Temperature-Humidity Measuring Instrument

Temperature and humidity measuring instruments detect environmental temperature and humidity through sensors, converting physical quantities into electrical signals to display numerical values. They are used to monitor environmental conditions in places such as laboratories and warehouses, ensuring that material storage and experimental processes meet requirements.
Selection
When selecting, consider that the measurement range covers the usage scenarios, accuracy meets the requirements, response speed is appropriate for the application, calibration cycle complies with standards, protection rating suits the environment, and data logging functions are configured as needed.

Terms

Standards

Instruments

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.

$ 6691.00

Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.

$ 12579.00

With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.

$ 10401.00

The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.

$ 5110.00

Adopt microcomputer temperature and humidity controller, temperature uniformity +/- 1 ℃, humidity fluctuation +/- 5% RH, equipped with mirror stainless steel liner and observation window, support programmable control and multiple safety protection functions.

$ 4843.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 11482.00

Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.

$ 1953.00

Equipped with 7.0 inch Touchscreen controller, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., using French Taikang Compressor and multi-wing air supply circulation to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 6560.00

Using French Taikang fully enclosed Compressor, equipped with multi-wing air supply circulation system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2-3% R.H, improve test accuracy and efficiency.

$ 7754.00

With -40~ 150 ℃ Temperature range and 20~ 98% Humidity control, environmentally friendly refrigerant and double-decked airtight design, support multi-stage program editing and fast temperature Humidity control, easy to move and observe.

$ 8465.00

Temperature range -40~ 100 ℃, humidity control 35~ 95% RH, fluorine-free design, imported stainless steel liner, support multi-stage programming and remote communication, ensure uniform and stable insulation Humidity.

$ 5307.00

Articles

Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
Xenon lamp aging test chamber evaluates the long-term outdoor performance of resins.
Xenon lamp aging test chambers simulate environmental conditions such as sunlight, temperature, and humidity to accelerate the testing of the weather resistance of materials like resins in a laboratory setting.
Key Operation Points of Carton Burst Strength Tester
The carton bursting strength tester is used to measure the maximum force that paperboard can withstand before rupturing under uniform pressure, which is important for packaging quality control. Before operation, ensure that the instrument is stable and the calibration is valid. The samples should be cut according to standards and conditioned under standard temperature and humidity conditions.
Constant Temperature and Humidity Chamber Testing for Environmental Adaptability of Hot Melt Adhesive
This article introduces the method of testing the environmental adaptability of hot melt adhesive using a constant temperature and humidity chamber. The performance of hot melt adhesive is easily affected by temperature and humidity, and the purpose of the test is to evaluate its stability under different climatic conditions.
Constant Temperature and Humidity Chamber Testing for Ink Environmental Adaptability
This article introduces the method of testing the environmental adaptability of ink using a constant temperature and humidity chamber. Ink is prone to issues such as adhesion, discoloration, or reduced adhesion when exposed to changes in temperature and humidity.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Operation Specification for Circular Scratch Adhesion Tester
The circle method adhesion tester is used to evaluate the adhesion strength between coatings and substrates. Before operation, it is necessary to inspect the instrument, prepare samples, and control the ambient temperature and humidity. During testing, the sample should be secured, appropriate load and scratch spacing should be selected, and the stylus should be moved at a constant speed to create a circular scratch.
Analysis of the Influence of Temperature and Humidity on Paper Folding Endurance Testing
This article analyzes the impact of temperature and humidity on paper folding endurance testing. Paper folding endurance testing is typically conducted under standard temperature and humidity conditions, such as 23°C and 50% relative humidity.
Rapid prediction of coating chalking and gloss loss failure through UV aging tests.
This article introduces how UV aging tests can quickly predict the failure of paint chalking and loss of gloss. The test accelerates coating aging in the laboratory by simulating solar ultraviolet light, temperature, and humidity, while observing phenomena such as chalking and loss of gloss.
Key points for selecting a multi-factor comprehensive test chamber with integrated temperature, humidity, vibration, and altitude systems
The multi-factor comprehensive test chamber integrates four environmental stresses: temperature, humidity, vibration, and altitude (low pressure), used to simulate the reliability of products under complex environmental conditions.
UV aging test chambers are used for the aging evaluation of polymer materials.
The UV aging test chamber accelerates the aging process of polymer materials by simulating ultraviolet radiation from sunlight, combined with temperature and humidity control, to evaluate their durability.
How to Prepare Precise Film Layers Using a Laboratory Film Coating Machine
Precise film preparation can effectively eliminate human operational errors by rationally selecting applicators (wire rods or blades) that match the material's rheological properties and precisely controlling coating speed, environmental temperature and humidity, and substrate conditions.
Technical Selection and Application of Constant Temperature and Humidity Chambers
This article primarily discusses how to select and use a constant temperature and humidity chamber. It is mainly used to test the performance of materials and products under varying temperature and humidity conditions.