Interfacial Tension RheoMeter

Interfacial tension rheometers analyze the viscoelasticity and tension changes of liquid interfaces by measuring their stress responses under shear or oscillation. They are used in industries such as coatings and inks for evaluating emulsion stability and testing surfactant performance, helping to control product coating and film formation processes.
Selection
When selecting, consider that the measurement range should cover the actual tension values of the samples, the temperature control should match the process conditions, and the modules should be compatible with rotation/oscillation modes. Pay attention to the instrument's accuracy and repeatability data, and ensure the operation software supports real-time curve analysis. Choose different ring/plate measurement probes based on the properties of the samples.

Terms

Standards

Instruments

Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.

$ 3331.00

Adopt electromagnetic force closed-loop measurement system, accuracy +/- 0.02mN/m, support 0-200mN/m range measurement, with automatic lifting and temperature detection functions, can test high viscosity liquids and dynamic surface tension changes.

$ 4458.00

Measurement range 0-200mN/m, resolution 0.01mN/m, with standard weight and standard material double calibrated, 32-bit ARM control to ensure operation accuracy, automatic stop and average function to improve operation efficiency.

$ 1332.00

The manual lifting platform is equipped with fast fine-tuning dual gear, supports platinum plate method and ring method dual Measurement mode, Measurement range 0-400mN/m, error is only +/- 0.1mN/m, can be connected to the computer to display the tension change in real time Linear dispersion.

$ 1531.00

Measurement range 0~ 180mN/m, accuracy 0.1mN/m, pure mechanical structure design, durable and easy to operate, suitable for teaching and laboratory use.

$ 961.00

Adopt ring test method, support standard weight and standard medium double calibration, Measurement range 0-200mN/m, accuracy +/- 1% FS, with automatic stop and average function, Repeatability is good.

$ 1526.00

Measurement range 0-500.0mN/m, accuracy 0.01mN/m, equipped with quartz glass strong acid and alkali resistance, automatic zero to maintain peak value, automatic calculation of Correction factor and average value, repeatability error is not greater than +/- 0.2%.

$ 1429.00

Equipped with quartz glass, suitable for strong acid and alkali solution testing, Measurement range 0-200mN/m, Accuracy 0.01mN/m, automatic zero adjustment, peak holding and result calculation, repeatability error is not greater than +/- 0.2%.

$ 977.00

Measurement range 0~ 200mN/m, standard error +/- 0.03mN/m, support real-time Linear dispersion display and thermostatic control, easy and reliable operation.

$ 2207.00

Measurement range 0-200mN/m, resolution 0.01mN/m, Automatic Correction factor calculation, Accurate test and Good Data Repeatability, Equipped with quartz glass to adapt to strong acid and alkali environment.

$ 2187.00

With a fully automatic liquid inlet device, the liquid inlet accuracy reaches 0.001 μL, equipped with SONY high-speed industrial-grade chip and a variety of Measuring methods, it can accurately measure 0-180 ° contact angle and 0-3000mN/m surface tension to meet various material surface performance analysis requirements.

$ 5495.00

It can accurately test the surface tension value of the material, support a variety of specifications bottle selection, the test range covers 30-60 dynes, suitable for Plastic film, metal foil and other materials surface tension detection.

$ 87.00

Ring test and reference material correction, resolution 0.01mN/m, equipped with 24-bit AD converter and LVDT displacement Sensor, support automatic stop and averaging functions to ensure test Linearity and repeability accuracy.

$ 1397.00

Measurement principle using three rounds of tension, accuracy +/- 1.5%, 62 measurements per second, support current value, MAX Maximum, peak, MIN Minimum display, optional USB or Bluetooth data output, automatic shutdown function.

$ 446.00

Measurement principle of three rounds of tension, 62 measurements per second, accuracy +/- 1.5%, support a variety of unit conversion and automatic shutdown, optional USB or Bluetooth data output.

$ 446.00

Articles

Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
Melt Flow Indexer and Torque Rheometer in the Evaluation of Processing Properties of Thermoplastic Resins
This article introduces the differences and selection methods between melt indexers and torque rheometers in evaluating the processing properties of thermoplastic resins.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rheometer combined with UV light source to study the curing behavior of photopolymerizable resin
This article introduces how to combine a rheometer with a UV light source to study the curing process of UV-curable resins.
Capillary Rheometer for Determining the Shear Viscosity Curve of Hot Melt Adhesives
This article introduces the method of measuring the shear viscosity curve of hot melt adhesives using a capillary rheometer. The principle involves pushing molten hot melt adhesive through a capillary, measuring the pressure and flow rate, and then calculating the shear stress and viscosity.
Can you distinguish between a rotational viscometer, a rheometer, and a cone-plate viscometer?
Rotational viscometers, rheometers, and cone-plate viscometers are core instruments in the field of material characterization, with significant differences in measurement principles, geometric structures, and functional positioning.