The double Compressor and cascade refrigeration system are used to cool down quickly and have low noise; the overall foaming insulation of the Tank body reduces the loss of cooling capacity, the flow rate of the circulating pump is 10L/min to ensure Temperature uniformity, and the Temperature Fluctuation is only +/- 0.05 ℃.
With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.
Imported PT100 temperature sensor and double Compressor cascade refrigeration system, high refrigeration efficiency and low noise, Temperature Fluctuation +/- 0.05 ℃, Tank volume 30L, Circulating pump Flow rate 10L/min to ensure Temperature uniformity.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level protection and temperature runaway alarm functions.
The maintenance-free pressure pump is resistant to fiber metal particles, supports domestic circulation with sample Cup bracket and external circulation Viscometer jacket thermostatic, temperature control accuracy +/- 0.01 ℃ and low liquid level protection function.
The fully enclosed Compressor is used for refrigeration and overheating and overcurrent protection, the temperature control accuracy reaches 0.01 ° C, the pump flow rate is 10L/min, the stainless steel 304 structure is easy to clean, and the side plate can be disassembled for easy maintenance.
The non-heat centrifugal circulating pump is used to ensure uniform insulation field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices such as low water level anti-dry burning and Compressor overcurrent protection, optional temperature control and external Sensor to enhance application flexibility.
Imported stainless steel plate and circulating pump, Temperature Fluctuation ≤ +/- 0.5 ℃, Temperature range RT + 5~ 95 ℃, with anti-dry burning function, to ensure the safety and stability of the experiment.
The double Compressor refrigeration system is adopted to ensure rapid cooling, the overall foaming and heat insulation of the Tank body reduces the loss of cooling capacity, the flow rate of the circulating pump is 8L/min to ensure the uniformity of the liquid, and the Temperature Fluctuation is only +/- 0.05 ℃.
Adopt non-heat centrifugal circulating pump to avoid self-heating effect, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection including low water level anti-dry burning and Compressor over-current protection to ensure the safety and stability of the experiment.
Imported Pt100 temperature sensor and dual Compressor refrigeration system, rapid cooling and low noise, Temperature Fluctuation +/- 0.05 ℃, 6L volume Tank with 8L/min circulating pump to ensure Temperature uniformity.
Temperature range -50~ 100 ℃, temperature resolution of 0.01 ℃, fully enclosed Compressor refrigeration and 304 stainless steel liner, equipped with 10L/min circulating pump and removable side panels for easy cleaning and maintenance.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with six safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.
With -20 ℃~ 100 ℃ wide Temperature range, Temperature Fluctuation control within +/- 1 ℃, working volume 5L, equipped with adjustable circulating pump Flow rate 0~ 6L, using alcohol refrigeration medium to ensure low temperature Stability.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, temperature control accuracy +/- 0.5 ℃, with low water level protection, temperature runaway alarm and other multiple safety functions to ensure the stable operation of the experiment.