Torque and Angle Gauge

Torque-angle meters measure the torque and rotation angle data of rotating components through sensors, and are used to test the mechanical performance of assembly processes such as screw fastening and bottle cap sealing. In automotive manufacturing and electronic product assembly, they monitor the tightening process to ensure that connectors achieve the preset torque range.
Selection
When selecting, it is essential to match the torque range and accuracy requirements of the measured object, and consider the compatibility of the clamping method with the shape of the workpiece. Confirm whether the data output interface can connect to the existing system, and check the wear resistance of the sensor. Environmental factors, such as temperature fluctuations, should also be included in the assessment.

Terms

Standards

Instruments

With +/- 1% accuracy and 0.1 ° angle Graduation, it supports real-time stiffness display and 10 sets of data storage analysis, and the manual loading method is suitable for Φ 100mm rotary diaMeter specimens.

$ 1550.00

Measurement range 0~ 1250μm, error +/- 3%, minimum measurement surface F7mm, suitable for complex structure right angle measurement scene.

$ 469.00

Three-point contact design ensures 45 ° stability testing angle, equipped with 6B-6H pencil and 500g to 1000g adjustable load, manual push to achieve accurate film Hardness identification.

$ 162.00

Made of PUR material, compatible with drag chain design, suitable for a variety of right angle Probe models, providing stable signal transmission, suitable for coating thickness detection applications in industrial environments.

$ 262.00

Measurement accuracy of +/- 0.1 ° and angle resolution of 0.001 ° with SONY high-speed industrial-grade chip and 0.7-4 zoom Microscope head. Measurement modes such as seat drop method, forward angle and backward angle are supported, and 2 million test records can be stored.

$ 2897.00

Using injection defined bottom surface method for measurement, the funnel outlet has a diaMeter of Φ 5mm and a taper of 60 ° +/- 0.5 °, which can accurately measure the acute angle between the inclined surface of dust accumulation and the horizontal one.

$ 525.00

The injection limited bottom surface method is used to directly measure the angle of repose, the funnel taper is 60 ° +/- 0.5 °, and the outflow diaMeter is 5mm, which is suitable for powder flowability analysis of different particle sizes and shapes.

$ 545.00

Baseline and droplet contours are automatically recognized by machine vision, and contact angles are calculated based on Laplace equation quadratic Linear dispersion fitting. Measurement range is 0-180 °, accuracy is 0.1 °, and dynamic contact angle measurement and surface energy calculation are supported.

$ 3462.00

CCD camera system to achieve 1280 × 1024 resolution image analysis, support 0~ 180 ° contact angle and 0~ 400mN/m surface tension measurement, with dynamic contact angle analysis and solid surface energy estimation function.

$ 4077.00

The static drop method, droplet method and inclined plate method are used for measurement of dynamic contact angle, with automatic sampling, automatic surface tension analysis and automatic contact angle analysis functions. Degree of automation is high and Measurement accuracy is high.

$ 6205.00

Using 90 ° Measurement Angles and eddy Current principles, accurate measurement of edge coatings, narrow tube coatings and small surface areas ensures stable and reliable measurement on complex geometries.

$ 235.00

Carr Angle of Repose was determined by injection limited bottom surface method, funnel taper 60 ° +/- 0.5 °, outlet diaMeter 5mm can be customized 10mm, easy to operate, durable, can accurately reflect the powder flowability.

$ 493.00

With 20 °/60 °/85 ° three-angle simultaneous measurement, measurement range of 20 ° up to 0-2000Gs, 2.4-inch color screen and 3000mAh lithium battery, support data storage and Bluetooth connection, Stability is high and portable and durable.

$ 554.00

Measurement accuracy of +/- 0.1 °, support for dynamic contact angle analysis, equipped with High Accuracy Optical inspection swirl/spin table and 3 million pixel camera, can handle powder and superhydrophobic materials, database storage 2 million records.

$ 3753.00

Driven by compressed air, torque up to 80N.cm, start-up capacity with load, explosion-proof and spark-free design, safe operation from the environment, standard pressure Gauge and multi-specification Impeller optional.

$ 1311.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Haze meter detects haze on high-gloss coating surfaces
Haze is the phenomenon where a high-gloss coating surface causes a blurring of reflected images due to light scattering, which reduces visual clarity. A haze meter quantifies the haze value by measuring the intensity ratio between the specularly reflected light and the scattered light at specific small angles. The lower the value, the clearer the surface.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Combined Use of Iodine Value and Saponification Value to Assess Oil Quality
In the field of lipid analysis, iodine value and saponification value are two key chemical indicators that reflect the composition characteristics of oils and fats from different perspectives.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.