Online Dust Concentration Detector

The online dust concentration detector measures the content of suspended particulate matter in the air in real time using the principles of light scattering or beta-ray absorption. It is used for dust monitoring in places such as factory workshops and mines to control dust emissions and ensure the safety of the production environment.
Selection
When selecting, consider matching the measurement range with the on-site dust concentration, ensuring the explosion-proof rating meets environmental requirements, the probe's temperature and corrosion resistance, compatibility of the output signal with the existing control system, and the convenience of regular calibration and maintenance.

Terms

Standards

Instruments

The laser light scattering principle to achieve rapid measurement, detection sensitivity of 0.001mg/m ³, with online automatic mechanical Adjustment, built-in optical path self-cleaning system to avoid contamination of core components, support a variety of cutter selection.

$ 5399.00

Fast measurement using laser light scattering principle, with online automatic mechanical Adjustment, Measurement range 0.01-100 mg/m ³, built-in optical path self-cleaning system to avoid pollution, support a variety of cutters and sampling modes.

$ 5399.00

Explosion-proof enclosure design ensures stable operation in harsh environments, can simultaneously monitor multiple particle size dust concentration without changing the cutter, Measurement range 0.01-100 mg/m ³, built-in protective gas curtain to prevent Optical inspection system contamination.

$ 5043.00

With 0.001mg/m ³ detection sensitivity, support PM10, PM2.5 and other multi-particle size cutter selection, can automatically monitor and calculate the time weighted average, suitable for all-weather continuous operation.

$ 2252.00

Adopting stainless steel air duct and centrifugal fan, the wind speed can be adjusted, the dust concentration is 2.0~ 4.0kg/m ³, and it has the function of vertical circulation air flow and dust drying to ensure the accuracy and uniform dispersion of test data.

$ 10353.00

Using a 360 ° swirl/spin table and a 20W fluorescent lamp with a 60 ° irradiation angle, the effective detection area is 0.0625 square Meters, which can be accurately analyzed against the 0.05~ 5.0mm ² standard dust map.

$ 390.00

Adopt stainless steel air duct and centrifugal fan, dust concentration 2.0~ 4.0kg/m ³, liner size 1000 * 1500 * 1000mm, support vertical circulation air flow and dust drying function, ensure accurate and reliable test data.

$ 9465.00

Adopt stainless steel air duct and centrifugal fan, the wind speed is adjustable, the dust concentration is 2.0~ 4.0kg/m ³, support vertical circulation and dust drying, ensure test uniformity and data accuracy.

$ 8093.00

Using light scattering principle, detection sensitivity of 0.01mg/m ³, Measurement range 0.01-100 mg/m ³, with self-calibration system and air curtain Shielding function, 1 minute can directly read the mass concentration results, support timing sampling and over-standard alarm.

$ 1655.00

Support IP5X and IP6X Protection Rating test, liner size 1000 × 2000 × 1000mm, talc consumption 2kg/m ³, with automatic alternating control function of dust blower and dust vibration.

$ 17082.00

Pump suction sampling and dust design, equipped with dust Filter, Response Time T90 ≤ 20s, detection accuracy ≤ +/- 1%, suitable for harsh industrial environment.

$ 1038.00

Suitable for paper or Cardboard dust degree determination, in line with national standards, the effective area of the table is 0.0625 square Meters and can be 360 ° swirl/spin, and the standard dust map area is 0.05~ 5.0mm ².

$ 361.00

Using light scattering method, Sensitivity up to 0.001mg/m ³, Measurement range 0.001~ 10mg/m ³, with air curtain Shielding and self-cleaning function, to ensure that the Optical inspection system clean, support continuous monitoring and excessive alarm.

$ 1655.00

Imported Electrochemical sensor, Response Time T90 ≤ 20s, resolution 0.1ppm, dust-proof design equipped with dust Filter, adapt to a variety of harsh industrial environment.

$ 507.00

Adopt stainless steel air duct and vertical circulation air flow system, equipped with frequency converter to adjust the wind speed, dust concentration 2.0~ 4.0kg/m ³, built-in vibration and drying device to ensure the accuracy of test data.

$ 6334.00

Articles

How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Valley Beater in Pulp Laboratory Beating
The Valley beater is a device used in laboratories to simulate industrial beating processes. It modifies the morphology of pulp fibers through mechanical action, thereby influencing paper properties. During operation, parameters such as beating pressure, pulp consistency, and beating time must be controlled, with the beating degree serving as a quantitative measure of the effect.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Application of Salt Spray Test Chambers in Corrosion Resistance Testing of Automotive Components
The salt spray test chamber simulates a salty and humid environment to accelerate the testing of the corrosion resistance of automotive components. Its principle is based on electrochemical corrosion, allowing for the control of key parameters such as salt concentration and temperature.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.