CO sensor

CO sensors operate based on electrochemical or semiconductor principles, detecting changes in carbon monoxide concentration and outputting signals. They are used for environmental safety monitoring, industrial process control, and combustion equipment detection to ensure personnel safety and production compliance.
Selection
When selecting a CO sensor, consider the detection range and accuracy requirements, clarify the ambient temperature and humidity conditions, confirm the output signal type and device compatibility, check explosion-proof certifications and service life, and evaluate the installation method and maintenance needs.

Terms

Standards

Instruments

Equipped with infrared CO2 sensor accuracy of 0.1%, CO2 recovery time ≤ concentration value × 1.2min, built-in ultraviolet sterilization lamp and microbial Filter, effectively prevent foster pollution, the use of antibacterial stainless steel lumen for easy cleaning and maintenance.

$ 1555.00

Using Infrared Sensor to monitor CO2 concentration, not affected by Temperature Humidity, CO2 concentration recovered within 5 minutes after opening the door, Temperature Fluctuation +/- 0.2 ℃, equipped with Microbial Filter and door temperature heating system to prevent condensation pollution.

$ 3338.00

Infrared CO2 Sensor Response Fast, Not Affected by Temperature Humidity, CO2 Recovery Time ≤ 3 minutes; Circulating wind speed automatically adjusts to avoid sample volatilization; Door temperature heating prevents condensate pollution.

$ 3402.00

Equipped with infrared CO2 sensor accuracy of 0.1%, with ultraviolet sterilization and door heating anti-condensation design, CO2 recovery time ≤ concentration value × 1.2 minutes, support RS-485 interface connection.

$ 4506.00

Equipped with infrared CO2 sensor accuracy of 0.1%, built-in ultraviolet sterilization lamp can effectively prevent pollution, support 0-20% CO2 concentration range, the use of antibacterial stainless steel cavity for easy cleaning and maintenance.

$ 3901.00

Using infrared CO2 Sensor control accuracy +/- 0.1%, gas sleeve heating heating, CO2 recovery time does not exceed the concentration value × 1.2 minutes, double door structure sealing good anti-pollution.

$ 1524.00

Infrared Sensor is used to monitor CO2 concentration, which is not affected by temperature and Humidity, and restores the set CO2 value within 5 minutes after opening the door; Equipped with Microbial Filter, the filtration efficiency of ≥ 0.3 μm particles reaches 99.99%, effectively preventing pollution.

$ 4177.00

Using Infrared CO2 Sensor, restore 5% concentration within 3 minutes after opening the door; Equipped with 90 ℃ heating and humidity sterilizing system, effectively eliminate microbial pollution; Temperature Fluctuation +/- 0.1 ℃, CO2 control accuracy +/- 0.1%.

$ 6505.00

The infrared CO2 sensor accuracy is +/- 0.1%, which is not affected by temperature Humidity; the circulating fan speed is automatically adjusted to avoid sample volatilization; the door temperature heating system prevents condensate pollution; the CO2 recovery time is ≤ 3 minutes, and the temperature recovery is ≤ 8 minutes.

$ 1835.00

The cavity preheating technology implementation +/- 0.8 ℃ Temperature Uniformity, equipped with infrared CO2 Sensor to ensure accurate concentration, standard ultraviolet sterilizing lamp to prevent cross-contamination, support remote monitoring function.

$ 4161.00

Using Infrared CO2 Sensor, Fast Response and No Temperature Humidity Affected, Control accuracy +/- 0.1%; Equipped with UV Sterilization and Microbial Filter to effectively prevent pollution; Automatic adjustment of circulating wind speed to avoid sample volatilization.

$ 3038.00

Infrared CO2 Sensor is not affected by Temperature Humidity, control accuracy +/- 0.1%; equipped with UV sterilization system and microbial Filter to effectively prevent pollution; automatic adjustment of circulating wind speed to avoid sample volatilization.

$ 2742.00

Infrared Sensor to achieve CO2 concentration ≤ 3 minutes rapid recovery, equipped with HEPA Filter to maintain 100 clean, support 90 ℃ high temperature heating and humidity sterilization, temperature fluctuation +/- 0.1 ℃ to ensure a stable foster environment.

$ 3590.00

Infrared CO2 Sensor control accuracy is stable, Temperature Fluctuation +/- 0.5 ℃, using double door structure and door temperature heating system, effectively prevent condensation and pollution, short recovery time.

$ 2295.00

Infrared CO2 Sensor to ensure accurate concentration control, Temperature Uniformity of +/- 0.3 ℃, with double door sealing and quick recovery function, effectively prevent condensation pollution, improve the Reliability of the experiment.

$ 1750.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Dart impact tester measures the toughness of packaging film.
The dart impact test evaluates the material's resistance to damage under dynamic impact, i.e., its toughness, by allowing a dart to fall freely and strike the packaging film. During the test, different impact energies are simulated by adjusting the weight of the dart or the drop height, and sensors are used to detect whether the film ruptures.
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
In the selection of illuminance meters, sensor type and measurement range are key considerations.
This article introduces the key points for selecting sensor types and measurement ranges when choosing an illuminometer.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Internal Bond Strength Scott Tester for evaluating interlayer bonding force of paper.
This article introduces the method of evaluating the interlayer bonding strength of paper using a Scott tester. The interlayer bonding strength affects the printing and mechanical properties of paper. During testing, the instrument peels the paper vertically through an adhesive test head, records the energy required for separation, and calculates the internal bond strength.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Key points for operating a hot melt adhesive softening point tester
The hot melt adhesive softening point tester is used to measure the softening temperature of materials when heated, which is important for quality control. Before operation, ensure that the ambient temperature is around 23 degrees, place the instrument level, check if the heating oil is clean, and calibrate the sensor.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
Comparison of Humidity Control Methods in Constant Temperature and Humidity Test Chambers: Wet and Dry Bulb Method vs. Electronic Sensor Method
This article will explain the principles, advantages, and disadvantages of these two methods to help you make a more informed decision when selecting equipment.