Powder Fineness Meter

The powder fineness meter measures particle size distribution through sieving or laser diffraction. It is used to control the uniformity of raw material particles in industries such as coatings and plastics, ensuring stable product coating thickness or molding quality.
Selection
When selecting, consider matching the measurement range to the sample particle size. Wet method instruments are suitable for materials prone to agglomeration, while dry method instruments are better for dry powders. Sieving-based instruments are more cost-effective, whereas laser-based ones offer higher precision. Balance industry standard requirements with daily testing efficiency.

Terms

Standards

Instruments

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

The kit can realize automatic grinding fineness Gauge operation, improve test Repeatability, suitable for standard scraper fineness Meter supporting use, simplify the experimental process.

$ 1623.00

Can test flowability, Angle of Peace and Loose Bulk Density, equipped with 30ml stainless steel measuringflask and double powder plate, funnel diaMeter can be selected 5mm or 2.5mm, for precise control of powder mass.

$ 993.00

Double pulse Back flushing automatic powder cleaning, Laminating filter accuracy of 0.3 microns, powder gas separation efficiency, stainless steel material is durable, color change operation is simple, improve dust recovery efficiency.

$ 1655.00

Using fixed funnel method to measure powder flowability, equipped with 10mm inner through Glass funnel and 0-100mm scale struts, can accurately measure cone height, meet the requirements of Pharmacopoeia and ISO standards.

$ 535.00

Standard funnel method for metal powder flowability measurement, equipped with 2.5mm and 5mm pore diaMeter stainless steel funnel, can accurately measure 50g powder flow time to +/- 0.01s, suitable for powder testing such as cemented carbide.

$ 525.00

The stainless steel funnel is used to ensure that the surface is smooth and free of static electricity. It is equipped with two specifications of funnel, which are suitable for free-flowing powder and caking trend powder respectively. The receiver volume is 500ml, and the sampling volume is 510-550ml, which meets the standard test requirements.

$ 875.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-25μm, ergonomic design, easy to hold, suitable for particle size and fineness of grinding detection.

$ 1157.00

Four 25 ° inclined quartz Glass baffles are used to guide the powder flow and are equipped with a 25 +/- 0.05ml standard cylindrical Cup to achieve a loose powder state through natural gravity, ensuring the accuracy and Repeatability of density testing.

$ 687.00

The injection limited bottom surface method is used to directly measure the angle of repose, the funnel taper is 60 ° +/- 0.5 °, and the outflow diaMeter is 5mm, which is suitable for powder flowability analysis of different particle sizes and shapes.

$ 545.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-250μm, ergonomic design for easy holding, suitable for particle size and fineness of grinding inspection.

$ 1531.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-15μm, ergonomic design, easy to hold, suitable for particle size and fineness of grinding detection.

$ 1157.00

Double groove design can achieve rapid fineness detection, Measurement range 0~ 100μm, accuracy +/- 2 microns, wear-resistant and anti-corrosion stainless steel material, suitable for a variety of material fineness determination.

$ 1086.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-100μm, suitable for particle size and fineness of grinding inspection, ergonomic design for easy grip.

$ 1157.00

Constant pressure ensures uniform sampling, suitable for a variety of powder material testing, implementation of GB9087-88 and other standards, improve sampling accuracy and conformity.

$ 222.00

Articles

Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
The Key Role of Apparent Density Meters in Assessing Powder Flowability.
This article discusses how a bulk density tester is used to evaluate the flowability of powders. Powder flowability is crucial in production. The instrument measures the bulk density and tapped density, then calculates the compressibility index and Hausner ratio. These two parameters directly reflect the quality of powder flow.
The combination of bulk density tester and angle of repose tester provides a one-stop solution for powder flowability testing.
This article introduces a method for comprehensively evaluating powder flowability in powder engineering by combining the use of an apparent density tester and an angle of repose tester. Apparent density reflects the packing characteristics of the powder, while the angle of repose indicates its ease of flow.
An article tells you how to choose a fineness gauge.
This article introduces how to select and use a grind gauge. It is a tool for measuring particle size in coatings and inks. When selecting one, the first step is to choose the appropriate range based on the estimated fineness of the sample (commonly 0-50 µm or 0-100 µm).