Coating/Plating Thickness Tester

The film thickness gauge measures the thickness of coatings on substrates through magnetic induction, eddy current, or ultrasonic principles. The magnetic induction method is used for non-magnetic coatings on steel substrates, the eddy current method measures insulating layers on non-ferrous metal substrates, and the ultrasonic method is suitable for multi-layer structures. It is used to detect the thickness of paints, electroplating, and plastic films, ensuring coating uniformity.
Selection
When selecting a coating thickness gauge, it is necessary to confirm the substrate type (magnetic/non-magnetic), measurement range and accuracy, and the shape of the object to be measured (flat/curved). Consider the probe size to ensure it fits the measurement area and verify the instrument's calibration certificate. Environmental factors such as temperature and humidity affect measurement stability. Portable models are suitable for on-site inspections, while benchtop models are ideal for fixed samples in the laboratory.

Terms

Standards

Instruments

The wet film thickness can be as low as 1.5 μm, the groove bottom is wider to provide greater Coating Weight, the chrome plating surface and extrusion process ensure durability and easy cleaning, avoiding the problem of traditional steel wire loosening.

$ 477.00

The formed pRoduction process ensures stable structure, wet film thickness can be controlled to 100μm, chrome plating surface preparation improves Abrasion Resistance and ease of cleaning, and the effective application width reaches 500mm.

$ 231.00

The wet film thickness can be controlled to 1.5μm, the bottom of the groove is wider and the Coating Weight is larger, and the 304 stainless steel material and chrome-plated surface are used, which is durable and easy to clean, and avoids the problem of loose and broken wires.

$ 477.00

Lame plating movement rate 1-300mm/s, accuracy +/- 1%, support maximum 600 * 300mm substrate, can spray thickness 0.01~ 13mm, with 1L stainless steel pressure bucket, 5 inch touch screen control, energy consumption is only 100W.

$ 3623.00

With lame plating and scraping dual functions, Spreader speed 0-5m/min, Spreader width 100-300mm, integrated automatic tension control and correction system, support 0-200mm lame plating height adjustment to ensure coating uniformity and ease of operation.

$ 19438.00

Using reciprocating lame plating technology, the effective lame plating area of 160 × 80mm can be expanded to 200 × 100mm. Support 0.1-5 ml/min precision discharge control, with Vacuum chuck platform to ensure the substrate is flat. Integrated PLC and Touchscreen realize paraMeter preset and real-time monitoring.

$ 4108.00

Equipped with double spray guns to achieve uniform lame plating, the lifting range of the spray gun is adjustable from 10-500mm, the integrated air filtrate adjustment system supports magnetic or vacuum panel fixing, and improves the coating test Repeatability.

$ 67560.00

With lame plating and scraping dual functions, coating speed 0-5m/min adjustable, equipped with UV light curing system, curing area 300 * 1000mm, support automatic tension control and deviation correction function.

$ 29120.00

Can achieve a minimum of 1.5μm wet-film ultra-thin Spreader, wider groove bottom to bring greater Coating Weight, using extrusion process and chrome plating surface preparation, effective application width of 2000mm.

$ 477.00

The minimum wet film thickness can be controlled by 1.5μm, the bottom of the groove is wider and the Coating Weight is larger, and the extrusion process and chrome plating surface are used, which is easy to clean and durable.

$ 264.00

Adopt bar Spreader and automatic lame plating method, coating speed 5~ 180mm/s, heating Temperature range RT +~ 200 ℃, support Vacuum chuck and automatic feeding function, ensure Spreader uniformity and Stability.

$ 8465.00

Using extrusion process and chrome plating surface, the minimum wet film thickness can be controlled by 1.5 μ m, the bottom of the groove is wider and the Coating Weight is large, it is not easy to loosen and break the wire and is easy to clean.

$ 477.00

Using extrusion process and chrome plating surface, the minimum wet film thickness is 1.5 μm, the groove design is wide and not easy to block, and the length and shape can be freely customized to improve the uniformity and durability of Spreader.

$ 477.00

Using extrusion process and chrome plating surface preparation, the minimum wet film thickness can be controlled by 1.5μm. The groove design is wider than that of traditional pRoducts, and the Coating Weight is larger and not easy to block.

$ 525.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Peel strength tester measures interlayer force of composite films.
This article introduces how a peel strength tester measures the interlayer bonding force of composite films. Composite films are widely used in packaging and other fields, and their interlayer peel strength is a key indicator for evaluating durability.
Friction Coefficient Tester Measures the Slip and Openability of Films
This article introduces how to use a coefficient of friction tester to measure the slipperiness and openability of films. Slipperiness refers to the sliding characteristics of the film surface, while openability indicates the ease of separation between film layers. Both are crucial for processing efficiency in industries such as packaging.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.