Temperature Measurement Recorder

Temperature measurement recorders sense environmental temperature changes through sensors, convert electrical signals into digital records, and continuously monitor temperature fluctuations in storage, transportation, and laboratory settings while generating data reports.
Selection
When selecting, consider that the measurement range covers the usage scenarios, the accuracy matches the requirements, the probe type is suitable for the measured medium, the battery life meets the recording cycle, the protection rating is appropriate for the environment, and the data export method is convenient and reliable.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

Waterproof depth of 120 Meters, suitable for long-term underwater deployment. Bluetooth low energy wireless connection, easy to set up and data download. Built-in large memory can store 98000 measurements, users can replace the battery by themselves. With water detection function to save power, Temperature Measurement accuracy is +/- 0.2 ℃.

$ 315.00

With built-in and external dual temperature sensors, the temperature range covers -40.0 to 125.0 ° C, IP67 waterproof and dustproof, supports data storage of up to 16,000 readings, and can prompt temperature abnormalities through LED alarms.

$ 272.00

Built-in High Accuracy Temperature Humidity Sensor, Temperature Error +/- 0.2 ℃, Humidity Error +/- 2.5%. Adopt Bluetooth low energy wireless transmission, support remote setting and data download, with weatherproof housing and NEMA6/IP67 Protection Rating, suitable for long-term outdoor monitoring.

$ 414.00

Bluetooth low energy wireless connection, easy to set up and download; waterproof depth of 1500 Meters, durable for long-term underwater deployment; built-in large memory can store 98000 measurement data; with water detection function to save Battery life.

$ 330.00

Capacitive polymer film Humidity Sensor and semiconductor temperature sensor, with temperature compensation and nonlinear correction function, can store 8000 sets of data, support USB connection and automatic calculation of average value, MAX Maximum and MIN Minimum, compact and easy to carry.

$ 294.00

Equipped with 7-inch IPS industrial touch screen and 32-bit high-speed MCU, Measurement accuracy up to 0.2 ° C, support 64 file storage and a variety of Thermocouple inputs, channel isolation voltage up to 350V, to ensure stable and reliable data collection.

$ 1913.00

Equipped with 7-inch IPS industrial touch screen, support 40 channels of independent measurement, basic accuracy 0.2 ℃ + 2 words, channel isolation voltage up to 350V, Modular design can be expanded to 64 channels.

$ 1558.00

Equipped with 7-inch IPS industrial touch screen and 32-bit high-speed MCU, Measurement accuracy 0.2 ℃, support up to 64 channel expansion, with multi-interface display and independent error correction function, strong anti-interference.

$ 1735.00

Using Bluetooth wireless communication, support setting and data reading through mobile phone or tablet within 30.5 Meters. The accuracy is up to +/- 0.2 ° C and +/- 2% RH, can store more than 84000 Measured values, and has sound and light alarm function.

$ 328.00

Equipped with 7-inch 1024 × 600 resolution IPS industrial screen, using 32-bit MCU + 24-bit AD chip to achieve 0.2 ℃ Measurement accuracy, support 64 file storage and single file 130,000 data, channel withstand voltage AC/DC 350V.

$ 1025.00

Support Bluetooth wireless setting and download, waterproof depth of 30 Meters, memory can store 96000 Measured values, users can replace the battery by themselves, and have temperature threshold LED alarm function.

$ 235.00

Equipped with 7-inch 1024 × 600 resolution touch screen, using 32-bit MCU and 24-bit AD chip, support 64-channel independent measurement, basic accuracy 0.2 ℃, channel voltage AC/DC 350V, with multi-interface display and long-term recording function.

$ 2090.00

Optical inspection dissolved oxygen Sensor technology, strong and durable, measurement depth of 100 Meters, accuracy of +/- 0.2mg/L (8mg/L). Probe removable replacement, easy maintenance, suitable for long-term underwater monitoring.

$ 2387.00

Using 32-bit high-speed MCU and 24-bit AD chip, Measurement accuracy of 0.2 ℃ + 2 word, support 64 channel expansion and 350V channel isolation, with a variety of Display modes and long-term recording capabilities.

$ 848.00

Using Bluetooth low energy technology, support wireless settings and data download, waterproof depth of 30 Meters, accuracy of +/- 0.5 ℃, Storage capacity of 98,000 measurements, users can easily replace the battery.

$ 202.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.