Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.
Adopt electromagnetic force closed-loop measurement system, accuracy +/- 0.02mN/m, support 0-200mN/m range measurement, with automatic lifting and temperature detection functions, can test high viscosity liquids and dynamic surface tension changes.
The manual lifting platform is equipped with fast fine-tuning dual gear, supports platinum plate method and ring method dual Measurement mode, Measurement range 0-400mN/m, error is only +/- 0.1mN/m, can be connected to the computer to display the tension change in real time Linear dispersion.
With a fully automatic liquid inlet device, the liquid inlet accuracy reaches 0.001 μL, equipped with SONY high-speed industrial-grade chip and a variety of Measuring methods, it can accurately measure 0-180 ° contact angle and 0-3000mN/m surface tension to meet various material surface performance analysis requirements.
Measurement range 0~ 200mN/m, standard error +/- 0.03mN/m, support real-time Linear dispersion display and thermostatic control, easy and reliable operation.
Measurement range 0-200mN/m, resolution 0.01mN/m, with standard weight and standard material double calibrated, 32-bit ARM control to ensure operation accuracy, automatic stop and average function to improve operation efficiency.
Measurement range 0~ 180mN/m, accuracy 0.1mN/m, pure mechanical structure design, durable and easy to operate, suitable for teaching and laboratory use.
Adopt ring test method, support standard weight and standard medium double calibration, Measurement range 0-200mN/m, accuracy +/- 1% FS, with automatic stop and average function, Repeatability is good.
Measurement range 0-500.0mN/m, accuracy 0.01mN/m, equipped with quartz glass strong acid and alkali resistance, automatic zero to maintain peak value, automatic calculation of Correction factor and average value, repeatability error is not greater than +/- 0.2%.
Equipped with quartz glass, suitable for strong acid and alkali solution testing, Measurement range 0-200mN/m, Accuracy 0.01mN/m, automatic zero adjustment, peak holding and result calculation, repeatability error is not greater than +/- 0.2%.
Measurement range 0-200mN/m, resolution 0.01mN/m, Automatic Correction factor calculation, Accurate test and Good Data Repeatability, Equipped with quartz glass to adapt to strong acid and alkali environment.
Ring test and reference material correction, resolution 0.01mN/m, equipped with 24-bit AD converter and LVDT displacement Sensor, support automatic stop and averaging functions to ensure test Linearity and repeability accuracy.
Using platinum plate method measurement surface tension, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system, measurement process without vibration interference, support dynamic speed adjustment and a variety of Data analysis functions.
Temperature range 5~ 60 ℃, can correct liquid temperature, avoid surface tension test error caused by temperature change, suitable for High Accuracy sample thermostatic control requirements.
Can accurately test whether the surface tension of the material is up to standard, support a variety of specifications bottled liquid, provide red blue and other Color selection, suitable for Plastic film and conductive material detection.