CO concentration monitor

The CO concentration monitor detects carbon monoxide gas levels using an electrochemical sensor, converting chemical signals into electrical signals for output. It is used for safety monitoring in industrial environments to prevent personnel poisoning and equipment failures, commonly found in places such as chemical plants, metallurgical facilities, and other locations where incomplete combustion occurs.
Selection
When selecting, confirm that the measurement range covers the on-site concentration range, and that the resolution and accuracy meet control requirements. Consider the sensor lifespan and calibration cycle, and ensure the protection rating is suitable for the installation environment. Check explosion-proof certification and output signal type to ensure compatibility with the existing system.

Terms

Standards

Instruments

Using Infrared Sensor to monitor CO2 concentration, not affected by Temperature Humidity, CO2 concentration recovered within 5 minutes after opening the door, Temperature Fluctuation +/- 0.2 ℃, equipped with Microbial Filter and door temperature heating system to prevent condensation pollution.

$ 3338.00

Infrared Sensor is used to monitor CO2 concentration, which is not affected by temperature and Humidity, and restores the set CO2 value within 5 minutes after opening the door; Equipped with Microbial Filter, the filtration efficiency of ≥ 0.3 μm particles reaches 99.99%, effectively preventing pollution.

$ 4177.00

Using microcomputer module control, CO2 control accuracy of 0.1%, temperature resolution of 0.1 ℃, equipped with CO2 and gas dual filtrate device, liner four corners arc design for easy cleaning.

$ 2400.00

Equipped with infrared CO2 sensor accuracy of 0.1%, with ultraviolet sterilization and door heating anti-condensation design, CO2 recovery time ≤ concentration value × 1.2 minutes, support RS-485 interface connection.

$ 4506.00

Using Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, equipped with high temperature heating and humidity sterilizing function, CO2 concentration is restored within 3 minutes after opening the door, and the circulating fan automatically adjusts the speed to avoid sample volatilization.

$ 5503.00

Equipped with infrared CO2 sensor accuracy of 0.1%, CO2 recovery time ≤ concentration value × 1.2min, built-in ultraviolet sterilization lamp and microbial Filter, effectively prevent foster pollution, the use of antibacterial stainless steel lumen for easy cleaning and maintenance.

$ 1555.00

Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, 3 minutes to quickly restore the set concentration; equipped with high temperature heating and humidity sterilizing function, effectively eliminate microbial contamination, circulating fan automatic speed control to protect the sample.

$ 4911.00

Imported Infrared Sensor, CO2 concentration control accuracy of +/- 0.1%, restore the set concentration within 3 minutes after opening the door; equipped with high temperature heating and humidity sterilizing system, can completely eliminate microbial pollution, circulating fan speed automatic adjustment to avoid sample volatilization.

$ 4122.00

Water-jacketed heating system is used to ensure uniform temperature stability, temperature control accuracy of +/- 0.3 ℃, CO2 concentration control accuracy of 0.1% and double filtrate device, effectively maintain the clean foster environment and prevent pollution.

$ 2468.00

Equipped with infrared CO2 sensor accuracy of 0.1%, CO2 uniformity +/- 0.1%, built-in UV sterilization lamp and microbial Filter, antibacterial stainless steel inner cavity four corners arc design for easy cleaning, support programmatic programming and Linear dispersion display function.

$ 4971.00

Using infrared CO2 Sensor control accuracy +/- 0.1%, gas sleeve heating heating, CO2 recovery time does not exceed the concentration value × 1.2 minutes, double door structure sealing good anti-pollution.

$ 1524.00

Equipped with infrared CO2 Sensor to achieve +/- 0.1% control accuracy, rapid recovery of concentration within 3 minutes; integrated 90 ℃ heating and humidity sterilizing system to eliminate microbial contamination, automatically adjust the circulating wind speed to avoid sample volatilization.

$ 4927.00

Equipped with infrared CO2 sensor accuracy of 0.1%, built-in ultraviolet sterilization lamp can effectively prevent pollution, support 0-20% CO2 concentration range, the use of antibacterial stainless steel cavity for easy cleaning and maintenance.

$ 3901.00

The cavity preheating technology implementation +/- 0.8 ℃ Temperature Uniformity, equipped with infrared CO2 Sensor to ensure accurate concentration, standard ultraviolet sterilizing lamp to prevent cross-contamination, support remote monitoring function.

$ 4161.00

Using Infrared CO2 Sensor, restore 5% concentration within 3 minutes after opening the door; Equipped with 90 ℃ heating and humidity sterilizing system, effectively eliminate microbial pollution; Temperature Fluctuation +/- 0.1 ℃, CO2 control accuracy +/- 0.1%.

$ 6505.00

Articles

How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Operating Specifications for the Determination of Hexavalent Chromium Content in Wastewater Using Colorimetric Titration Apparatus
This article introduces the standard operating procedure for determining hexavalent chromium content in wastewater using a colorimetric titrator. The method is based on the reaction between hexavalent chromium and diphenylcarbazide under acidic conditions to form a purplish-red complex, with the titration endpoint determined by monitoring changes in absorbance at a wavelength of 540 nanometers.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Internal Bond Strength Scott Tester for evaluating interlayer bonding force of paper.
This article introduces the method of evaluating the interlayer bonding strength of paper using a Scott tester. The interlayer bonding strength affects the printing and mechanical properties of paper. During testing, the instrument peels the paper vertically through an adhesive test head, records the energy required for separation, and calculates the internal bond strength.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.