Ammonia sensor

Ammonia sensors detect changes in ammonia concentration in the air through electrochemical or semiconductor principles, converting chemical signals into electrical signals for output. They are used in scenarios such as environmental monitoring, industrial safety, and agricultural farming to reflect real-time ammonia leakage or accumulation.
Selection
When selecting, consider matching the detection range with the on-site ammonia concentration, ensuring the response speed meets actual requirements, and verifying that the operating temperature and humidity conditions are suitable. Pay attention to the sensor lifespan and calibration cycle, ensure the output signal is compatible with existing equipment, and evaluate the explosion-proof rating and installation method.

Terms

Standards

Instruments

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Using pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, detection accuracy ≤ +/- 3%, support 1-4 Sensor expansion, Protection Rating IP65 for harsh environments.

$ 527.00

Electrochemical sensor for rapid Response, detection accuracy of +/- 2% F. S, with Intrinsic Safety (IS) design and a variety of signal output interfaces, support remote monitoring and data transmission, adapt to -30~ 50 ℃ working environment.

$ 888.00

The filling liquid capacity of 30mL, the use of PTFE bottles, Dimension 65mm high × 30mm diaMeter, weight of only 20g, suitable for the maintenance of Ammonia Gas sensing electRode.

$ 135.00

Electrochemical sensor for rapid Response, detection accuracy of +/- 2% F. S, with RS485 and 4-20mA output, explosion-proof design for hazardous environments, support for remote monitoring and multi-system compatibility.

$ 630.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With Intrinsic Safety (IS) design, support RS485 and 4-20mA dual output, equipped with 2.5 inch color screen display real-time concentration, Temperature Humidity paraMeters.

$ 630.00

ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.

$ 135.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring, automatic zero tracking to prevent drift.

$ 453.00

Imported Electrochemical sensor, Response Time less than 10 seconds, detection accuracy +/- 2% F.S, with automatic Zero tracking and temperature compensation function, explosion-proof design supports a variety of signal output, suitable for harsh industrial environment.

$ 453.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With intrinsically safe circuit design and IP66 Protection Rating, support RS485 and 4-20mA signal output, suitable for long-term stable monitoring of hazardous environments.

$ 888.00

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

Electrochemical sensor, Response Time ≤ 20 seconds, range 0-100ppm, resolution 0.1ppm, waterproof, dustproof and explosion-proof design, support sound and light vibration triple alarm and Sensor fault self-check function.

$ 202.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Dart impact tester measures the toughness of packaging film.
The dart impact test evaluates the material's resistance to damage under dynamic impact, i.e., its toughness, by allowing a dart to fall freely and strike the packaging film. During the test, different impact energies are simulated by adjusting the weight of the dart or the drop height, and sensors are used to detect whether the film ruptures.
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
In the selection of illuminance meters, sensor type and measurement range are key considerations.
This article introduces the key points for selecting sensor types and measurement ranges when choosing an illuminometer.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Key points for operating a hot melt adhesive softening point tester
The hot melt adhesive softening point tester is used to measure the softening temperature of materials when heated, which is important for quality control. Before operation, ensure that the ambient temperature is around 23 degrees, place the instrument level, check if the heating oil is clean, and calibrate the sensor.
Comparison of Humidity Control Methods in Constant Temperature and Humidity Test Chambers: Wet and Dry Bulb Method vs. Electronic Sensor Method
This article will explain the principles, advantages, and disadvantages of these two methods to help you make a more informed decision when selecting equipment.