The Gamma ball volume replacement method is used to support 0.01-300 g weight range and 0.001g/cm ³ density accuracy, and the immersion depth of the liquid level can be adjusted arbitrarily and the air buoyancy error can be compensated.
The pre-pressurization technology is used to ensure the stable exudation of electrolysis liquid in viscous samples, the design of the ceramic core liquid network part effectively prevents blockage, and the membrane Impedance is less than 150MΩ, which is suitable for high temperature and high voltage environment testing.
The Gamma ball volume replacement method is used for the measurement of medium and high viscosity liquids with an accuracy of 0.001g/cm ³. The immersion depth can be adjusted arbitrarily and the air buoyancy error can be compensated. The test time only takes 10 seconds.
The Gamma ball impregnation volume replacement method is used to support 0.01-600 g sample range, density accuracy 0.001g/cm ³, adjustable immersion depth and compensation for air buoyancy error, and is suitable for medium and high viscosity fluid testing.
Pre-pressurization technology is used to ensure stable exudation of electrolysis solution in viscous samples, equipped with 3 ceramic core liquid network parts and Protelyte oily electrolysis solution, membrane Impedance < 200MΩ, effectively prevent protein settling blockage, suitable for high temperature and high voltage environment.
Pre-pressurization technology is used to ensure stable exudation of electrolysis in viscous samples, equipped with a three-ceramic core liquid network structure to reduce the risk of clogging, Protelyte oily electrolysis solution avoids reaction with proteins, membrane Impedance is less than 200MΩ, suitable for -5~ 100 ℃ Temperature range.
Pre-pressurization technology is used to prevent clogging of viscous samples, Protelyte oily electrolysis solution avoids protein reaction, ceramic core liquid network design, Temperature range -5~ 100 ℃, Membrane Impedance < 150MΩ.
Pre-pressurization technology is used to prevent clogging of viscous samples, Protelyte oily electrolysis solution avoids protein reaction, three ceramic core liquid network design, Temperature range 0~ 130 ℃, Membrane Impedance < 200MΩ.
Using pre-pressure technology to ensure stable exudation of electrolysis in viscous samples, equipped with Protelyte oily electrolysis solution to avoid protein reaction, membrane Impedance < 500MΩ, Temperature range 0~ 130 ℃, suitable for high temperature and high voltage environment.
Measurement range 0-14pH, temperature 5-60 ℃, equipped with removable protective foot, suitable for viscous sample measurement, fiber single salt bridge design to ensure measurement Stability.
Speed range 30-2200rpm, Max. Torque 60N.cm, can handle 50000mPa · s viscous liquid, with automatic overload protection and LCD screen display, support long-term continuous operation.
Cantilever structure to prevent liquid infiltration, large proportion of chilled down surface uniform heat dissipation, Speed range 60~ 2000rpm, Max. Torque 1850gcm, suitable for viscosity of 10000mPa · s liquid stirring.
Density accuracy of 0.001g/cm ³, maximum weighing 310g, built-in a variety of density reference can be customized settings, support solid liquid powder and other sample testing.
Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.
Pellon liquid junction is used to ensure uniform Flow velocity, circular Glass sensitive film fully senses pH value, Measurement range 0~ 14pH, Operating temperature 0~ 60 ℃, the structure is not easy to damage.