Low-temperature thermostatic liquid Bath

The low-temperature constant temperature liquid bath uses a refrigeration system to control the temperature of the liquid in the bath, allowing samples to be tested in a constant low-temperature environment. It is used in laboratories to detect the performance of materials at low temperatures, such as determining the freezing point of coatings or testing the cold resistance of plastics, ensuring stable and reliable results.
Selection
When selecting a low-temperature constant temperature liquid bath, consider whether the temperature range covers the experimental needs, whether the temperature control accuracy meets the standards, whether the bath capacity is suitable for the sample size, the impact of cooling speed on efficiency, as well as the corrosion resistance of the equipment material and operational safety, to ensure long-term stability in use.

Terms

Standards

Instruments

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liter Tank and 8L/min Pump Flow rate, support liquid level alarm and computer communication, the inner Tank and the box are made of high quality stainless steel.

$ 1108.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet diverse experimental needs.

$ 942.00

Using non-fluorine environmental protection Compressor refrigeration, temperature fluctuation +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor and domestic circulation pump, to avoid its own heat generation affecting the temperature field uniformity, to ensure stable and reliable temperature control.

$ 861.00

The temperature fluctuation is controlled within +/- 0.05 ℃, the non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field, and multiple Safety protection devices are equipped to ensure stable and reliable operation.

$ 1237.00

The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ℃. Safety protection devices are equipped to ensure stable operation of the equipment and support external circulation functions to meet diverse experimental needs.

$ 1611.00

The double Compressor cascade refrigeration system is adopted, which has high refrigeration efficiency and low noise; the overall foaming and heat insulation of the Tank body reduces the loss of cooling capacity; Temperature Fluctuation +/- 0.05 ℃, Pump Flow rate 10L/min to ensure the uniformity of liquid in the Tank.

$ 2897.00

Microcomputer thermostatic Control system, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, two-way communication and liquid level alarm function, Pump Flow rate 10L/min.

$ 1889.00

The double Compressor cascade refrigeration system is adopted to ensure rapid cooling, and the overall foaming process of the low temperature Tank body reduces the loss of cooling capacity. Temperature Fluctuation +/- 0.05 ℃, Pump Flow rate 10L/min ensure the uniformity of liquid in the Tank.

$ 3414.00

Microcomputer thermostatic Control system, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, two-way communication, equipped with liquid level alarm and 6 liters stirring pump capacity 8L/min.

$ 1206.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, the temperature fluctuation is +/- 0.05 ℃, and it has low water level protection and Compressor multiple protection functions to ensure the safety and stability of the experiment.

$ 1067.00

It adopts transparent carbonic acid ester Bath design, with a volume of 6L, equipped with pressure/suction pump and Pt100 temperature sensor, with low liquid level protection and hardware over-temperature protection functions, and supports external circulation temperature control.

$ 1519.00

The non-heat centrifugal circulating pump is used to ensure uniform insulation field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices such as low water level anti-dry burning and Compressor overcurrent protection, optional temperature control and external Sensor to enhance application flexibility.

$ 4482.00

Double Compressor refrigeration system is adopted to ensure rapid cooling, Tank volume 6L, Pump Flow rate 8L/min to ensure liquid uniformity, Temperature Fluctuation is controlled within +/- 0.05 ℃, and the overall foaming process reduces cooling loss.

$ 946.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.