Laboratory Ammonia Nitrogen Detection Instrument

The laboratory ammonia nitrogen detector adopts the Nessler reagent spectrophotometric method. Ammonia nitrogen in the water sample reacts with the reagent to form a yellow-brown complex, and the ammonia nitrogen concentration is calculated by measuring the absorbance. It is used to determine the ammonia nitrogen content in water bodies and industrial wastewater, thereby monitoring the degree of water pollution.
Selection
When selecting, consider that the measurement range should cover the sample concentration, the detection limit must meet standard requirements, and the operation steps should be simple and fast. The instrument should have calibration functions and data storage capabilities. Choose a manual or automatic model based on the sample volume, and confirm the stable supply of supporting reagents.

Terms

Standards

Instruments

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Optical inspection system using imported cold Illuminant and narrow band interference, Optical inspection stability is less than 0.002A/20min, digestion temperature accuracy +/- 0.5 ℃, support COD and ammonia nitrogen dual paraMeter measurement, can save multiple standard Linear dispersion and data.

$ 1548.00

Colorimetric digestion integrated tube operation, no liquid transfer; water samples for more than 10 measurements to take the average value; ammonia nitrogen detection limit of 0.01mg/L, measurement error ≤ +/- 5%, data storage 30,000.

$ 1493.00

Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.

$ 212.00

Measurement range 0.00~ 9.99 ppm, accuracy +/- 0.05 ppm, LED Illuminant 470 nm, automatic shutdown function, compact and portable design.

$ 217.00

Measurement range 0.02~ 25mg/L, resolution 0.01mg/L, Repeatability ≤ 3%, Linearity +/- 3% FS, eliminating human error.

$ 262.00

Adopting digestion Colorimetric integrated tube design, the detection process is safer and more convenient; the minimum display value is 0.001mg/L, and the Sensitivity is high; it supports a variety of detection paraMeter expansion to meet different water quality testing needs.

$ 4688.00

Imported cold light source technology life of 100,000 hours, support 0.001mg/L high Sensitivity detection, with digestion Colorimetric integrated tube design to achieve safe and fast measurement, can store 4000 sets of data and support multi-mode power supply.

$ 2946.00

The imported cold light source has a lifespan of 100,000 hours, a detection limit of 0.05mg/L, supports continuous measurement and standard Measurement mode, and has 4000 sets of data storage and various transmission interfaces.

$ 816.00

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

Adopt digestion Colorimetric integrated tube design, detection is safer and more convenient; Minimum display value of 0.001mg/L, Sensitivity is high; Support standard measurement and continuous measurement mode, built-in 4000 sets of data storage, to meet different detection needs.

$ 3268.00

Measurement range covers 0.05-1000 mg/L, glass sensitive film design, temperature range 5-45 ℃, equipped with Q9 connector to ensure stable detection of ammonia nitrogen content.

$ 504.00

Imported cold Illuminant and narrow band interference Optical inspection system, Optical inspection stability is less than 0.002A/20min, repeability ≤ 2%, can store 10 standard Linear dispersion and 500 data, support USB data upload and printing function.

$ 677.00