Air humidity Thermometer

The air humidity thermometer measures ambient temperature through a temperature-sensitive element and detects the moisture content in the air using a humidity-sensitive element, displaying temperature and humidity values. It is used to monitor environmental conditions in places such as laboratories and warehouses to ensure stable material storage and experimental conditions.
Selection
When selecting, consider that the measurement range should cover the temperature and humidity intervals of the operating environment, the accuracy should meet practical needs, the response speed should match the monitoring frequency, the probe material should be suitable for environmental characteristics, the calibration cycle should comply with usage standards, and the data output method should be compatible with the recording system.

Terms

Standards

Instruments

Dual thermoMeter design can simultaneously measure wet-bulb temperature, equipped with special conversion ratio calculation tool, Temperature Measurement range covering -5 to 50 ℃, Humidity Measurement range 10-100% RH.

$ 391.00

Built-in Air Temperature Humidity Sensor and K-Connector, with armored cable and magnetic surface temperature sensor to prevent accidental detachment, supports a variety of optional Probe conversions.

$ 830.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.

$ 10401.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 11482.00

Mirror stainless steel liner and high-efficiency air circulation system, Temperature range -5~ 80 ℃, Humidity deviation +/- 3% R.H., support 99 cycle programs to ensure experimental Stability and uniformity.

$ 3402.00

Equipped with 7.0 inch Touchscreen controller, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., using French Taikang Compressor and multi-wing air supply circulation to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 6560.00

Using French Taikang fully enclosed Compressor, equipped with multi-wing air supply circulation system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2-3% R.H, improve test accuracy and efficiency.

$ 7754.00

Multi-wing air supply cycle to ensure uniform distribution of temperature and humidity, support 120 sets of program control and data export functions, Temperature Fluctuation +/- 0.5 ℃, humidity deviation +/- 2% R.H., with complete fault diagnosis and safety protection mechanism.

$ 5931.00

Adopt 7-inch touch controller to support 120 program settings, equipped with multi-wing air supply system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation +/- 0.5 ℃, humidity deviation +/- 2% R.H to ensure test accuracy.

$ 5576.00

With -60~ 150 ℃ wide temperature range and 30~ 98% RH humidity control, multi-wing air supply cycle to ensure uniform temperature and humidity, 7.0 inch large screen programmable controller supports 100 sets of programs to improve test efficiency and accuracy.

$ 8142.00

Using French Taikang Compressor to ensure stable cooling, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure the uniformity of the test area.

$ 8142.00

Temperature uniformity is ensured by centrifugal turbine forced air supply, temperature distribution accuracy +/- 1 ℃, Humidity Control Range 45% -90% RH, support 30-stage program control and power failure protection function.

$ 2203.00

Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2-3% R.H, with 100 sets of program capacity and RS-232/485 communication function.

$ 12402.00

Articles

Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
Sheffield Smoothness Tester for Analyzing Paper Printing Surface
This article introduces how the Sheffield smoothness tester analyzes the printing surface of paper. The instrument quantifies paper smoothness by measuring the air leakage time, with a longer time indicating a smoother surface.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
What is the difference between the Bendtsen method and the Gurley method for measuring paper air permeability using an air permeability tester?
The air permeability of paper is a key indicator for evaluating its structural compactness and suitability, especially crucial in fields such as packaging, filtration, and specialty papers. The Bendtsen and Gurley methods are two classic and widely used techniques for determining paper permeability.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.