Film Interfacial TensioMeter

The thin film interfacial Tensiometer calculates the interfacial tension between a liquid and a thin film by measuring the contact angle formed by the liquid on the solid film surface. It is used to evaluate the wettability of thin films and the adhesion of coatings, with applications in plastic printing and quality testing of composite packaging materials.
Selection
Select the appropriate instrument range based on the thickness of the film to be tested, consider whether automatic or manual liquid dispensing functions match operational requirements, confirm whether the instrument can test curved film surfaces, and verify that the temperature control range aligns with the material storage environmental conditions.

Terms

Standards

Instruments

Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.

$ 3331.00

Ring test and reference material correction, resolution 0.01mN/m, equipped with 24-bit AD converter and LVDT displacement Sensor, support automatic stop and averaging functions to ensure test Linearity and repeability accuracy.

$ 1397.00

Measurement range 0-200mN/m, accuracy +/- 0.02mN/m, support Automatic calibration and temperature compensation, real-time display test Linear dispersion and export Excel data.

$ 4188.00

Using platinum ring measurement, accuracy of 0.1mN/m, equipped with electronic level and automatic lifting system, eliminate vibration effects, support dynamic measurement and data management, to ensure experimental Repeatability and accuracy.

$ 2842.00

Using platinum ring measurement, accuracy of 0.001mN/m, lifting speed of 0~ 300mm/min adjustable, built-in electronic level and automatic measurement program to ensure data accuracy and Repeatability.

$ 6260.00

Measurement range 0-400mN/m, accuracy up to 0.1mN/m, support Automatic calibration and temperature compensation, real-time display of test Linear dispersion and export of Excel data.

$ 3107.00

Using platinum ring measurement, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system to ensure stable and reliable measurement process, support dynamic smooth operation to reduce vibration interference.

$ 3886.00

Using platinum plate method measurement surface tension, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system, measurement process without vibration interference, support dynamic speed adjustment and a variety of Data analysis functions.

$ 3886.00

Measurement range 0-200mN/m, resolution 0.01mN/m, with standard weight and standard material double calibrated, 32-bit ARM control to ensure operation accuracy, automatic stop and average function to improve operation efficiency.

$ 1332.00

Measurement range 0~ 180mN/m, accuracy 0.1mN/m, pure mechanical structure design, durable and easy to operate, suitable for teaching and laboratory use.

$ 961.00

Adopt electromagnetic force closed-loop measurement system, accuracy +/- 0.02mN/m, support 0-200mN/m range measurement, with automatic lifting and temperature detection functions, can test high viscosity liquids and dynamic surface tension changes.

$ 4458.00

Adopt ring test method, support standard weight and standard medium double calibration, Measurement range 0-200mN/m, accuracy +/- 1% FS, with automatic stop and average function, Repeatability is good.

$ 1526.00

Measurement range 0-500.0mN/m, accuracy 0.01mN/m, equipped with quartz glass strong acid and alkali resistance, automatic zero to maintain peak value, automatic calculation of Correction factor and average value, repeatability error is not greater than +/- 0.2%.

$ 1429.00

Using platinum plate method measurement, accuracy of 0.1mN/m, equipped with 7-inch Touchscreen and electronic level, support automatic lifting and data management, to ensure stable and reliable measurement.

$ 2842.00

Equipped with quartz glass, suitable for strong acid and alkali solution testing, Measurement range 0-200mN/m, Accuracy 0.01mN/m, automatic zero adjustment, peak holding and result calculation, repeatability error is not greater than +/- 0.2%.

$ 977.00

Articles

Detection Methods and Standards for Ozone Aging Tests on Thin Films
This article primarily introduces the aging test method for thin-film materials in an ozone environment.
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
Discussion on the Relationship Between Speed Gradient and Film Thickness in Spin-Coating Film Formation
Spin coating is a common technique that uses centrifugal force to evenly spread droplets across a substrate to form a thin film. The film thickness is influenced by multiple factors, among which the gradient of spin speed and time is a key parameter. This study, based on fluid mechanics principles and experimental validation, analyzes the quantitative effect of the spin speed gradient on film thickness.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Vacuum adsorption coating machine solves the flatness challenge in the transfer of ultra-thin graphene films.
The vacuum adsorption coating machine transfers graphene films smoothly onto target substrates through controlled negative pressure, solving issues such as wrinkling, tearing, and contamination often encountered with traditional methods.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
Friction coefficient meter adjusts the control of film slip agent addition.
This article introduces how to use a coefficient of friction meter to adjust the amount of slip agent added in film production.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Four-probe resistivity tester measures the sheet resistance of conductive polymer films.
This article introduces the method of measuring the sheet resistance of conductive polymer films using a four-probe resistivity tester. Sheet resistance is an important parameter for evaluating the conductivity of films.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Xenon lamp aging test chamber for testing film weather resistance.
This article introduces how a xenon lamp weathering test chamber tests the weatherability of films. It uses a xenon lamp to simulate sunlight and controls conditions such as temperature and humidity to accelerate the aging process of the film, thereby evaluating its performance changes in outdoor environments.