Temperature range -20~ 150 ℃, studio volume 250L, using multi-layer conductive film tempered hollow Glass observation window and upper air supply and lower air return mode to ensure Temperature uniformity and test accuracy.
Category : High Low Temperature Test Chamber
Brand : hzaoc
SKU : NB038446
Service :The delivery and service By NBCLab.Com
HZAOC GDJW-250A low/high temperature test Chamber is suitable for the adaptability test of electrical, electronic products, components, parts and materials in high and low temperature environment storage, transportation and use, as well as temperature gradual change test. Stress screening test can also be carried out on electronic components.
1. The box adopts the overall structure, the inner side is 1.0mm SUS304B stainless steel plate, the outer side is 1.0mm Cold rolled steel plate sprayed, and the thermal insulation material is ultra-fine Glass thermal insulation cotton 2. Door sealing with double-decked silicone rubber sealing material 3. The observation window is multi-layer conductive film tempered hollow Glass, size 200 × 300mm, built-in special heating wire frost-proof, with lighting 4. The side of the box is equipped with φ 50mm test hole, and the stopper material is silicone rubber low foam 5. The heating device adopts porcelain frame nickel-chromium wire electric heating device, which has small thermal inertness and long service life 6. Low temperature refrigeration adopts French "Taikang" fully enclosed Compressor unit, using R404A environmentally friendly refrigerant 7. High Accuracy Digital Temperature Controller for Accurate and Stable Control 8. Control system with Safety protection measures, including phase loss protection, phase sequence error protection, over temperature protection, etc 9. Equipped with independent over-temperature protector and interlock device
The test Chamber achieves temperature control through the heating system and the refrigeration system. The heating device adopts a porcelain frame nickel-chrome wire electric heating device, which is controlled by the instrument outputting a controllable pulse duty cycle PID signal and controlled by a solid state relay. The low temperature refrigeration adopts a French "Taikang" fully enclosed Compressor unit with imported brand refrigeration components. The temperature sensor is placed in a trend, and the air is circulated by the upper air supply and lower air return mode to ensure Temperature uniformity.
Electrical, electronic products, components, parts and materials of high and low temperature environmental adaptability test, temperature gradual change test, stress screening test
GB/T2423.1-2001、GB/T2423.2-2001、GB/T10592-2008、GB/T10589-1989、GB/T11158-1989、IEC68-2-1、IEC68-2-2
1. Turn on the power supply and check whether the Power supply voltage meets the requirements of AC380 (+/- 10%) V/50HZ three-phase five-wire system 2. Check the water source and ensure that deionized water or purified water is used 3. Set the test parameters through the operation panel, including Temperature range, heating rate, cooling rate, timing time, etc 4. Start the circulating fan and confirm normal operation 5. Start the heating or cooling system for testing 6. Monitor the test process through the observation window 7. After the test, shut down the systems in sequence
• Ambient Temperature should be kept within 5~ 28 ℃ • Environmental humidity should be ≤ 85% R.H. • Must use deionized water or purified water as a source of water • When the circulating fan is not started or overloaded, the refrigeration unit and heating system cannot be started • When the equipment is running, pay attention to the operation of the high voltage meter monitoring system • In the event of abnormal conditions such as overtemperature and power failure, the protection system will automatically cut off the power supply • Regularly check the status of sealing materials and insulation materials • Disconnect the power supply during maintenance to ensure safety
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.