Metal Rockwell Hardness Tester

The metal Webster hardness tester measures hardness by pressing a conical indenter into the metal surface under a fixed test force and converting the indentation depth into a hardness value. It is used for rapid on-site hardness testing of soft metals such as aluminum and copper alloys, and is suitable for quality control of profiles and pipes.

Instruments

Support six kinds of Hardness standard conversion, equipped with high luminance LED backlight, metal shell anti-interference, standby time up to 100 hours, can store 600 sets of data, adapt to various harsh environments.

$ 425.00

High Accuracy Stepping Control system, support HR, HB, HV conversion scale, large test space, Built-in Printer and RS-232 interface, suitable for a variety of hardness of materials.

$ 3139.00

With three Adjustments, it can simultaneously measure Richter, Brinell, Rockwell and other Hardness values, indication Repeatability 6HLD, support 360 ° measurement direction, standard D-type Impact device and optional Miscellaneous type, anti-vibration Impact electromagnetic interference.

$ 348.00

D type High Accuracy Impact device, Measurement accuracy is stable, can measure 7 kinds of Hardness values and automatically switch, Data storage up to 500 groups, with indication software Adjustment, fully sealed metal shell has excellent anti-vibration and electromagnetic interference ability.

$ 512.00

Using D type High Accuracy Impact device, Measurement range 30~ 110HS, can detect cast steel roll, forged steel roll and cast iron roll three kinds of hardness of materials, with anti-Impact and anti-electromagnetic interference ability, support 7 kinds of Hardness standard automatic conversion.

$ 554.00

The integrated structure is compact and portable, and the dual-coil technology is used to ensure good Repeatability and Measurement accuracy. The built-in Direction Sensor automatically compensates for errors, and supports a variety of Hardness standard conversions.

$ 180.00

According to the Richter Hardness Measurement principle, it can perform High Accuracy detection on all metal materials, support a variety of Hardness standard conversion, Measurement range HLD 170-960, can store 600 sets of data, equipped with true color screen and USB interface.

$ 296.00

The device adopts D-type Impact device, supports 360 ° measurement, can display a variety of Hardness standards, has 600 sets of Data storage capacity, is small in size and weighs only 0.2kg, and has a standby time of 100 hours. It is suitable for small spaces and field environments.

$ 192.00

The use of New material has a long life, stable fullness point and correction point, and can measure 0.6-8 mm thickness materials. Hardness value can be converted into Vickers, Rockwell and other standards.

$ 725.00

Adopt D-type Impact device and optional Miscellaneous six Impact devices, automatic identification and replacement without calibrating; can store 600 sets of measurement data, support seven Hardness standards automatic conversion, Measurement range covers 30~ 110HS to 80~ 976HV.

$ 340.00

The use of New material has a long life, stable fullness point and correction point, Hardness value can be converted into Vickers Rockwell Brinell, the range is 0-20HW, and the accuracy is 0.5HW, which is suitable for workpieces with a thickness of 0.6-13 mm.

$ 725.00

Impact energy 11mJ, Impact device mass 50g, ball head diaMeter 3mm, Hardness measurement hole or cylinder, suitable for a variety of metal hardness of materials testing.

$ 162.00

The mechanical compression spring device is not easy to damage, the accuracy is up to 0.5HW, the film thickness 0.4-6 mm workpiece can be detected, and various Hardness values such as Brinell Rockwell can be obtained through the conversion table.

$ 477.00

Impact energy 11mJ, ball head diaMeter 3mm tungsten carbide material, can measure a variety of metal hardness of materials, Che diaMeter minimum 0.35mm, suitable for conventional Hardness testing needs.

$ 154.00

The Che design can be operated with one hand, the test range is equivalent to Brinell 25-135HB, and the measurement can be completed on one side without support. It has the function of extreme value retention and average calculation of 29 sets of data.

$ 735.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.