SS Tube Thickness Gauge

The stainless steel pipe thickness gauge utilizes the principle of ultrasonic waves propagating and reflecting within the material, measuring the round-trip time of the sound waves to calculate thickness. It is used to inspect pipe wall thickness to ensure compliance with specifications, commonly employed in industrial pipeline maintenance and quality control.
Selection
When selecting, consider the measurement range covering the pipe thickness, accuracy meeting requirements, probe compatibility with curved surfaces, environmental durability such as dust and water resistance, ease of operation, and convenience of calibration and maintenance.

Terms

Standards

Instruments

Using 90 ° Measurement Angles and eddy Current principles, accurate measurement of edge coatings, narrow tube coatings and small surface areas ensures stable and reliable measurement on complex geometries.

$ 235.00

Using 90 ° Measurement Angles and magnetic Induction principles, accurate measurement of edge coatings, narrow tube coatings and small surface areas ensures measurement accuracy and Stability.

$ 167.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Measurement range 0-12mm, Accuracy of 1-3%, Support automatic identification of matrix material and continuous Measurement mode, suitable for pipeline anticorrosive layer defect location.

$ 696.00

Suitable for inner paper tube testing with an outer diaMeter of 400mm, with a capacity of 500kg and an adjustable speed of 10-80mm/min, it automatically judges the crushing force and supports data printing function.

$ 1727.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Double shell structure with Air-Cooled system to achieve rapid cooling, 51 program temperature control system to ensure +/- 1 ℃ accuracy, the highest Operating temperature of 1700 ℃ and equipped with corundum tube to ensure high temperature Stability.

$ 3640.00

Equipped with 40 0.2ml independent tube positions, compatible with 8 * 0.2 tubes, high-quality materials are used to ensure sample safety and easy operation.

$ 127.00

Double shell structure with cold air system to achieve rapid cooling, 51 program temperature control system to ensure +/- 1 ℃ accuracy, the highest Operating temperature of 1700 ℃, corundum Furnace tube high temperature performance.

$ 4543.00

With emission-echo and echo-echo two thickness measurement modes, Measurement range 0.65~ 600mm, Probe type can be automatically identified and zero point calibrated, support anti-measurement Speed of sound function to improve accuracy.

$ 667.00

Measurement range 0.8~ 300mm, accuracy up to +/- 0.04mm, support high-speed measurement 10 times/second, portable design for field use.

$ 706.00

Measurement of nonmagnetic coatings on ferrous metals, thickness range 0-6000μm, accuracy +/- 3%, built-in Probe single-handed operation, Protection Rating IP65, 60 + readings per minute.

$ 1022.00

Measurement range 1.2~ 225mm, support Speed of sound measurement and 12 data storage functions, with upper and lower limit alarm settings and coupling status prompts, suitable for a variety of material thickness detection.

$ 223.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Visual color comparison method using colorimetric tubes to determine the color phase of varnish.
Colorimetric tube visual colorimetry is a method used to determine the color hue tendency of varnish samples by directly comparing them with a standard color scale using the human eye. During operation, samples and standard liquid columns should be prepared using colorimetric tubes of consistent specifications under standard lighting conditions, and the hue differences should be observed in parallel.
Daily Maintenance and Common Troubleshooting Guide for Titrators in the Laboratory
This guide introduces the daily maintenance and common troubleshooting methods for titrators. Daily maintenance includes cleaning and sealing checks of burettes and liquid pathways, proper storage and performance verification of electrodes, as well as inspections of the instrument's external environment and mechanical components.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.