Resistance Heat Treatment Furnace

Resistance heat treatment furnaces generate heat by passing an electric current through resistance elements to heat materials. They are used for processes such as heat treatment, drying, and curing of materials, and are employed in industries like coatings, plastics, and papermaking to enhance material properties.
Selection
When selecting a resistance heat treatment furnace, it is necessary to consider the matching of the heating temperature range with material requirements, the adaptability of the furnace chamber size to the sample dimensions, the compliance of temperature control accuracy with process requirements, the alignment of energy consumption with usage costs, and the completeness and reliability of safety protection devices.

Terms

Standards

Instruments

The maximum temperature is 1200 ℃, the Furnace volume is 2L, the microcomputer PID controller is used for precise temperature control, the door sealing design enhances Temperature uniformity, and the corrosion resistance refractory brick Furnace is durable.

$ 838.00

Maximum temperature of 1300 ℃, temperature control accuracy +/- 1 ℃, equipped with microcomputer PID controller to achieve accurate temperature control, Furnace door safety switch automatic power off to ensure safe operation, corrosion Furnace to ensure durability.

$ 2150.00

Maximum temperature up to 1600 ℃, temperature control accuracy +/- 1 ℃, equipped with microcomputer PID controller to achieve multi-stage programming, Furnace door safety switch automatic power off, provide refractory brick and ceramic fiber two Furnace options.

$ 7475.00

The maximum temperature is 1600 ° C, the temperature control accuracy is +/- 1 ° C, equipped with 10-stage program control, and the safety switch of the Furnace door is automatically powered off to ensure operation safety and Temperature uniformity.

$ 6785.00

The maximum temperature is 1200 ° C, the Furnace volume is 16L, and the 30-segment programmable control is used to achieve precise temperature control. The safety switch of the Furnace door and the design of the corrosion resistance Furnace improve the operation safety and durability.

$ 1716.00

With 30 programmable control function, the maximum temperature can reach 1000 ℃, Furnace volume 7L, automatic power-off protection when opening the door, good sealing of the Furnace door and small heat loss.

$ 1046.00

The highest temperature up to 1000 ℃, Furnace volume 16L, the use of refractory brick Furnace and wirecoil for heater heating, with automatic safety switch and overheating and overpressure protection, Furnace door sealing good heat loss is small.

$ 1145.00

Maximum temperature up to 1200 ℃, Furnace volume 16L, microcomputer PID control to ensure accurate and stable temperature, unique Furnace door design to enhance sealing to reduce heat loss, refractory brick Furnace and nickel-chrome wire heating elements to provide long-term durability.

$ 1460.00

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the refractory brick Furnace and the unique Furnace door design, the heat loss is small and the temperature is uniform, with a variety of Safety protection measures.

$ 1430.00

With 30-stage programmable control function, the maximum temperature is 1000 ℃, the Furnace volume is 2L, the refractory brick Furnace and stainless steel material are used, and the heat loss is small and the Temperature uniformity is good.

$ 927.00

Three-sided heating method to ensure uniform temperature, PID microcomputer and precision Sensor combination to achieve +/- 5% ℃ temperature control accuracy, closed aluminum silicate Furnace to reduce heat loss, support 0~ 9999 minutes timing and a variety of operating modes.

$ 990.00

With two-way door design to effectively prevent hot gas leakage, 30-stage multi-stage programmable control to achieve accurate temperature control cycle, Furnace Temperature uniformity and corrosion resistance, the maximum temperature 1200 ℃ Power 2.5KW.

$ 1046.00

The refractory brick Furnace has excellent thermal insulation performance, is equipped with 50-stage program temperature control system, Temperature Fluctuation +/- 2 ℃, supports over-temperature alarm and timing function, and the Furnace volume is 7.2L to ensure the safety and stability of the experiment.

$ 1009.00

With 30 programmable control function, support heating or stay setting, stainless steel Furnace door and microcomputer PID controller, to ensure accurate and reliable temperature control, Furnace Temperature uniformity.

$ 1313.00

Using wirecoil for heater heating components and refractory brick Furnace, the maximum temperature is 1000 ℃, the Furnace volume is 2L, with multiple Safety protection measures such as overcurrent, overpressure and overheating.

$ 740.00

Articles

How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Four-probe resistivity tester measures the sheet resistance of conductive polymer films.
This article introduces the method of measuring the sheet resistance of conductive polymer films using a four-probe resistivity tester. Sheet resistance is an important parameter for evaluating the conductivity of films.
Insulation resistance tester measures rubber sealing gaskets.
This article introduces the method of using an insulation resistance tester to inspect rubber sealing gaskets.
Considerations for Channel Count and Temperature Endurance in Furnace Temperature Tracker Selection
When selecting a furnace temperature tracker, the main considerations are the number of channels and the temperature resistance duration. The number of channels is determined based on the quantity of temperature measurement points plus spare channels. Too few channels may lead to data loss, while too many channels can increase costs.
Resistance meter selection testing frequency and material conductivity range
This article primarily discusses how to consider test frequency and material conductivity range when selecting a resistivity meter.
The heating film coater applies thick-film resistor paste onto the ceramic substrate.
The heating coating machine is used to apply thick film resistor paste on ceramic substrates. It reduces the viscosity of the paste through a heating platform and ensures uniform coating in conjunction with the coating head.
Muffle furnace is used for the determination of coating loss on ignition and ash content.
A muffle furnace is a laboratory heating device used to determine the loss on ignition and ash content of coating materials. By incinerating the sample at high temperatures, the organic components decompose and volatilize, leaving behind inorganic residues as ash.
Muffle Furnace Ash Test Method for Determination of Inorganic Filler Residues in Varnish
This article introduces the method of using the muffle furnace ash test to determine the residual amount of inorganic fillers in varnish. The inorganic substances in varnish can affect the performance of the coating, making accurate determination of ash content important for quality control.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
The Invisible Impact of Abnormal Resistivity on the Performance of Specialty Papers
This article discusses the impact of resistivity on the performance of specialty paper. Resistivity reflects the conductivity of the paper, and its abnormal fluctuations may be caused by factors such as changes in raw material ratios, fillers, or the production environment.
Porosity Control in the Preparation of Porous Coatings During the Blade Coating Process
Doctor blade coating is a wet coating technique widely used for preparing functional coatings, which involves uniformly applying a slurry containing solid particles (such as ceramics, polymers, or metal oxides) onto a substrate, followed by drying and heat treatment to form the coating.
The versatile electric furnace is still being used as a hot plate, but 90% of people are unaware of these hidden functions.
In addition to basic heating, the universal electric furnace has many practical functions that are often overlooked. It features a built-in temperature control system that allows for programmed automatic heating, making it suitable for experiments requiring precise temperature control.