Measurement range 0~ 199.5GU, accuracy 0.5GU, professional optical path design to ensure stable and reliable data, built-in rechargeable battery can work for more than 48 hours.
The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily calibrating needs.
General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.
The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily calibrating needs.
Using open liquid junction design, suitable for general contaminated samples, Measurement range 0-14pH, Temperature range 0-80 ℃, PEEK shell material, long life reference system.
Single angle 60 ° measurement, Stability 0.4GU, Repeatability 0.5GU, Automatic calibration without manual operation, can store 254 sets of data, lightweight and portable design.
Support 20 °/60 °/85 ° three-angle measurement, Measurement range 0~ 200GU, Repeatability +/- 0.5GU, Stability +/- 0.4GU, can store 254 sets of data and have Automatic calibration function.
Dual angle measurement 20 ° and 60 °, Stability less than +/- 0.4GU/30Min, Repeatability 0.5GU, can store 254 sets of data, portable and lightweight design, Automatic calibration without manual adjustment.
With 60 ° Measurement Angles and 9 * 15mm Measuring Area, the repeatability is up to +/- 1GU, with automatic check and correction standard board function and 30-second automatic shutdown design, which meets the requirements of JJG696 secondary working Glossmeter.
Impact energy 11N, Impact device mass 75g, suitable for general-purpose part measurement, can be measured with a minimum thickness of 3mm, and a minimum diaMeter of 0.35mm.
Glass testtube with bubble well structure, length 100mm, diaMeter 27mm, capacity 8 square centiMeters, suitable for a variety of PolariMeter types.
Glass shell structure with bubble well design, testtube length 200mm, diaMeter 27mm, capacity of 15 square centiMeters, to ensure the accuracy of Optical inspection measurement and ease of operation.
Operating temperature range 0-70 ° C, temperature sensor, multi-pin connector support, maximum pressure 0.2 bar.
PD array Detector to achieve CIE V (lambda) 2 degree Visual Response, measurement aperture Φ 15mm, support open sample Chamber vertical horizontal test, dynamic monitoring of Illuminant and environment changes to ensure reliable data.
The weight is only 0.23kg and the size is small, the built-in sensor accuracy reaches 0.5 level, supports 5 unit conversion and real-time tracking modes, can set the upper and lower limit alarm and peak holding time, and the lithium battery lasts about 25 hours.