Vertical Combustion Test Chamber

The vertical flame test chamber is used to determine the combustion performance of materials in the vertical direction. Its principle involves vertically suspending the sample, igniting the lower end with a standard flame, and recording data such as burning time and damaged length. This equipment is used to evaluate the flame-retardant properties of materials and is suitable for combustion safety testing in industries such as plastics and textiles.
Selection
When selecting a vertical flame test chamber, consider the testing standards (such as UL94, GB/T5455) and ensure that parameters like flame height and application time are adjustable. The chamber material should be corrosion-resistant and equipped with exhaust and safety protection features. Determine the inner cavity size based on the sample dimensions and testing volume, and verify the accuracy of the temperature control and data recording systems.

Terms

Standards

Instruments

Equipment supports vertical and horizontal combustion test, can set combustion and extinguishing time and repeability times, automatic stop test, Internal dimensions 305 * 355 * 610mm, suitable for a variety of organic materials.

$ 691.00

Equipped with combustible gas concentration detection and alarm system, automatically cut off the gas and start the exhaust; Test space ≥ 0.5m ³, flame height 20-175mm adjustable; support a variety of combustion angle adjustment to ensure test accuracy.

$ 1445.00

Gas detection alarm device and automatic exhaust system, flame time 0-999.9s adjustable, flame height 20-175mm adjustable, support a variety of combustion angle adjustment to ensure safe and accurate testing.

$ 1848.00

Test space ≥ 0.5m ³, flame application time 0~ 99min99s can be set, combustion angle 20 °, 45 °, 90 ° adjustable, flame height 20mm to 175mm adjustable, motor drive automatic alignment spline.

$ 1174.00

1KW standard blowtorch, flame height 170-190mm, support 0.1-999 seconds holding time setting, with automatic timing and high voltage ignition function, suitable for flame retardant performance testing of various cable materials.

$ 1219.00

Using Bunsen burner combustion device, nozzle inner diaMeter 9.5mm, automatic ignition control, flame application time accuracy of +/- 0.1 seconds, can simulate open flame environment to evaluate battery flame resistance and leakage risk.

$ 1776.00

Stainless steel combustion box flue gas and corrosion resistance, Control system Degree of automation, flame time 0-99 minutes and 99 seconds adjustable, flame height 20-100mm adjustable, automatic recording of the test process.

$ 832.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.

$ 832.00

Catalytic combustion Sensor, adjustable detection accuracy, temperature compensation and automatic zero correction function, support 4~ 20mA output and RS485 digital output, suitable for hazardous areas.

$ 143.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with infrared remote control debugging and 4~ 20mA output, support alarm record query and automatic temperature compensation, suitable for hazardous environment.

$ 152.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with automatic zero correction and temperature compensation function, support 4~ 20mA and RS485 output, infrared remote control safety adjustment.

$ 122.00

Using catalytic combustion Sensor, range 0~ 100% LEL, with automatic zero correction and temperature compensation function, support infrared remote control adjustment and 4~ 20mA standard output, suitable for dangerous places 1 and 2 zones.

$ 135.00

Using catalytic combustion detection principle, the range covers 0-100% LEL, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote monitoring and linkage control.

$ 190.00

Articles

How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Pull-off Adhesion Tester for Quantitative Measurement of Varnish Adhesion.
The pull-off adhesion tester quantitatively measures the adhesion strength between a varnish coating and the substrate by vertically pulling off a test column. It is essential to ensure proper substrate preparation, complete curing of the coating, and the use of a suitable adhesive during testing.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Adhesion Tester Pull-Off Method for Determining Adhesion Strength of Varnish
This article introduces the test method for measuring the adhesion strength of varnish using the pull-off method. It involves adhering test cylinders to the coating and substrate with adhesive, then vertically pulling them apart with an instrument to record the maximum pulling force and calculate the adhesion strength.
Internal Bond Strength Scott Tester for evaluating interlayer bonding force of paper.
This article introduces the method of evaluating the interlayer bonding strength of paper using a Scott tester. The interlayer bonding strength affects the printing and mechanical properties of paper. During testing, the instrument peels the paper vertically through an adhesive test head, records the energy required for separation, and calculates the internal bond strength.
Application of Paperboard Burst Strength Tester in Packaging Materials
The paperboard bursting strength tester is a detection device used to measure the ability of packaging materials such as paperboard to resist rupture under vertical pressure. During the test, the sample is clamped between annular clamps, and increasing pressure is applied via hydraulic or pneumatic means until rupture occurs. The maximum pressure value is recorded as the bursting strength.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Standard Operating Procedure for Packaging Drop Tester
The packaging drop tester is used to evaluate the impact resistance of transport packages during vertical drops. Before operation, it is necessary to check the safety of the equipment, calibrate the drop height, and prepare the test specimens according to standards.
Sand Falling Test Apparatus for Measuring the Wear Resistance of Powder Coatings
The sand falling test instrument determines the wear resistance of powder coatings by simulating sand particle impact. During the test, abrasive material falls vertically from a specified height, continuously scouring the coating until the substrate is exposed. The wear resistance is evaluated based on the mass of abrasive material consumed.
Pull-off adhesion tester quantitatively measures bond strength.
The pull-off adhesion tester measures the bonding strength between coatings, linings, and substrates by applying a vertical tensile force.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.