Built-in Probe design, surface temperature Measurement range -40~ 80 ℃, air temperature accuracy +/- 0.5 ℃, Humidity range 0~ 100% RH, providing stable and reliable dew point monitoring.
Built-in Air Temperature Humidity Sensor and K-Connector, with armored cable and magnetic surface temperature sensor to prevent accidental detachment, supports a variety of optional Probe conversions.
Magnetic surface temperature measurement Probe through strong magnetic adsorption on the workpiece, small volume and light mass, Sensor and magnet insulation to ensure measurement accuracy, the highest temperature 480 ℃, especially suitable for circular workpiece surface.
Single point temperature measurement design, temperature point 70 ℃, irreversible discoloration characteristics, anti-fouling protective film design, specification 2.5x4 cm, service life indoor 3 years.
The ring 6mm Probe design ensures good contact with the workpiece surface, the Teflon jacket is easy to clean and flexible and durable, the maximum temperature resistance is 300 ° C, and the lightweight shape avoids affecting the measurement accuracy.
Using 5MHZ Frequency and 10mm diaMeter Probe design, Measurement range 1.2-230 mm, the minimum pipe diaMeter can be measured Φ 20mm × 3mm, suitable for thickness detection in room temperature environment.
Automatically detect the drop point and softening point of amorphous polymer compounds, temperature resolution 0.1 ℃, heating rate adjustable eight gears, in line with ASTMD3461-97 standard, easy to operate and strong sense of cleanliness.
Measurement accuracy of +/- 0.2 ° C with 5-point factory calibrated and internal calibrated verification, folding stainless steel Probe to penetrate ingredients, IP67 waterproof housing to support float protection.
Measuring temperature, Humidity and dew point at the same time, dewpoint temperature range -40~ 40 ℃, with automatic memory function, digital LCD display ignore the difference, Sampling time is only 0.4 seconds, the structure is sturdy and portable.
Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.
Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.
Measurement accuracy of 1% F. S and 1 × 10~ 0.1M wide range, support 5 point calibrating, automatic temperature compensation and 500 data storage, built-in clock conforms to GLP specifications.
Measurement accuracy of +/- 1% F. S with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation to ensure measurement Stability and accuracy.
Adjustment with 5 point buttons, 8 Ion concentration calibrated point selection, Measurement accuracy of +/- 1% FS, automatic temperature compensation to ensure full scale accurate measurement, 500 data storage and GLP compliance.
Measurement accuracy of 0.5% F.S. with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation, suitable for a variety of Ion concentration unit selection.