Thermal Indicator Strip

The temperature indicator strip displays temperature through the color change of thermosensitive materials when heated. The principle is based on physical or chemical changes in the material at different temperatures, leading to a change in color. Its function is to visually indicate the surface temperature of objects. It is applied in monitoring industrial processes such as welding and heat treatment, as well as in safety temperature detection for electronic components and mechanical equipment.
Selection
When selecting a temperature strip, ensure it matches the temperature range of the object being measured, taking into account response time and clarity of color change. Pay attention to the adhesive properties of the substrate to ensure compatibility with the surface material, as well as environmental durability such as water resistance or chemical resistance. Choose between disposable or reusable types based on single-use or reversible needs, and refer to the manufacturer's calibration data for guidance.

Terms

Standards

Instruments

The device can precisely control the film thickness of the ink layer of the color strip, and the ink injection amount is 0.0012g, which is used for ink contrast and color concentration detection.

$ 173.00

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

The mechanical compression spring device is not easy to damage, the accuracy is up to 0.5HW, the film thickness 0.4-6 mm workpiece can be detected, and various Hardness values such as Brinell Rockwell can be obtained through the conversion table.

$ 477.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

The transient planar heat source method is used, the test time is not more than 160 seconds, the Sensitivity is 0.00001, and the thermal conductivity of 0.0001 to 50W/(m * K) can be measured. It supports a variety of morphological samples and meets international standards.

$ 12983.00

Using oil Bath heating medium, Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.5 ℃, equipped with sample clamping grid to ensure temperature stability, suitable for various film thermal cissing rate tests.

$ 1510.00

The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.

$ 16840.00

Temperature resolution of 0.1 ℃ and heating rate of 0.1~ 20 ℃/min can be adjusted continuously. It supports hot stage method and visual measurement, and is suitable for the study of thermal characteristics of trace samples.

$ 5971.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted without complex installation and is suitable for temperature monitoring of a variety of electrical equipment.

$ 89.00

Temperature resolution is up to 0.1 ℃, heating rate is adjustable from 0.1 ℃ to 20 ℃/min, hot stage method and visual measurement are supported, which is suitable for the study of thermal characteristics of trace samples.

$ 4600.00

Irreversible discoloration design to ensure permanent preservation of temperature records, 85 ° C accurate temperature measurement point with 2x2cm circular patch, Pressure sensitive adhesive layer to achieve firm paste and its own protective film to enhance durability

$ 89.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted and used without complicated operation, and is suitable for temperature monitoring of various electrical equipment.

$ 91.00

The minimum measurable inner diaMeter is 10mm, the maximum sample thickness is 6mm, and the imported special steel crimp and high-strength pointer components are used. It has good Stability and portability and supports Hardness value conversion.

$ 1017.00

Articles

Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Transverse Burst Strength Tester for the Evaluation of Impact Resistance of Corrugated Cardboard
This article explains how a lateral bursting strength tester is used to evaluate the impact resistance of corrugated cardboard. It measures the energy absorbed by the cardboard at the point of rupture using the pendulum impact principle, requiring the preparation of specimens according to standards and the control of environmental conditions during testing.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Rubber abrasion tester measures tire wear resistance.
The rubber abrasion tester evaluates wear resistance by simulating the friction between tires and road surfaces. It uses a grinding wheel to rub against rubber specimens under set conditions, measuring mass loss and converting it to volume loss to assess material performance.
Xenon lamp aging test chamber for testing film weather resistance.
This article introduces how a xenon lamp weathering test chamber tests the weatherability of films. It uses a xenon lamp to simulate sunlight and controls conditions such as temperature and humidity to accelerate the aging process of the film, thereby evaluating its performance changes in outdoor environments.
Reflectometer Selection: Light Source Geometric Conditions and Contrast Ratio Testing
This article primarily discusses that when selecting a reflectometer, the geometric conditions of the light source are crucial, as they directly affect the accuracy of the measurement results.
Considerations for Channel Count and Temperature Endurance in Furnace Temperature Tracker Selection
When selecting a furnace temperature tracker, the main considerations are the number of channels and the temperature resistance duration. The number of channels is determined based on the quantity of temperature measurement points plus spare channels. Too few channels may lead to data loss, while too many channels can increase costs.
Temperature Paper Selection: Temperature Gradation and Response Speed Evaluation
This article mainly discusses how to choose the right temperature measurement paper. It points out that two key parameters should be considered during selection: the temperature steps and the response speed.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.