Color-changing temperature indicator strip

Color-changing temperature indicator strips display the surface temperature of objects by using thermosensitive materials that change color at specific temperatures. Their function is to visually indicate temperature conditions during heating processes, commonly used for simple temperature monitoring in industrial equipment, electronic components, and heat treatment processes.
Selection
When selecting, it is necessary to match the target temperature with the color-changing temperature point of the temperature-indicating strip, taking into account the substrate adhesion and environmental tolerance. Pay attention to the differences in color-changing reversibility: choose irreversible types for single-use applications and reversible types for repeated monitoring. The size of the observation window should be adapted to the detection location.

Terms

Standards

Instruments

The device can precisely control the film thickness of the ink layer of the color strip, and the ink injection amount is 0.0012g, which is used for ink contrast and color concentration detection.

$ 173.00

Measuring temperature 90 ℃ and the error is only +/- 1 ℃, the melting state can be observed at a distance, directly pasted and used to visually display the overheating of the equipment.

$ 89.00

Immediate Temperature Response with Irreversible Color Changing Technology, Measurement accuracy +/- 1 ° C to +/- 4 ° C, Resistant to Oil, Water and Steam, Provides Long-term Temperature Record for Easy Paste and Preservation.

$ 96.00

Adopt irreversible color changing technology, accuracy +/- 1-4 ° C, oil and water resistance and steam resistance, provide four-grid temperature monitoring, size 23x45mm, 10 sheets each, easy to record temperature history for a long time.

$ 93.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted without complex installation and is suitable for temperature monitoring of a variety of electrical equipment.

$ 89.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted and used without complicated operation, and is suitable for temperature monitoring of various electrical equipment.

$ 91.00

Irreversible discoloration design to ensure permanent preservation of temperature records, 85 ° C accurate temperature measurement point with 2x2cm circular patch, Pressure sensitive adhesive layer to achieve firm paste and its own protective film to enhance durability

$ 89.00

Irreversible Color change for long-term temperature recording; Resistant to oil, water and steam; Temperature accuracy is +/- 1 ° C below 100 ° C and +/- 1.5 ° C from 100 ° C to 154 ° C; Self-adhesive design for easy use and storage.

$ 93.00

The mechanical compression spring device is not easy to damage, the accuracy is up to 0.5HW, the film thickness 0.4-6 mm workpiece can be detected, and various Hardness values such as Brinell Rockwell can be obtained through the conversion table.

$ 477.00

With five Illuminant system, Color temperature coverage 2700K to 6500K, no need to warm up without flashing, automatic switching Illuminant and display the use time, low energy consumption without heating, support Metamerism function.

$ 403.00

With a unique discoloration temperature function, it can achieve white, red, and black color changes, with a rated temperature of 75 ° C, with stickers for easy pasting, and can record temperature change history.

$ 86.00

Precise control of ink layer thickness, the minimum Basis Weight unit is 0.01CC, and the usage of Spot Color inks is predicted by calculation, which is suitable for ink contrast and color concentration detection.

$ 332.00

Three-color discoloration technology implementation of white to red and then to black reversible change, Temperature Measurement range 65 ℃ to 75 ℃, with over-temperature warning and temperature history function, size 25 * 38mm easy to install.

$ 85.00

With unique discoloration and digital display function, it can change white to red, red to black three Color changes, temperature monitoring range of 75 ℃, can record over temperature history, with its own sticker for easy installation and use.

$ 86.00

Adopting three-color reversible discoloration technology, when the temperature reaches 75 ° C, it turns from white to red, and turns black when it falls back to record the over-temperature history. The size is 25 * 21mm, with stickers for easy installation, and the repeability can be used to monitor temperature changes.

$ 86.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
The film coater applies a conductive film onto transparent substrate test pieces.
This article introduces a method for uniformly coating conductive films on transparent substrates such as glass or plastic films using a film applicator.
The coating machine applies an anti-reflection coating on the surface of optical lenses.
A coating machine is a precision device used for depositing anti-reflection coatings on the surface of optical lenses. Based on the principle of light interference, it forms a thin film of specific thickness on the lens surface through physical or chemical methods to reduce light reflection and enhance light transmission performance.
UV aging test chamber for evaluating the discoloration degree of resin weather resistance
This article introduces the method of using a UV aging test chamber to examine the degree of weather-induced discoloration in resins.
High Pressure Accelerated Aging Tester Evaluation of Paint Resistance to High Temperature, High Humidity, and High Pressure Environments
This article introduces how a high-pressure accelerated aging test machine evaluates the durability of colored paint under high temperature, high humidity, and high-pressure conditions. The test machine simulates these conditions to accelerate the aging of the coating and observe whether issues such as discoloration or blistering occur.
Constant Temperature and Humidity Chamber Testing for Ink Environmental Adaptability
This article introduces the method of testing the environmental adaptability of ink using a constant temperature and humidity chamber. Ink is prone to issues such as adhesion, discoloration, or reduced adhesion when exposed to changes in temperature and humidity.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.
Application of Continuous Coating Machine for Lithium Battery Electrode Preparation in Electrode R&D
The laboratory continuous coater is a key piece of equipment in lithium battery electrode research and development, used to simulate mass production coating processes. By precisely controlling parameters such as coating speed, thickness, and tension, it helps researchers optimize slurry formulations and coating procedures.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.