Three-temperature zone light Incubator

The three-zone illuminated incubator uses independent temperature control systems to set different temperatures across three zones, combined with adjustable lighting to simulate environmental conditions. It is used for experiments such as plant growth and seed germination, allowing observation of biological responses under various combinations of temperature and light.
Selection
When selecting, consider the number of temperature zones and independent temperature control accuracy, the range and uniformity of light intensity, the material and sealing of the chamber, the convenience of the operation interface, as well as the spatial requirements and energy consumption parameters for actual experiments.

Terms

Instruments

The independent control of the dual temperature zone can simultaneously digest different paraMeters, the 30-hole design supports digestion capacity above 12mL, the temperature control accuracy is +/- 0.5 ° C, the temperature is raised to 165 ° C within 12 minutes, and the fully enclosed transparent protective cover ensures safety.

$ 1977.00

The three-box structure is used to achieve independent temperature control in the high temperature zone, low temperature zone and test zone, with a temperature conversion time of less than or equal to 10 seconds. It is equipped with rigid polyurethane foam insulation materials and supports 2 or 3 boxes of Impact mode to meet different standard testing requirements.

$ 12757.00

Adopt three-box heat storage and cold storage structure, temperature conversion time ≤ 10 seconds, Temperature range -65 ℃~ + 150 ℃, with independent temperature control functions in high temperature zone, low temperature zone and test zone, and can perform 2-box or 3-box Impact mode.

$ 20261.00

The three-box structure is used to realize the static test sample, the strong cooling hot air circuit switching technology, the temperature conversion time is less than or equal to 10 seconds, the temperature recovery time is less than or equal to 5 minutes, and the temperature control function is independent in the high temperature zone, the low temperature zone and the test zone.

$ 15032.00

800L large-capacity liner, three-sided light without dead angle design, temperature control accuracy +/- 1 ℃ and support day and night different settings, six-level adjustable light intensity, support up to 360 hours of continuous and stable operation.

$ 6136.00

The three-box structure realizes independent temperature control in the high temperature zone, the low temperature zone and the test zone. The temperature conversion time is within 10 seconds, and the temperature control accuracy reaches +/- 0.5 ° C. The air circuit switching method is used for rapid Impact testing to improve the material testing efficiency.

$ 30217.00

The Three-Box structure is used to distinguish the high temperature zone, the low temperature zone and the test zone, and the air passage is switched to achieve temperature impact. The maximum cycle period is 9999 times, and the Temperature range is -60~ 150 ° C. It supports automatic cycle or manual selective impact.

$ 8695.00

The three-box heat storage and cold storage structure is adopted to achieve rapid temperature conversion of ≤ 10s, and the temperature recovery time is ≤ 5 minutes. It supports Impact testing at 150 ° C in high temperature zone and -40 ° C in low temperature zone, and has program memory and Linear dispersion recording functions.

$ 17307.00

The three-box structure realizes the separation of the high temperature zone, the low temperature zone and the test zone, the air passage switching mode intRoduces the temperature for Impact, the temperature conversion time is ≤ 10 seconds, the temperature control accuracy is +/- 0.5 ℃, and the microcomputer equilibrate temperature control system and the double-stage Compressor chill down.

$ 10240.00

With three-sided lighting system and six-level dimming function, Temperature Fluctuation +/- 1 ℃, supports 99 cycles of programming control, and can run continuously for no less than 360 hours to meet the needs of complex experiments.

$ 1340.00

The three-box structure design realizes the rapid switching between the high temperature zone of 60 ° C to 150 ° C and the low temperature zone of -10 ° C to -45 ° C. The temperature conversion only takes 10 seconds to complete, and the temperature recovery time does not exceed 5 minutes. The air circuit switching method is used to ensure the test Stability.

$ 25215.00

The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.

$ 373.00

With three light source system, color rendering index up to 98, all metal structure with three drawer, table size 1350 * 900mm, in line with ISO3664 international standards.

$ 2365.00

The three-box heat storage structure is used to realize forced air circuit switching, the temperature recovery time is less than or equal to 5 minutes, and the conversion only takes 10 seconds. With independent temperature control in high temperature zone, low temperature zone and test zone, it can perform 2-box or 3-box Impact mode to meet different test needs.

$ 17759.00

Adopting mirror stainless steel liner and unique air duct circulation to ensure Temperature Uniformity +/- 1.5 ℃, 24-stage program can be set to simulate day and night changes, support 0~ 12000LX four-level adjustable light, safe temperature limit alarm.

$ 1369.00