Humidity and Heat Cycling Test Chamber

The damp heat cycle test chamber simulates alternating environments of high temperature and high humidity with low temperature and low humidity through a temperature and humidity controller, allowing samples to undergo periodic changes in temperature and humidity inside the chamber. This equipment is used to test the aging resistance, dimensional stability, and electrical characteristics of materials under alternating damp heat conditions. It is widely applied in environmental adaptability testing for products such as electronic components, coatings, and plastics.
Selection
When selecting a humidity and heat cycle test chamber, it is essential to consider the temperature and humidity range, fluctuation, and uniformity specified by the testing standards. Determine the internal chamber dimensions based on the size and capacity of the samples. Pay attention to whether the refrigeration method can meet low-temperature requirements. Ensure the equipment has program editing capabilities and safety protection devices. Additionally, consider the device's energy consumption and its compatibility with the available laboratory space.

Terms

Standards

Instruments

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 11482.00

With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.

$ 10401.00

Using French Taikang fully enclosed Compressor, equipped with multi-wing air supply circulation system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2-3% R.H, improve test accuracy and efficiency.

$ 7754.00

Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.

$ 12579.00

Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2-3% R.H, with 100 sets of program capacity and RS-232/485 communication function.

$ 12402.00

Temperature range -20~ 150 ℃, humidity control 30~ 98% R.H., stainless steel liner and ultra-fine Glass insulation cotton, equipped with independent over-temperature protection and multi-layer conductive film observation window to ensure stable and reliable testing.

$ 7771.00

Temperature range -70~ 150 ℃, humidity uniformity +/- 2% -3% R.H., using multi-layer conductive film observation window and solid state relay control to ensure stable and reliable test environment.

$ 13225.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., with 100 program capacity and RS-485 communication function, support long-term stable operation.

$ 8287.00

With -40~ 150 ℃ wide temperature control and 30~ 98% humidity range, using French Taikang Compressor and multi-wing air supply circulation, high temperature and humidity uniformity, support 100 groups of program editing, improve test efficiency.

$ 14112.00

Temperature range -20~ 150 ℃ and humidity control 30~ 98% R.H., using PID control and solid state relay to ensure stability, multi-layer Glass observation window frost-proof design, support a variety of safety protection functions.

$ 6189.00

Temperature range -40~ 150 ℃, humidity control 30~ 98% R. H, Temperature Uniformity ≤ +/- 2 ℃, using PID control solid state relay and steam boiler humidification to ensure stable and reliable operation.

$ 12579.00

Temperature range -70~ 150 ℃, humidity uniformity +/- 2% -3% R.H., multi-layer conductive film observation window anti-frost design, equipped with independent over-temperature protector to ensure safe operation of the equipment.

$ 9384.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.