Solar Illuminance Meter

A solar illuminance meter converts solar radiation into electrical signals through a photoelectric sensor and displays the illuminance value after calibration. It is used to measure outdoor light intensity and finds applications in paint weathering tests, agricultural light monitoring, and solar energy assessments.
Selection
When selecting, consider whether the measurement range and accuracy meet the requirements, check the compatibility between the sensor type and spectral response, confirm the protection rating for outdoor use, verify the validity of the calibration certificate, and compare the data stability of different brands.

Terms

Standards

Instruments

It can simultaneously test infrared, ultraviolet and visible light transmittance, and support the evaluation of total solar energy barrier rate. Using point array color screen visual display, the fuselage is lightweight and portable, with real-time dynamic Adjustment, Measurement accuracy is better than +/- 2%.

$ 170.00

Adopt high-power high-illumination LED Illuminant, Color temperature adjustment range 2300K-8500K, illuminance adjustment range 0-3000LX, no stroboscopic design life of more than 10,000 hours, uniform illumination surface can flexibly adjust the position angle.

$ 5366.00

The uniformity of the transmission surface exceeds 90%, the standard four-speed Color temperature is adjustable, the illuminance adjustment range is 0-120000Lux, and the thickness dimming knob is equipped to achieve precise control. Illuminant has no stroboscopic and the lifespan is more than 10,000 hours.

$ 5237.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illuminance adjustment range 0-3000LX, life of more than 10,000 hours, uniform irradiation without stroboscopic.

$ 7464.00

Measurement accuracy better than +/- 2% with high definition color screen progress bar, data locking and real-time dynamic Adjustment.

$ 149.00

Glass transmittance measurement is facilitated by split dual-machine design, integrated UV-IR-VIS 3-in-1 test function, equipped with laser alignment to ensure measurement accuracy +/- 2%, and supports built-in lithium battery power supply.

$ 357.00

Simultaneous measurement of infrared, ultraviolet blocking rate and visible light transmittance, resolution up to 0.1%, accuracy better than +/- 2%. Using high definition color screen progress bar visual display, with data locking and real-time dynamic Adjustment to ensure accurate measurement.

$ 122.00

Transmission surface uniformity of more than 93%, Color temperature adjustment range 2300K-8000K, Illuminance adjustable 0-160,000 Lux, Support Frequency adjustment 1-100KHz, life of more than 10,000 hours, can be connected through RS485 or WIFI computer control.

$ 5366.00

Split design with super magnetic automatic suction, can be directly tested on the installed film Glass, using 1400nm Infrared source and 365nm UV light source, measurement accuracy of +/- 2%, with laser alignment function to ensure measurement accuracy.

$ 390.00

150W Philips infrared lamp, peak wavelength 950nm, temperature measurement accuracy +/- 0.5 ° C, insulation accuracy +/- 2%, can quickly compare the insulation performance of different materials, the test time is only 1 minute.

$ 264.00

Measurable six paraMeters including UV barrier rate, visible light transmittance, infrared 950nm, 1400nm, Full IR and SHGC, using parallel light design, test accuracy +/- 2%, suitable for large Film thickness Glass, with real-time dynamic self-calibrating function.

$ 364.00

Color temperature adjustment range 2300K-8000K, illumination adjustment 0-1.3 million Lux, Frequency adjustment 1-100KHz, support RS485 to USB and WIFI connection, life up to 10,000 hours or more, to meet a variety of test conditions.

$ 4269.00

Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illumination up to 3000LX, life more than 10,000 hours, uniform irradiation surface and no stroboscopic, flexible adjustment of light box position and angle according to test requirements.

$ 12305.00

800L large capacity, Temperature range 4~ 50 ℃, Illumrination degree 0~ 30000LX six adjustable, can simulate day and night temperature Humidity changes, support 30 sets of program settings and independent temperature limit alarm.

$ 6194.00

Articles

How should one choose between the blade coating method and the spin coating method for perovskite film deposition experiments?
In the fabrication of perovskite solar cells, spin coating and blade coating are two commonly used film deposition methods, each with its applicable scenarios.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Xenon lamp aging test chamber for testing film weather resistance.
This article introduces how a xenon lamp weathering test chamber tests the weatherability of films. It uses a xenon lamp to simulate sunlight and controls conditions such as temperature and humidity to accelerate the aging process of the film, thereby evaluating its performance changes in outdoor environments.
In the selection of illuminance meters, sensor type and measurement range are key considerations.
This article introduces the key points for selecting sensor types and measurement ranges when choosing an illuminometer.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
Xenon lamp aging test chamber evaluates the long-term outdoor performance of resins.
Xenon lamp aging test chambers simulate environmental conditions such as sunlight, temperature, and humidity to accelerate the testing of the weather resistance of materials like resins in a laboratory setting.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
Rapid prediction of coating chalking and gloss loss failure through UV aging tests.
This article introduces how UV aging tests can quickly predict the failure of paint chalking and loss of gloss. The test accelerates coating aging in the laboratory by simulating solar ultraviolet light, temperature, and humidity, while observing phenomena such as chalking and loss of gloss.
Differences between xenon arc lamps, carbon arc lamps, and UV lamps in automotive interior and exterior light aging tests
Xenon lamps, carbon arc lamps, and UV lamps are three commonly used light sources in the photodegradation testing of automotive interiors and exteriors. Xenon lamps can simulate the full spectrum of sunlight, and by adjusting filters, they can match different environmental conditions, making them suitable for comprehensive evaluation of material aging.
Coating Process of Transparent Conductive Oxide Thin Films and Practice of Coating Machines
This article introduces the coating process and practice of coating machines for transparent conductive oxide films. Transparent conductive oxide films possess both transparency and conductivity, making them widely applicable in fields such as touch panels and solar cells.
Application of Coating Machines in the Fabrication of Functional Layers for Perovskite Solar Cells
This article introduces the application of coating machines in the preparation of functional layers for perovskite solar cells. The performance of perovskite cells depends on the uniformity and quality of thin films, such as the electron transport layer and the light-absorbing layer, which are primarily prepared through solution-based coating methods.
Xenon lamp aging test chamber for testing the weather resistance of exterior wall coatings.
Xenon lamp aging test chambers accelerate the aging of exterior wall coatings by simulating environmental conditions such as sunlight, temperature, humidity, and rainfall, to evaluate their weather resistance. The tests are conducted in accordance with standards such as ISO and ASTM, controlling key parameters such as irradiance, temperature, humidity, and spray cycles.