm, which is suitable for edge protection of small irregular samples.

$ 3612.00

Adjustable application width, with automatic Spreader function, easy to operate, Repeatability is good, suitable for a variety of samples of laboratory prepative.

$ 4914.00

Double disc design supports independent operation of grinding and polishing, stepless speed range of 20~ 120rpm, pneumatic pressurization and magnetic quick disc change structure, equipped with automatic locking and water outlet functions, can simultaneously clamp 6 samples to achieve efficient automatic sample preparation.

$ 9400.00

The precision preparation process is adopted, and the capacity of 400ml meets the needs of routine experiments. It is suitable for instrument calibrating and quality control processes to ensure the accuracy and Repeatability of analytical data.

$ 151.00

Support 10~ 20mL small sample testing, range 12~ 6000000mPa · s, equipped with continuously variable speed and temperature control functions, repRoducibility up to +/- 0.5% F.S.

$ 1519.00

Only 5-18ml sample volume is required to complete the test, the sample cartridge is easy to clean and load, and the 316L material measuringflask can be customized for easy observation and detailed analysis of fluid characteristics.

$ 787.00

Articles

Wet film applicator for applying color paint to a specified wet film thickness.
A wet film applicator is a laboratory tool used to apply a predetermined thickness of wet paint film onto a flat substrate, providing the foundation for subsequent dry film performance testing.
Alignment Accuracy Control Method for Four-Sided Preparator When Used with Automatic Coating Machine
This article explores the alignment accuracy control when using a four-sided preparator in conjunction with an automatic coating machine. Alignment accuracy directly affects the uniformity of the coating and the reliability of detection.
Film applicator standardized preparation of test samples.
The film applicator is a crucial tool in fields such as coatings and inks for preparing test samples, ensuring uniform thickness and a smooth surface through standardized operations. The article introduces its scraping-based working principle and the selection between manual and automatic types.
Coating film preparation techniques: comparison between wire-wound applicators and wet film preparators
This article compares two commonly used tools in laboratory coating film preparation: the wire rod coater and the wet film applicator.
The importance of maintaining a constant speed when using a wet film applicator for coating.
When using a wet film applicator, maintaining a constant speed during the scraping process is crucial for coating uniformity. The scraping speed directly affects the wet film thickness, and fluctuations in speed can lead to defects such as streaks and uneven thickness, compromising the repeatability and accuracy of experimental results.
The difference between a wire bar coater and a gap-type wet film applicator.
The wire-wound drawdown bar directly quantifies the coating through the gap between wires, making it suitable for thin coating preparation with high precision, particularly for low-viscosity fluids. In contrast, the gap-type wet film applicator indirectly controls film thickness through the groove depth, with the actual coating thickness significantly influenced by material properties, making it more suitable for high-viscosity coatings and thick film preparation.