Gold-nickel thickness Tester

The gold-nickel thickness tester measures the thickness of coatings using X-ray fluorescence, calculating based on the relationship between the intensity of characteristic X-rays of elements and thickness. It is used to detect the thickness of gold-nickel coatings on surfaces such as circuit boards and connectors, ensuring coating uniformity.
Selection
When selecting, consider that the measurement range covers the thickness of the product coating, the accuracy meets process requirements, and it is equipped with gold-nickel standard pieces for calibration. Choose fixtures based on the sample shape, review the instrument's stability report, and confirm compliance with industry testing standards.

Terms

Standards

Instruments

The large sink design is used to reduce buoyancy errors, and Brazilian fire gold with coating thickness > 30μm can be tested with a density accuracy of 0.0001g/cm ³, which supports the analysis of the mixing ratio of various precious metals.

$ 503.00

Measurement range 0~ 300μm, resolution up to 0.01μm, support multi-layer nickel potential difference analysis, test size optional Φ 2.4mm to Φ 0.8mm.

$ 2978.00

The large sink design is used to reduce buoyancy error, the density accuracy is 0.001g/cm ³, and the Brazilian fire gold with coating thickness > 30μm can be tested, and the mixing ratio of various precious metals can be measured.

$ 462.00

Using Spectrophotometric method, spectra-trophotometry to detect nickel concentration, detection limit of 0.1mg/L, equipped with imported cold light source life of 100,000 hours, support a variety of Measurement mode and wireless data transmission function.

$ 816.00

Using Spectrophotometric method, specs-trophotometry to detect nickel content, Measurement range 0.00-7 g/L, accuracy +/- 0.10g/L, equipped with LED@575nm Illuminant, easy to operate without complex pretreatment, suitable for rapid batch detection needs.

$ 215.00

Measurement range 0.03~ 50μm, resolution 0.01μm, support single-layer, multi-layer and alloy platings testing, built-in thermal printer to automatically output statistical reports, suitable for wire and columnar workpieces.

$ 1364.00

Colorimetric analysis is achieved using a pre-measurement design, which reacts with nickel to form a blue complex. Measurement range covers 0.00 to 7.00 g/L, and it is suitable for a variety of Photometer instruments.

$ 540.00

Density accuracy of 0.001g/cm ³, maximum weighing 310g, built-in density reference can be customized settings, support solid liquid powder and Water Absorbency sample testing, equipped with level indicator and overload alarm function.

$ 525.00

Measurement accuracy of 0.001g/cm ³, support temperature compensation and mixed specific gravity measurement, can cycle display K number and purity%, with over-limit prompt function, operation only needs two steps.

$ 338.00

Measurement range 5-600g, density accuracy 0.001g/cm ³, with temperature compensation and mixing ratio measurement function, without leaving traces after testing.

$ 378.00

Measurement principle of hanging water method, density accuracy of 0.001g/cm ³, support one key zero and temperature compensation function, can cycle display K number and purity percentage, and have mixed specific gravity determination and over-limit prompt function.

$ 441.00

Measurement range 0.03-50 um, resolution 0.01um, supports multi-layer platings and alloy platings measurement, with custom hotkeys and LCD display, easy to operate without adjusting Sensitivity.

$ 1235.00

Measurement range 3000g accuracy 0.01g, support solid particle floating body and other samples, with water temperature compensation and automatic Zero tracking function, the internal sink space up to 24 * 17 * 12cm.

$ 751.00

Using monochrome cold Illuminant and narrow band filter system, Optical inspection stability, high accuracy; measurement range 0.02~ 1.00mg/L, Indication Error ≤ +/- 5%; large screen LCD Chinese display, data can be stored for a long time, the host corrosion resistance is good.

$ 499.00

Measurement range 000-1.000 mg/L, accuracy +/- 0.010mg/L, LED Illuminant and unique reference Detector ensure Stability, support GLP data recording and automatic storage, waterproof design for a variety of environments.

$ 632.00

Articles

Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Application of Automatic Film Coating Machine in Waterproof Coating Finishing of Textiles
Automatic film coating machines are used for waterproof coating finishing on textiles, enabling precise control of coating thickness, improving uniformity and production efficiency.
Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
Application of Wet Film Wheel Gauge in Continuous Measurement of Wet Film Thickness for Large-Area Coatings
The wet film wheel gauge is a mechanical tool used to measure the thickness of wet coatings, operating based on the geometric relationship of three coaxial disks (two parallel outer wheels on the sides and an eccentric inner wheel in the middle).
Operating specifications for on-site measurement of coating wet film thickness using wet film combs
This article introduces the operational standards for on-site measurement of coating wet film thickness using a wet film comb gauge. First, it explains the measurement principle of the wet film comb gauge, which involves estimating the thickness by observing the extent to which the teeth of the gauge are coated with the paint.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of wet film thickness gauge range and accuracy requirements for comb teeth spacing.
When selecting a wet film thickness gauges, the key considerations are the measurement range and the accuracy of the comb teeth spacing. The range should cover the coating thickness with a slight margin to avoid being too small for measurement or too large, which could reduce resolution.
Preparation of composite films by coating mechanism for electrical performance experimental characterization
This article introduces the method of preparing composite films using a film coating machine and testing their electrical properties. The film coating machine evenly spreads the slurry with a blade, controlling thickness and uniformity. The preparation process includes raw material preparation, substrate treatment, coating, and curing.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
The coating machine applies an anti-reflection coating on the surface of optical lenses.
A coating machine is a precision device used for depositing anti-reflection coatings on the surface of optical lenses. Based on the principle of light interference, it forms a thin film of specific thickness on the lens surface through physical or chemical methods to reduce light reflection and enhance light transmission performance.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Multilayer functional films are constructed by layer-by-layer coating using a coating machine.
This article introduces a method for preparing multilayer functional films using a coating mechanism. By sequentially coating different materials layer by layer, it enables precise control over the thickness and structure of each layer, thereby adjusting the optical, electrical, and other properties of the films.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.