Liquid dissolved oxygen

Dissolved oxygen in liquids refers to the concentration of oxygen molecules dissolved in water, detected through electrochemical or optical sensors that measure changes in oxygen levels. It is used to monitor the oxygenation status of water bodies, ensuring an oxygen-rich environment for aquaculture, wastewater treatment, and fermentation processes.
Selection
When selecting a liquid dissolved oxygen instrument, consider a measurement range that covers actual needs, a sensor type suitable for medium characteristics, a response speed matching monitoring frequency, a calibration method that facilitates maintenance, a protection rating that meets the usage environment, and data interfaces compatible with existing systems.

Terms

Standards

Instruments

Using high density polyethylene (PE) oxygen permeable membrane to achieve efficient oxygen diffusion, equipped with ABS plastic screw cap structure for easy installation and electrolysis filling, and interact with the current system for accurate measurement of dissolved oxygen concentration.

$ 243.00

The use of PTFE oxygen permeable membrane to ensure oxygen permeability, spiral cap design for easy installation and electrolysis filling, suitable for Portable dissolved oxygen measurement equipment maintenance.

$ 243.00

Measurement range of 50ppm dissolved oxygen and 600% Saturation, support pressure, temperature and salinity automatic compensation, can be used continuously for about 200 hours, with IP67 waterproof rating.

$ 1409.00

Optical inspection fluorescence technology for measurement of dissolved oxygen, no polarization time, fast Response and not affected by Flow velocity; Built-in temperature sensor, Measurement range 0.00-50 mg/L, accuracy up to 1.5% +/- 0.01mg/L; Protection Rating IP68, suitable for harsh environments.

$ 3401.00

Polarography dissolved oxygen Measurement range 0.00~ 50.00mg/L, Response Time ≤ 45s, support automatic temperature compensation and salinity compensation, with IP65 Protection Rating, Data storage 500 sets and GLP standards.

$ 674.00

With pH, ORP, dissolved oxygen three measurement functions, support automatic temperature compensation and salinity compensation, built-in 500 data storage, equipped with USB Communication interface, Measurement accuracy of +/- 0.002pH.

$ 630.00

PTFE oxygen permeable membrane ensures oxygen permeability, ABS plastic material enhances durability, screw cap design simplifies installation process, suitable for long-term water quality monitoring applications.

$ 243.00

With 7-inch TFT display and 1000 sets of data storage, support automatic temperature, salinity and atmospheric pressure compensation, Measurement range 0.00~ 20.00mg/L, accuracy +/- 0.2mg/L, suitable for a variety of dissolved oxygen related paraMeters determination.

$ 612.00

Support conductivity 0-200mS/cm and dissolved oxygen 0-20mg/L measurement, with automatic temperature compensation, ElectRode diagnostic function and IP54 Protection Rating, Data storage up to 450 groups and support Bluetooth printout.

$ 841.00

Can simultaneously measure pH, dissolved oxygen and temperature paraMeters, support automatic temperature compensation and ElectRode diagnosis, data storage capacity of 450 groups, with statistical analysis and Bluetooth printing function, dustproof and waterproof grade IP54.

$ 812.00

Built-in three measurement units can simultaneously detect pH, Conductivity Detector and dissolved oxygen, support automatic temperature compensation and ElectRode diagnosis, with IP54 Protection Rating, data storage capacity of 500 groups, support GLP specification to achieve data traceability.

$ 1142.00

Equipped with polarographic dissolved Oxygen electRode, Measurement accuracy +/- 0.5mg/L, support automatic temperature compensation and manual salinity compensation, full waterproof design to ensure harsh environment use, built-in a number of custom paraMeter settings.

$ 361.00

Using PTFE oxygen permeable membrane, the probe cathode and anode are isolated from the sample, and oxygen passes through the membrane and acts with the polarographic system to generate current to ensure accurate and reliable measurement.

$ 299.00

With conductivity 0-2000mS/cm and dissolved oxygen 0-20mg/L wide range measurement, support automatic temperature compensation and air pressure compensation, 3.5 inch color screen display, data storage capacity of 3000 groups, Protection Rating is IP57.

$ 670.00

Sterling silver cathode and zinc anode construction, integrated temperature sensor for instant measurement without conditioning time, thin permeable membrane isolates Sensor and allows oxygen to pass, generating current to determine oxygen concentration.

$ 162.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Application of Paper Absorbency Tester in Sizing Process
The paper absorbency tester evaluates the absorption performance of paper by measuring the penetration of liquid on the paper. In the sizing process, sizing agents alter the hydrophilicity of the paper fiber surface, thereby affecting the paper's resistance to liquids.
Water Absorption Tester in the Detection of Tissue Paper and Paperboard
This article introduces the application of water absorption testers in the testing of tissue paper and paperboard. The instrument evaluates the water absorption performance of materials by measuring the mass or height of liquid absorbed by the sample, with common methods including the Klemn method and the capillary rise height method.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.