Total Nitrogen Water Quality Online Automatic Monitor

The Total Nitrogen Water Quality Online Automatic Monitor converts organic nitrogen in water samples into nitrate through ultraviolet digestion, and then detects the total nitrogen concentration via a reduction reaction. It is used for real-time monitoring of nitrogen content in wastewater and surface water, meeting discharge regulatory requirements.
Selection
When selecting, consider matching the measurement range with the actual concentration of the water body. Employ stable techniques such as chemiluminescence to ensure resistance to chloride ion interference. Prioritize modular designs for ease of maintenance, and ensure that the accompanying data acquisition system is compatible with existing platforms.

Terms

Instruments

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

With standard COD, total phosphorus, total nitrogen working procedures, support custom temperature and time; using new temperature control algorithm, heating uniform and fast, heating up to 165 ℃ only 12 minutes, temperature control accuracy +/- 1 ℃; one-button operation, with automatic alarm and transparent protective cover.

$ 767.00

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.

$ 2505.00

Adopting digestion Colorimetric integrated tube design, the detection process is safer and more convenient; the minimum display value is 0.001mg/L, and the Sensitivity is high; it supports a variety of detection paraMeter expansion to meet different water quality testing needs.

$ 4688.00

Digestion instrument and measuring instrument separation design to ensure measurement accuracy, using PID automatic temperature control technology, can save 30 standard Linear dispersion and 199 sets of measurement data, support room temperature to 180 ℃ wide range of temperature control.

$ 1742.00

Measurement range 0.000~ 1.000mg/L, including 100mL molybdate solution, 25 packs of ascorbic acid powder and 25 packs of potassium persulfate powder, suitable for water quality total phosphorus detection.

$ 164.00

Measurement range 0~ 500 ppm, accuracy +/- 3 ppm, support for CAL CheckTM Adjustment, suitable for a variety of water quality testing scenarios.

$ 215.00

Measurement range 0.00~ 3.50 ppm, accuracy +/- 0.03 ppm, using LED Illuminant and automatic shutdown function, easy and fast operation, suitable for a variety of water quality monitoring scenarios.

$ 215.00

Adopt photometric 90 ° scattering measurement method, equipped with automatic cleaning brush and bubble measurement cell, support automatic sewage discharge and cleaning interval setting, Measurement range 0.00-500 NTU, Repeatability ≤ 2%.

$ 2783.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column are used to remove trace ions efficiently, and intelligent microcomputer control realizes automatic operation and online water quality monitoring.

$ 2784.00

Colorimetric integrated tube design is adopted, sample digestion and detection share a tube, no need to transfer liquid; support more than 10 measurements and automatically remove abnormal values to average, error ≤ +/- 5%; can expand the detection of COD, ammonia nitrogen and other paraMeters.

$ 3268.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column, intelligent microcomputer control to achieve automatic operation and online water quality monitoring, effective removal of trace ions.

$ 3430.00

Simultaneous measurement of residual chlorine, chlorine dioxide, total chlorine and other five paraMeters, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and high Reliability integrated circuit to ensure long-term stable work.

$ 622.00

Adopt automatic nitrogen measurement distillation system, nitrogen measurement range 0.1-200 mgN, collection rate ≥ 99%, repeability rate < +/- 1% relative to Standard Deviation, semi-automatic working mode, distillation time 5-15 minutes, suitable for a variety of sample analysis.

$ 493.00

Articles

Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How can multi-parameter water quality analyzers avoid cross-contamination and improve data accuracy?
This article mainly discusses how to avoid cross-contamination in multi-parameter water quality testing to ensure data accuracy. Cross-contamination refers to the residue from a previous sample affecting the results of the next sample, which may lead to data deviation.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.